Page 1
SERVICE BULLETIN SB-6-HGB-P Replaces SB-6-HGB-N II2G HGB-509 / HGB-510 / HGB-609 FLUID REGULATOR DESCRIPTION Manually adjusted or remote air pressure controlled, these fluid regulators can provide material at constant pressure for one or two spray guns, using stainless steel ball valve and spring, “Perlast” valve seat.
Page 2 SB-6-HGB-P SAFETY WARNINGS Important: Read and follow all instructions recommendations and safety precautions before using this equipment. FIRE AND EXPLOSION • Always wear eye protection when spraying or cleaning the equipment. Solvents and coating materials can be highly flammable or combustible, especially when sprayed .
Order Number Description Qty. HGB-404-1 Adjusting key HGB-28 Cover S-1309-H For HGB-509-5-R38 or 609-x-R38, Screw M5 * 16 S-1330-H For HGB-510-R1, R2 & R4, or (CO), Screw M5 * 25 HGB-408-H Adjusting screw assembly HGB-7 Adjusting nut HGB-403-H Stem kit HGB-13-H Spring for diaphragm for HGB-509-5-R38 or HGB-609-5-R38.
Periodically clean exterior of regulator with solvent soaked rag. REPLACEMENT OF PARTS Relieve the line pressure before servicing for pneumatic model (HGB-510). For manual model HGB-509 & 609, Relieve spring forces by unscrewing the adjusting screw rep 4 at the maximum OPERATION (FIG A).
EC DECLARATION OF CONFORMITY We, Finishing Brands, as the manufacturer of the fluid regulators HGB-509, HGB-510, HGB-609, declare under our sole responsibility, that the equipment to which this document relates is in conformity with the following standards or other normative documents : EN 292-1 PARTS 1 &...