6.4.4 Alarm Monitoring Configuration

Monitoring Function ON/OFF
In Configuration section on Modules page, click Alarm Control to Enable/Disable Monitoring Function.
Temperature, +12V/+5V Voltage Alarm Levels Management
By default, the temperature and voltage alarms are enabled. The check box, ☑, as shown in Figure 6-8, toggles the alarms.
When the check box is checked, (detection ON), the associated alarm is enabled, the text in the text box are always grey
and can not be changed. The default alarm parameters are shown in Figure 6-8, Table 6-4 below.
Table 6-4 Modules Page Alarms Threshold Parameters Instruction
Parameter
Temperature
+12V Input voltage
+5V Input voltage
May/2016 - Version 1.0
Units
HIHI
HI
°C
70
65
Vdc
13,5
-
Vdc
6
-
Technetix Group Limited
sales@technetix.com
AIMA3000.FRAS Product User Manual
Normal
LO
LOLO
-
0
-5
12
-
10,5
5
-
4,4
Figure 6-8
technetix.com
Threshold
Dead
changeable by
Band
user
2
N
0,2
N
0,1
N
Default Alarm
Enable
ON
ON
ON