4-5-2 Checking Outdoor Controller
1. Making sure the wire connections.
Caution! When you remove PBA, you have to check DC link Voltage. After Power off, DC link Voltage is so high!
2. Checking AC(220~240V) line
3. Checking DC voltage on each point
RJ040F2HXEA/RJ050F2HXEA
Item
Measuring point Normal value
DC LINK
CE101 voltage
Main control 15V
CE154 voltage
Main control 12V
CE157 voltage
Main control 5V
CE158 voltage
Main control 3.3V
CE155 voltage
RJ100F5HXEA MAIN PCB
Item
Measuring point
12V
CN12
5V
CN32 3-4PIN
RJ100F5HXEA INVERTER PCB
Item
Measuring point
DC LINK
PFCM 33/32
Main control 15V
refer to picture
Main control 12V
refer to picture
Main control 5V
refer to picture
Main control 3.3V
refer to picture
4. Checking PFCM
Check Resistance between R and S
RJ040F2HXEA/RJ050F2HXEA
s
R
RJ060F3HXEA/RJ070F4HXEA/RJ080F4HXEA
s
R
RJ100F5HXEA
Samsung Electronics
AC220V -> 305~310Vdc
14.5V - 15.5V
12V - 15V
4.75V - 5.25V
3.0V - 3.6V
Normal value
DC11~13V
DC4.75~5.25V
Normal value
300~320V
DC 14~16V
DC 11~13V
DC 4.75V - 5.25V
DC 3.0V - 3.6V
Measuring point
Resistance R - S
RJ060F3HXEA/RJ070F4HXEA/RJ080F4HXEA
Item
Measuring point
DC LINK
CE001 voltage
Main control 15V
CE110 voltage
Main control 12V
CE108 voltage
Main control 5V
CE106 voltage
Main control 3.3V
CE105 voltage
Normal value
over the hundreds
Normal value
AC220V -> 305~310Vdc
14.5V - 15.5V
12V - 15V
4.75V - 5.25V
3.0V - 3.6V