Connection for providing the air needed for combustion:
In airtight buildings there can be reduction in the oxygen content of the room in which the stove is set up; it must
therefore be ensured that there is adequate ventilation. The stove unit type Aqua 187.19-WT therefore offers you
the possibility of drawing in the air needed for combustion from outside. The stove can then be operated without
having to depend on the air within the room. In order to do this the air from outside that is needed for combustion
is supplied by means of a flexible pipe attached to the socket for the pipe (10). It is possible for you to change the
position of the pipe socket to the left, right or rear of the stove unit. The end of the pipe carrying the air must be
located in the open air, or in a well ventilated room situated within the building. Operation of the stove unit in
connection with an air conditioning and ventilation system is permitted. When installing the stove unit in
connection with an automatic air conditioning and ventilation system the end of the pipe supplying the air must not
be located in a room which is connected to this system.
The amount of fuel and adjustment of the air intake control:
Lighting, and heating the appliance up: see sections 11 in the instructions for use of the stove.
Use the gloves provided to protect you against the heat when operating the air intake control.
Before every addition of fuel, the air intake control is to be closed completely.
Fuels
Amount of fuel
Chopped wood
Wood briquettes:
Lignite
briquettes:
Tip for burning wood: Every time the stove is lit leave the appliance in the 'open' position until
the fuel is burning well (around 10 minutes). This time can vary somewhat depending on the
amount of draught and the pressures involved.

Specification plate:

Typenbezeichnung:
Herstellnummer:
Wärmeleistungsbereich:
Nennwärmeleistung
Wärmeleistung/Wärmetauscher
Zugelassener Brennstoff:
Staub bez.auf % O
Prüf Nr. VKF:
Abgastemperatur :
Mindestabstände
zu brennbaren Bauteilen:
Prüfstellenkennziffer: 1015 / Prüf Nr.30-11150
Lesen und befolgen Sie die Bedieungsanleitung!
Mehrfachbelegung des Schornsteins ist zulässig
Prüf. Nr.
Stove unit Aqua 187.19-WT / EN 13229
Testing code : 1015
5 -6 pieces of wood
(approx 4 -4,5 kg) or
2 wood briquette (4 kg)
5 -6 briquettes
HAAS + SOHN OFENTECHNIK GMBH
URSTEIN NORD 67
Kamineinsatz Bauart: EN13229 / Zeitbrandfeuerstätte
Holz, Holzbrikett nach -DIN 51731, Braunkohlebrikett
mg/Nm³
2: 30
Wirkungsgrad:90,5%
NOx: 106 mg/Nm³
seitlich:
hinten:
vorne im Strahlungsbereich:
Betriebsdruck max. 3,0bar
Primary air: air intake control (6)
For approximately 10 minutes: open
(handle to the left)
open
A-5412 PUCH
166°C
Anbringungsjahr
2011
Inspection no.: E 30 - 11150
4
Art. Nr.0618719009033
Secondary air (7)
187.19-WT
1103187901650
5,1- 17,4 kW
17,0 kW
10,8 kW
CO:0,05%
HC: 23 mg/Nm³
40 cm
40 cm
80 cm
V12 E30
open
position 1