zewa 11110 Instruction Manual
Hide thumbs Also See for 11110:

Advertisement

Quick Links

0482
Infrared Thermometer
Instruction Manual
Zewa, Inc
Manual Version: 1.0
Date of Issue: 2020/06/05

Advertisement

Table of Contents
loading

Summary of Contents for zewa 11110

  • Page 1 0482 Infrared Thermometer Instruction Manual Zewa, Inc Manual Version: 1.0 Date of Issue: 2020/06/05...
  • Page 2 All statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Zewa, Inc.. reserves the right of final interpretation of this document. Introduction Thank you for purchasing this Infrared Thermometer.
  • Page 3: Table Of Contents

    Contents Unpacking Check.....................1 Package Contents..................... 1 Safety Precautions....................2 Warning......................3 Symbols......................4 Body Temperature Basics................5 Product Description..................6 Features......................7 Product Structure....................8 Display description..................8 Sounds and backlight instructions..............9 Measurement Process..................15 Replacing Batteries..................16 Cleaning and Disinfection................17 Maintenance....................19 Troubleshooting.....................
  • Page 4: Unpacking Check

    In case of any damage or operation problem, please contact the dealer or contact Zewa directly. You will need the following information when making your claim: Device model, serial number, purchase date, and your contact information and address.
  • Page 5: Safety Precautions

    Safety Precautions Read the following precautions carefully before using the thermometer. Attention  Take care of the temperature probe lens, which is fragile.  Dispose used batteries with care. To protect the environment, you are recommended to send the used batteries to a designated collection point.
  • Page 6: Warning

    operating temperature range of the thermometer.  Risk of pollution! The user is recommended to send the overdue thermometer to local garbage disposal site or send it back to us.  2 AAA batteries of 1.5V are the only replaceable accessories of the thermometer.
  • Page 7: Symbols

    Symbols Symbol Description Type BF applied part. Attention must be paid. The action is prohibited. Information about the manufacturer. Date of manufacture. Consult the instructions for use. This product complies with the MDD93/42/EEC requirements. Waste electrical materials should be sent to a dedicated collection point for recycling.
  • Page 8: Body Temperature Basics

    Body Temperature Basics You can take a body temperature on the forehead, in the ear canal, under the armpit, in the mouth, or in the anus. The temperature measured at different parts of the body may differ slightly. Body Part Normal Temperature Range Forehead 36.1°C–37.5°C / 97.0°F–99.5°F...
  • Page 9: Product Description

    Product Description Overview The Infrared Thermometer measures the human body or an object temperature based on the infrared energy emitted by the forehead or an object (such as milk and water). You can quickly get measurement results after pointing the temperature probe to the target. Structure The thermometer consists of a shell, an LCD, buttons, a beeper, an infrared temperature sensor, and a Microprocessor.
  • Page 10: Features

    Features 1. Good safety ● Passive infrared receiving technology ● Non-contact measurement, preventing cross-infection 2. Easy operation ● Handheld design, easy operation ● One-click automatic temperature measurement 3. Quick response 1-second measurement 4. High accuracy ● Advanced infrared temperature sensor, with high sensitivity ●...
  • Page 11: Product Structure

    Product Structure 1、IR sensor 2、Power-on button / Measure button 3、Battery cover 4、LCD display 5、Mute / Un-mute button 6、Mode button 7、Celsius / Fahrenheit Switch button 8、Handgrip Display description 1. Object temperature mode 2. Forehead temperature mode 3. Temperature unit (˚C / ˚F) 4.
  • Page 12: Sounds And Backlight Instructions

    Sounds and backlight instructions Range Sounds Backlight Forehead temperature A long beep Green 34.9℃-37.5℃/94.8℉-99.5℉ 3 short double beeps 37.6℃-42.2℃/99.6℉-108.0℉ Object temperature A long beep White 0℃-100℃/32.0℉-212.0℉ Note: When the temperature is between 34.9°C/94.8℉ and 37.5°C/99.5℉, there will be a long beep and a green backlight. When the temperature is between 37.6°C/99.6℉...
  • Page 13 Display and Operating Instructions Operating Instructions/ Screen Display Description Displayed State Measuring Forehead temperature In a power-off state, point the IR sensor to the center of the forehead. Move the thermometer towards the forehead. For effective measurement, the distance See the table in the between the thermometer “Sounds and Backlight and the forehead must be...
  • Page 14 Operating Instructions/ Screen Display Description Displayed State Out of the measuring range display In Object mode, a temperature reading of more than 100ºC (212.0ºF) A long beep and a green In Forehead mode, a backlight for 3 seconds. temperature reading of more than 42.2ºC (108.0ºF) In Object mode, a...
  • Page 15 Operating Instructions/ Screen Display Description Displayed State Switching between forehead temperature and object temperature In a power-on state, press the Mode button to switch between forehead Silent temperature ( ) and object temperature ( Switching between mute and un-mute In a power-on state, press symbol is the Mute/Un-mute button displayed in Un-mute...
  • Page 16 Operating Instructions/ Screen Display Description Displayed State Recall 20 memories In a power-on state, press Press the Measure button and hold the Mode button to return to the for more than 2 seconds. measurement interface. "F-1" is displayed. Press the ºC/ºF or the button, 1 will be shown, followed by the recorded reading.
  • Page 17 Operating Instructions/ Screen Display Description Displayed State Fever alert threshold settings When "F-1" is displayed, Press the Measure button press the Mode button. to return to the Then "F-2" is displayed. measurement interface. Press the ºC/ºF or the button. The fever alert threshold is displayed.
  • Page 18: Measurement Process

    Operating Instructions/ Screen Display Description Displayed State When the battery voltage is lower than 2.5V ± 0.1V, the low battery symbol Silent will appear on the display. Please replace the batteries. Power-off In any mode, if there is no operation in 10 seconds, the thermometer will power off automatically.
  • Page 19: Replacing Batteries

    3. After a measurement ■ After each measurement, clean the thermometer with a dry soft cloth, and put the thermometer in a dry and well-ventilated place. ■ The thermometer automatically powers off if it is not used in 10 seconds. Notes: (1) The thermometer is suitable for an indoor environment without strong air convection between the thermometer and the target.
  • Page 20: Cleaning And Disinfection

    AAA batteries into the compartment correctly. If the low-battery symbol is displayed on the screen, replace the batteries. Make sure that the batteries are installed correctly. Otherwise, the thermometer may be damaged. Batteries of a same type should be used. Dispose the used batteries in accordance with the local environmental policies.
  • Page 21 temperature probe with a cotton swab. Wipe the thermometer body with a slightly damp soft cloth. Keep water off the lens during the cleaning process. Otherwise, the lens may be damaged. The lens may be scratched if it is cleaned with a piece of tissue paper, which might result in inaccurate readings.
  • Page 22: Maintenance

    Disinfect the thermometer body with a cloth slightly moistened with 75% medical alcohol. Do not use hot steam or ultraviolet radiation for disinfection. Otherwise, the thermometer may be damaged or quickly aged. Clean and disinfect the thermometer under the temperature of +10℃~+40℃(50℉-104℉), the relative humidity of 15%~85%RH (no condensation) and the barometric pressure of 86kPa~106kPa.
  • Page 23: Troubleshooting

    Troubleshooting Problem Possible Cause Solution Low battery the batteries. Change Polarities of the Make sure that the The thermometer batteries are reversed. batteries are installed fails to power on. correctly. The thermometer is Contact the manufacturer. damaged. The ambient Take a measurement temperature is lower under an ambient "Er1"...
  • Page 24: Specifications

    Specifications Product Name Infrared Thermometer Product Model 11110 (JPD-FR202) Power Supply Mode Internal power supply Operating Voltage DC 3V Battery Model AAA x 2 Operating Mode Continuous operating Display Segment LCD Measure time About 1 second Latency Time About 1 second Emissivity 0.95...
  • Page 25: Security Class

    The infrared thermometer has been tested and conforms to the standard ASTM E1965-98. ASTM laboratory accuracy requirements in the display range of 98°F to102°F (37°C-39°C) for skin IR thermometers is ±0.5°F (±0.3°C). Note that for mercury-in-glass and electronic thermometers, the requirement per ASTM Standards E667-86 and E1112-86 is ±0.2°F (±0.1°C).
  • Page 26: Emc Information-Guidance And Manufacture's Declaration

    EMC Information-Guidance and Manufacture’s Declaration CAUTION: ●The Infrared Thermometer needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided for in the ACCOMPANYING DOCUMENTS. ●Portable and mobile RF communications equipment can affect Infrared Thermometer.
  • Page 27 Guidance and manufacturer´s declaration – Electromagnetic immunity The Infrared Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the Infrared Thermometer should assure that it is used in such an environment. Immunity test Compliance Electromagnetic 60601...
  • Page 28 Recommended separation distance where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an Electromagnetic site survey,a should be less than the compliance level in each...
  • Page 29 JPD-FR202. b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM -for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING The Infrared Thermometer is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
  • Page 30: Warranty And After-Sale Service

    Warranty and After-Sale Service The device is under warranty for one year from the date of purchase. The batteries, the packaging, and any damage caused by improper use are not covered by the warranty. Excluding the following user-caused failures: 1.Failure resulting from unauthorized disassembly and modification. 2.Failure resulting from an unexpected dropping during application or transportation.
  • Page 32 Zewa, Inc. 12960 Commerce Lakes Dr. # 29 Fort Myers, FL 33913 www.zewa.com Toll Free Customer Service: 1-888-993-3592...

This manual is also suitable for:

Jpd-fr202

Table of Contents