Observed   C ondition  
1  
Sprinkler   w ill   n ot  
open   e lectrically  
 
 
Mirage   M -­‐125   /   M -­‐115   O perating   &   M aintenance   I nstructions  
 
Possible   C ause  
Dirt   o r   d ebris   i s  
clogging   t he   s olenoid  
valve   s eat.  
 
The   s upply   c urrent  
to   t he   s olenoid   i s  
inadequate.  
 
 
De-­‐pressurize   t he  
!  
mainline   o r   s ub-­‐
lateral   p iping  
before   a ttempting  
the   l ast   t wo  
possible   r oot  
causes  
 
The   s olenoid   i s  
defective  
 
 
 
The   p lunger   i n   t he  
solenoid   i s   s tuck   i n  
the   " up"   p osition  
 
Troubleshooting  
Remove   t he   s olenoid   a nd   i nspect  
the   f ilters   f or   d ebris.     C lean   a nd  
reassemble.  
 
Verify   2 4   V AC   i s   b eing   r eceived  
from   t he   c ontrol   p roduct   u sing   a  
multi-­‐meter.     C onduct   a n   O hms  
check   t o   v erify   w ire   c ontinuity.  
 
 
 
 
 
 
 
 
 
An   o hms   t est   o n   t he   s olenoid  
indicates   o hms   r esistance   i n  
excess   o f   7 5   o hms.     R eplace   t he  
solenoid.  
 
After   i nspection   a nd   c leaning,  
operate   t he   s olenoid   e lectrically.    
If   i t   r emains   s tuck,   r eplace   t he  
solenoid.  