3
Installation
Remove all packaging from the product before commencing installation. Ensure the circuit has been isolated from the 240V mains before
commencing work.
1. Choose a suitable mounting location. There must be adequate clearances in the wall/ceiling to accommodate the Draft-stopper and/or
ducting. Refer to section 2 for further information.
2. If ducting through the wall to the outside, refer to instructions in the wall duct kit. Note: the wall kit is available separately, please refer
to Optional Accessories section.
3. Time-delay module is available separately, please refer to Optional Accessories section.
4. Make a circular 110mm hole in the wall/ceiling.
5. Remove front cover / fascia by removing fixing screw and cap on the underside of the cover.
6. Remove draft-stopper if not required. Note that the draft-stopper (when fitted) has an effect on the airflow.
7. Make the electrical connections (as per Figures below).
Figure 1.
Fan
mounting
orientation
8. Ensure orientation of fan is with arrow pointing↑up.
9. Fix fan firmly to the wall with the 4 screws provided.
10. Replace front cover/fascia and tighten fixing screw. Replace cap.
11. Switch on and test function. Use a paper tissue held against fan inlet to verify suction.
4
Cleaning
The exhaust fan grill should be cleaned every 6 months to prevent dust build-up. Ensure the fan is switched off from the mains supply before
removing the fascia.
5
Optional Accessories
R621/4D – 100mm wall duct kit
EF100/150TD – Time delay module allows the fan to run for a set period, adjustable between 1 - 29 mins, after the switch has been turned off.
Disclaimers
1. This product must be installed and used as per these instructions. 2. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance. 3. This appliance is intended for household use and similar purposes. It is not suitable for use in an environment heavily laden with dust. Under
these conditions the life of the fan motor can be significantly reduced. 4. This product contains no serviceable parts and no attempt should be made to repair this product. If the product is faulty it
should be discarded. 5. This product must be cleaned periodically from dust and other contaminants with a damp cloth. Aggressive cleaning agents and solvents should never be used. 6. Airflows
listed in this product indicate the product performance. Refer to the BCA (Building Code of Australia), or similar, for the appropriate airflow required for a particular installation. 7. Ventilation
products must have an adequate source of external air to ensure correct performance. 8. Consideration must be taken in the installation of ducts to ensure that condensation that will form in the
duct will not run back in to the fan housing. 9. Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances. 10. This product
has been designed for domestic or similar uses and is not suitable for a commercial installation. 11. This product utilises intellectual property in the form of registered designs, trademarks, and/or
patents. Such intellectual property remains the property of HPM Legrand in all cases. 12. HPM Legrand reserves the right to modify the specification of this product at any time.
Warranty
HPM Legrand warrants this product for a period of 3 years from the date of purchase.
These goods come with guarantees that cannot be excluded under the Australian and
New Zealand Consumer Laws. You are entitled to a replacement or a refund for a major
failure and for compensation for any other reasonably foreseeable loss or damage.
You are also entitled to have the goods repaired if the goods fail to be acceptable quality
and the failure does not amount to a major failure. See the Warranty card enclosed with
this product for further details.
LS Switched Active
from wall switch
N Neutral
L Unswitched Active
(only used when
timer module is
fitted)
Cable entry
from rear
Cord entry from
side for plug and
lead (knock-out
provided)
Fixing screw
position of fascia
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
HPM Legrand Australia
1300 369 777
www.hpm.com.au
ABN: 31 000 102 661
Figure 2. Fan with timer module and light fitting
Active
Neutral
Connection from rear – bring mains wiring through
cable entry hole.
Connection from side (Fan only) – use twin flat core
(H03VV-H2) or circular core (H05VV-F) 2 x 0.75mm
and place under cable clamp provided.
HPM Legrand New Zealand
0800 476 009
www.hpm.co.nz
L
N
LS
2