Subject: ADR100 Getting
Started Guide
Revision: 2.2
Issue Date: 30/10/2018
Product names mentioned
herein are for identification
purposes only and may be
trademarks and/or
registered trademarks of
their respective companies.
© Copyright 2018
ALL RIGHTS RESERVED
Access-IS
18 Suttons Business Park, Reading
Berkshire, RG6 1AZ, United Kingdom
Tel: +44 (0) 118 966 3333
Web: www.access-is.com
Email: support@access-is.com
ADR100
Photo ID Reader
Getting Started Guide

Advertisement

Table of Contents
loading

Summary of Contents for Access Interfacing Solutions ADR100

  • Page 1 Subject: ADR100 Getting Started Guide ADR100 Revision: 2.2 Issue Date: 30/10/2018 Photo ID Reader Product names mentioned Getting Started Guide herein are for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. © Copyright 2018...
  • Page 2 Warnings This manual contains important information regarding the installation and operation of the ADR100 Photo ID Reader. For safe and reliable operation of the imager, installers must ensure that they are familiar with, and fully understand, all instructions contained herein.
  • Page 3: Table Of Contents

    Contents Overview ..........................4 Installation ......................... 5 Opening the box ....................... 5 Connecting the ADR100 to the host ................5 Mounting ........................6 Testing the device ....................6 Troubleshooting ......................7 Maintenance ......................8 Access-IS Document Reader Software ................9 Installing the software ....................
  • Page 4: Overview

    1. Overview The ADR100 Photo ID Reader captures a full-colour image of an ID card together with ultraviolet (UV) and, where the option is installed, infrared (IR) images. This device has been designed for indoor and outdoor use, under all lighting conditions and weather – overcast, bright sun, rain.
  • Page 5: Installation

    Windows XP or above. Note: The ADR100 is approved for use with a USB cable no longer than 3 m total length. If a longer cable is used, you should fit a DC EMC filter to the power supply. Please contact the Access-IS support team for details.
  • Page 6: Mounting

    2.3.1 Mounting points When mounting the ADR100, use four M4 screws (not provided) to mount the unit. From the base of the ADR100 (bottom of the plastic housing), the minimum insertion depth is 3 mm. The maximum insertion depth is 6 mm.
  • Page 7: Troubleshooting

    2.5 Troubleshooting If the ADR100 does not appear to be working, refer to the following table to help identify and resolve the problem. For further assistance, contact Customer Support (support@access-is.com). Alternatively, use the Contact Customer Support page on the Access-IS website.
  • Page 8: Maintenance

    2.6 Maintenance 2.6.1 Cleaning Clean the glass with a lint-free cloth. If the glass is dirty, wipe the glass with a lint-free cloth moistened with isopropyl alcohol or use an alcohol wipe. Do not use abrasive cleaners. 2.6.2 Storage Store the unit in its original box, at a temperature of 0°C to 60°C. Page 8 of 16 Copyright ©...
  • Page 9: Access-Is Document Reader Software

    The Access-IS Document Reader Software (ADRS) delivers an instant visual snapshot of document data, resulting in a more efficient and effective workflow. You can install the software before or after you connect the ADR100 to the host computer. For more information on how to configure ADRS, refer to the ADRS User Guide.
  • Page 10 Certificate Propagation service. This service may affect the RFID operation of Access-IS products with RFID functionality. If you only use devices without RFID, such as the ADR100 and OCR31x, please select No. If, in the future, you are planning to use an Access-ID RFID-enabled device, then please select Yes.
  • Page 11 If you do not use a smart card to unlock the host computer, you can safely disable the service. The web page that automatically opens provides more information on the Certificate Propagation service (https://www.technet.microsoft.com/en-us/library/ff404288). Click Yes to stop and disable the service, and then click OK. 10.
  • Page 12: Starting The Software

    Access-IS System Information Provides operating system information. 3.2 Starting the software 1. Connect the ADR100 to the host. See Connecting the ADR100 to the host (on page 5) for details. 2. Double-click the Access-IS Document Reader shortcut on the host's desktop.
  • Page 13 3.3.3 Document information If fitted with the IR option, the ADR100 reads the MRZ, if it is present on the document that you are scanning. Once read, the reader decodes the information and the details appear in the Document Information section on the Summary tab. If a colour image is captured, the software picks out the face from the image and displays this separately.
  • Page 14: Document Reader Software Status Messages

    Table 4: Document reader software status messages Message Description ADR100 is ready The ADR100 is connected to the host, powered and ready to read a document. Reading The ADR100 is acquiring images. Writing Multiple Image file The ADR100 is acquiring images and saving these to disk.
  • Page 15: Specifications

    A. Specifications Specification Details Dimensions (W x D x H) 106 mm x 79 mm x 86 mm Weight 285 g (excluding cable and power supply unit) Environmental Operating temperature: 0ºC to 50ºC Storage temperature: 0ºC to 60ºC Humidity: 0 to 95% non-condensing Body Black ABS Glass...
  • Page 16: Model Numbers

    B. Model numbers 1D/2D Model Bezel Visible barcode ADR100-A ADR100-B ADR100-AB ADR100-BB ADR100-AI ADR100-BI ADR100-ABI ADR100-BBI C. Document history Revision Date Description 02/2015 First issue. 03/2015 Content revisions. 12/2015 Download link update. 09/2016 Content revisions, addition of ADRS. 09/2018 Minor formatting changes.