Page 4
Disclaimer: Spectrum Camera Solutions LLC makes no representations or warranties with respect to the contents hereof. Further, Spectrum Camera Solutions LLC reserves the right to revise this publication and to make changes in the content hereof, without obligation to notify any person or organization of such revision or changes.
Table of Contents Legal Notices and Revision History Inside front cover Page DESCRIPTION MODEL MATRIX LABELS STANDARDS AND CERTIFICATIONS DOCUMENT SYMBOLS HOW TO USE THIS MANUAL GENERAL SAFETY AND OPERATING INFORMATION 12-14 SPECIFICATIONS 15-17 INSTALLATION 18-24 DIMENTIONAL GENERAL ASSEMBLY HARDWARE BOM DISMANTLING &...
The “D” Series includes a full range of Stainless Steel or Anodized Aluminum camera stations specifically designed for Hazardous Area Applications. Spectrum’s D Series is the first Class I Division 1 rated dome style explosion proof housings, and utilizes the most robust and advanced camera technologies available. The D Series was designed with the integrator in mind and offers features never before seen in current camera systems.
1= (S) Stainless Steel 316L Housing C= Internal Equipment Part Number from Manufacturer*** BD= Optional Breather drain model**** *Internal components and D Series must be approved by Spectrum **Internal Equipment Manufacturer Code below ***Must be approved and verified by Spectrum ****Models supplied with Breather Drains will have IP66 ingress protection level CODE “XX”...
STANDARDS & CERTIFICATIONS STANDARDS- The equipment is manufactured in accordance with the IECEX scheme, the ATEX Directive 2014/34/EU and with the following standards : IEC 60079-0:2011 IEC 60079-1:2014 IEC 60079-31:2013 IEC 60529:2013 EN 60079-0:2012 + A11:2013 EN 60079-1:2014 EN 60079-31:2014 EN 60529:1991 + A1:2000 + A2:2013 ANSI/ISA 60079-0:2013 ANSI/UL 60079-1:2015...
DOCUMENT SYMBOLS The following symbols are used throughout this manual to alert users to potential hazards or important information. Failure to heed the warnings and cautions listed herein can lead to injury and equipment damage. Symbol Label Description Consists of conditions, practices, or procedures that WARNING: must be observed to prevent personal injury and/or equipment damage.
How to use this Manual General Manual: This manual is intended to be used in conjunction with installed equipment manual from internal equipment manufacturer. Note: In the event of a conflict between the requirements of this general installation manual and the internal equipment manual, the safety and installation procedures described in this manual shall take precedence.
General Safety and Operating Information: General safety and operating information applicable to electrical equipment installed within hazardous locations. This information must be understood by all persons installing, using, or maintaining the electrical equipment. This information is designed to aid personnel in safe installation, operation, and maintenance of the "D"...
Page 13
• Do not use chemicals, caustic agents, or aerosol cleaners. • Use a clean cloth dampened with pure water for cleaning. • Use only accessories that comply with the technical specification of the product. These can be provided by Spectrum or a third party. 105607312018 D201-x-Q6055-E INSTALLATION MANUAL REV-1...
Page 14
General Safety and Operating Information: Installation: The installation must be realized in accordance with IEC/EN 60079-14 and/or in accordance with the national requirements. This equipment must be installed and used only by qualified personnel, having knowledge concerning electrical equipment for use in potentially explosive areas containing gas and/or dust.
II 2 G Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, IP66 II 2 D Ex tb IIIC T85°C Db Ta = -20°C to +55°C, IP66 ELECTRICAL REQUIREMENTS of Model- D201-S-Q6055-E-BD POWER CAMERA CONSUMPTION: TYPICAL 16W, MAX 60W...
Page 16
D201-S-Q6055-E-BD Series Casing Material Specifications 316L STAINLESS STEEL 62lbs NOTE: Spectrum Camera Solutions, LLC is NOT responsible for any misuse or improper installation of product, assumes no liability for special or consequential damages caused by use or misuse or improper installation of its products sold and assumes no liability for injury from use or misuse or improper installation of its products or attached products.
Page 17
WIRING ENTRIES Conduit Entries are M20 x 1.5 Use appropriate Adapter With Nylon Washer or O-ring to keep ingress protection CAUTION: Ensure the Ethernet cable is disconnected from power source prior to wiring to the terminal block 105607312018 D201-x-Q6055-E INSTALLATION MANUAL REV-1...
INSTALLATION Ensure that power is off before attempting to connect and wire the camera 1. Use supplied M6 Hex tool to unscrew bolts and lock washers supplied on camera Figure 1. wall bracket installation 2. Make sure threads on camera and M10x 1.5 are free of dirt and debris. Place mount on camera and align holes and tighten bolts 3.
Page 19
INSTALLATION 4. Use supplied M5 supplied Hex tool to loosen D1005 terminal cap by turning counterclockwise Figure 2. Removing D1005 terminal cap 5. Set D1005 terminal cap in safe place 6. Route cable(s) into D1006 terminal housing junction box through user-supplied cable gland and seal using the recommended gland installation practices.
Page 20
INSTALLATION Figure 3. Conduit Entries are M20 x 1.5 Use appropriate Adapter With Nylon Washer or O-ring to keep ingress protection Example of CMP M20 to 3/4NPT adapter with Nylon Washer Figure 4. CAUTION: Ensure the Ethernet cable is disconnected from power source prior to wiring to the terminal block 105607312018 D201-x-Q6055-E INSTALLATION MANUAL REV-1...
Page 21
INSTALLATION 7. Connect the wiring using installer supplied small screw driver to push the open terminal block contact. Insert wires and remove screw driver. Adhere to local electrical codes/laws. Table 1. Power Connection To "D" Series Camera TERMINAL NUMBER WIRE Position - 1 White-Orange Position - 2...
Page 22
INSTALLATION 8. In addition to the internal ground connection, this equipment is also provided by an external secondary ground connection. Both must be connected for the internal ground the section must be equal to the active conductors. The external ground can receive a wire of 4 mm. The user/installer must connect the internal and external earthing before powering.
Page 23
INSTALLATION 9. Ensure threads on D1005 terminal cap and D1006 Terminal housing are free of dirt and debris. 10. Ensure gasket is free of dirt and debris 11. Reinstall D1005 terminal cap using supplied M5 supplied Hex tool to tighten by turning clockwise until hand tight and gasket is seated Figure 7.
Page 24
INSTALLATION 13. Remove Protective film after installation. If protective film is not removed in timely manor damage to dome is likely to occur with UV exposure 14. Apply power. For internal equipment startup procedures, setting changes, and troubleshooting guides reference the camera manufacturer’s manual included with the "D" Series Cameras. If the included copy is lost please contact https://www.spectrumcamera.com/support or To obtain...
For more information about the server report, see the product´s setup pages or contact Spectrum support. The battery should not be replaced unless required, but if the battery does need replacing, contact Spectrum support at www.spectrumcamera.com/support for assistance or To obtain...
Page 34
EU Type Examination Certificate (FM18ATEX0057X - 0) demonstrated with reference to the following documentation: Quality Assurance Notification FM17ATEXQ0099 Hubert Lee Rice II Date: August 29, 2018 Doc No. 100108292018 2014/34/EU Spectrum Camera Solutions, LLC 8935 Almeda Genoa Rd. Houston, TX 77075...
Page 35
EU Type Examination Certificate (FM18ATEX0057X - 0) demonstrated with reference to the following documentation: Quality Assurance Notification FM17ATEXQ0099 Hubert Lee Rice II Date: August 29, 2018 Doc No. 100108292018 2014/34/EU Spectrum Camera Solutions, LLC 8935 Almeda Genoa Rd. Houston, TX 77075...