16. Perform another test print and check the reference deviation.
17. Repeat the adjustment until the reference line falls within the specified range.
18. Tighten the adjustment lock screw.
13. Press the Drawer Eject Button and slide out the
drawer.
4348U010AA
14. Open the Right Door.
D E
15. Loosen the adjustment lock screw D and turn
screw E to make the adjustment.
NOTE
• Do not damage the passage surface of the Right
Door.
4348U011AA
• If width A is wider than the specified range:
Turn screw E counterclockwise.
4002U106AA
• If width A is narrower than the specified range:
Turn screw E clockwise.
4002U105AA
D-12