If residual heat is present, "H" will be dis-
played on all other heater displays.
The hob control will then go into S-Mode.
At the same time a buzzer sounds. After
10 minutes the buzzer will stop.
If there is no erroneous operation
present, both the visual and the audible
signals will disapear.
Over Temperature Switch-Off
Due to the controls being very close to
the heater in the middle of the front of
the hob, it can occur that an incorrectly
placed pot is not sensed by the sensor
safety cut-off therefore heating up the
hob to a very high temperature. This
makes the glass and the buttons dan-
gerous to touch. To prevent the hob
control unit from damage, the controls
constantly monitor the temperature and
switch off if overheating occurs.
This will be indicated by the letter "t" in
the heater display until the temperature
decreases.
Once the temperature has dropped,
the "t" in the heater display will disap-
pear and the hob control unit will revert
back into S-Mode. This means that the
user can reactivate the appliance by
pressing
.
Operating Time Limitations
The hob control unit has a limitation on
the operating time. If the heat setting for a
heater has not been changed for a certain
time, the heater will switch off automatical-
ly. A "0" will be displayed for 10 seconds,
however there may be some residual heat
present. The limit of the operating time de-
pends on the selected heat setting.
Selected power
level
1
2
3
4
5
6
7
8
9
After a heater automatically switches off ,
as described above, the heater can be
used and the maximum operating time
for this heat setting will be applied.
Residual Heat Functions
After all cooking processes, some heat
will be stored in the vitroceramic glass
called residual heat. The appliance can
calculate roughly how hot this glass is.
If the calculated temperature is higher
than +60°C, then this will be indicated
in the corresponding heater display for
as long as the calculated temperature
remains above +60°C, even after the
appliance has been switched off .
The residual heat indicator has the low-
est priority and is overwritten by every
other display value, including during
safety switch-off and the displaying of an
error code. When voltage is supplied to
the hob after a power interruption, the re-
sidual heat display indicator will fl ash. If
a heater had a residual heat of greater
100
EN
MAX. WORKING
TIME (in hours)
10
5
5
4
3
2
2
2
1

Hide quick links: