elsner elektronik WL610 Technical Specifications And Installation Instructions

Ventilation unit for air extraction and recirculation

Advertisement

Quick Links

EN
WL610
Ventilation Unit
for air extraction and recirculation
Technical specifications and installation instructions
Interior view
Elsner Elektronik GmbH Control and Automation Engineering
Herdweg 7
D – 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0
Germany
Fax
+49 (0) 70 56 / 93 97-20 www.elsner-elektronik.de
info@elsner-elektronik.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WL610 and is the answer not in the manual?

Questions and answers

Summary of Contents for elsner elektronik WL610

  • Page 1 WL610 Ventilation Unit for air extraction and recirculation Technical specifications and installation instructions Interior view Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D – 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0 info@elsner-elektronik.de Germany +49 (0) 70 56 / 93 97-20 www.elsner-elektronik.de...
  • Page 2: Technical Specifications

    Functions: • Air extraction mode. Please pay attention to an adequate opening for supply air of approx. 12 240 mm² per WL610 (e. g. two Supply Air Units WFL or equal window opening) • Recirculation mode for heat gain: Warm air from the ridge is spread in the whole room •...
  • Page 3 For an additional charge, the panel can be delivered already in the dimensions you need. A different panel thickness is also possible upon request (panel thickness 24-40 mm). Ventilation Unit WL610 • Date of issue: 25.05.2011 • Technical changes reserved. Errors reserved.
  • Page 4 RAL 9006 White Aluminium • RAL 9007 Grey Aluminium All other RAL colours are also available at an additional charge (also two-coloured in- side – ouside). Ventilation Unit WL610 • Date of issue: 25.05.2011 • Technical changes reserved. Errors reserved.
  • Page 5: Installation And Commissioning

    The device is exclusively intended for appropriate use. With each inappropriate change or non-observance of the instructions for use, any warranty or guarantee claim will be void. Ventilation Unit WL610 • Date of issue: 25.05.2011 • Technical changes reserved. Errors reserved.
  • Page 6: Notes On Wireless Equipment

    So that no water can penetrate through the air outlet on the outside when it is raining, or due to other weather influences, the panel must be mounted such that the outlet fac- es downwards. Ventilation Unit WL610 • Date of issue: 25.05.2011 • Technical changes reserved. Errors reserved.
  • Page 7: Device Construction

    Fig. 2 Outlet cable voltage supply (not visible when mounted) Ventilation unit with roll ventilator, flap and drives Screws M5/Allen Screws M3/Allen Inside cover hood Lock hole Ventilation Unit WL610 • Date of issue: 25.05.2011 • Technical changes reserved. Errors reserved.
  • Page 8: Maintenance

    Maintenance and cleaning inside the device must only be car- ried out by a competent electrician. The device must be separat- ed from power supply then (e.g. deactivate or remove fuse). Ventilation Unit WL610 • Date of issue: 25.05.2011 • Technical changes reserved. Errors reserved.