12x8 COMBI SUMMERHOUSE V7
BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY
- Check the pack and make sure you have all the parts listed.
- When you are ready to start, make sure you have the right tools at hand (not supplied)
including a Phillips screwdriver, Stanley knife, wood saw, step ladder and drill with 2mm
bit.
- Ensure there is plenty of space and a clean dry area for assembly.
TIMBER
As with all natural materials, timber can be a ected during various weather conditions.
For the duration of heavy or extended periods of rain, swelling of the wood panels may
occur. Warping of the wood may also occur during excessive dry spells due to an interior
moisture loss. Unfortunately, these processes cannot be avoided but can be helped. It is
suggested that the outdoor building is sprayed with water during extended periods of
warm sunshine and sheltered as much as possible during rain or snow.
Our buildings are pre treated with a water based treatment**; this only helps to protect
the product during transit and for upto 3 months against mould. To validate your
guarantee and ensure longevity of the product, it is ESSENTIAL the building is treated
with a wood preserver within the rst three months of assembly and thereafter in
accordance with the manufactures recommendations. Care must be taken to ensure
the product is placed on a suitable base.
BUILDING A BASE
When thinking about where the building and base is going to be constructed:
Ensure that there will be access to all sides for maintenance work and annual
treatment.
Ensure the base is level and is built on rm ground, to prevent distortion. Refer to
diagrams for the base dimensions, The base should be slightly smaller than the external
measurement of the building, i.e. The cladding should overlap the base, creating a run
o for water. It is also recommended that the oor be at least 25mm above the
surrounding ground level to avoid ooding.
TYPES OF BASE
- Concrete 75mm laid on top of 75mm hard-core.
- Slabs laid on 50mm of sharp sand.
Whilst all products manufactured are made to the highest standards of Safety and in
the case of childrens products independently tested to EN71 level, we cannot accept
responsibility for your safety whilst erecting or using this product.
Refer to the instructions pages for you speci c product code
Please retain product label and instructions for future reference
x2
All building's should be
erected by two adults
For ease of assembly, you
MUST pilot drill all screw
holes and ensure all screw
heads are countersunk.
2mm Drill bit
**Protim Aquatan T5 (621)**
Your building has been treated with Aquatan.
Aquatan is a water-based concentrate which is diluted with water, the building as been treated by the correct
application of Aquatan solution and then allowed to dry.
Aquatan is a decorative nish to colour the wood, which is applied industrially to timber fence panels and
garden buildings.
Aquatan undiluted contains: boric acid, sodium hydroxide 32% solution, aqueos mixture of sodium dioctyl
sulphosuccinat and alcohols: 2, 4, 6-trichlorophenol.
For assistance please contact customer care on: 01636 880514
Mercia Garden Products Limited,
Sutton On Trent,
Newark,
Nottinghamshire,
NG23 6QN
www.merciagardenproducts.co.uk
Winter = High Moisture = Expansion
Summer = Low Moisture = Contraction
CAUTION
Every e ort has been made during the
manufacturing process to eliminate the
prospect of splinters on rough surfaces of the
timber. You are strongly advised to wear gloves
when working with or handling rough sawn
timber.
P 1

Advertisement

loading

Summary of Contents for Waltons 12x8 COMBI SUMMERHOUSE V7

  • Page 1 All building’s should be Winter = High Moisture = Expansion erected by two adults Summer = Low Moisture = Contraction 03LBRO1208-V7 12x8 COMBI SUMMERHOUSE V7 BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY For ease of assembly, you CAUTION MUST pilot drill all screw Every e ort has been made during the - Check the pack and make sure you have all the parts listed.
  • Page 2 03LBRO1208-V7 Please retain product label and instructions for future reference Overall Dimensions: Width =2806mm Depth = 2510mm Height = 2146mm Base Dimensions: Width = 3688mm Depth = 2439mm Before assembly please make sure you have a suitable base ready to erect your building Roof Under Roof...
  • Page 3 Please retain product label and instructions for future reference Fixing kit cont.. Nail Bag *This building can be built with the shed on the LEFT hand side. Follow the PI-02-0352 same steps but be aware to position panels to the opposite side.* 70mm Screw x 13 2x Door Handles Step 2...
  • Page 4 Please retain product label and instructions for future reference Step 3b Step 5 Fit the mortice lock (No. 42) into Fix the side of the short panel (No. 4) the recess and x in place with the screws against the side of the short window panel provided.
  • Page 5 Please retain product label and instructions for future reference Step 7 Step 9 Fix the Left Gable Top (No. 21) in place Before xing the internal panel in position, x the Right Gable Top (No. 20) in place slotting the groove of the boarding on the gable into the tongue of the side panels slotting the groove of the boarding on the (No.
  • Page 6 Please retain product label and instructions for future reference Please retain product label and instructions for future reference Step 11 Step 13 Place the Door Panel/ Front Window Fix the Double Boarded Gable Top (No. 19) Panel (No. 1/No. 2) onto the in place slotting the groove of the boarding assembly between the Short Window Panel on the gable into the tongue of the Side...
  • Page 7 Please retain product label and instructions for future reference Step 17a Step 15 Place the Roof Panels (No. 11) onto the top Place the Assembled Storage Door panel of the building. Allign the 2 Roof Panels (No. 6) against the end of the Sorage Gable Sides (No.
  • Page 8 Please retain product label and instructions for future reference Step 18b Step 17c Continue to x the building into place by Screw through panel into the alligned screwing through the panel into the oor Roof bearers as shown in the diagram. making sure to screw into the oor bearers.
  • Page 9 Please retain product label and instructions for future reference Step 22 Step 20 Fix the Cover Trims (No. 23, 2x No. 24, Cut the Felt (No. 34 ) into 3 sheets and lay No. 25, No.26, No.27 and 2x No. 28) into onto the roof.
  • Page 10 Please retain product label and instructions for future reference Step 23 Step 21 Attach two Turn Buttons (No. 43) to the Storage To x the lock to the Shed Door, rst x the Door Doorat the top and bottom of the door. Using Blocks (No.