technetix AIMA3000.FT5P Product User Manual

Forward transmitter - performance 1550 nm

Advertisement

Quick Links

AIMA3000.FT5P
1550 nm Forward Transmitter - Performance
Product User Manual
May/2016 - Version 1.0

Advertisement

Table of Contents
loading

Summary of Contents for technetix AIMA3000.FT5P

  • Page 1 AIMA3000.FT5P 1550 nm Forward Transmitter - Performance Product User Manual May/2016 - Version 1.0...
  • Page 2 AIMA3000.FT5P Product User Manual AIMA3000.FT5P 1550 nm Forward Transmitter - Performance Product User Manual Technetix Group Limited May/2016 - Version 1.0 sales@technetix.com • technetix.com...
  • Page 3: Table Of Contents

    AIMA3000.FT5P Product User Manual Contents About This Manual ..............................5 Chapter Overview ....................................5 Related Documentation ..................................5 Document Conventions ..................................6 Technical Support ....................................6 Precautions .................................7 Overview ..................................8 Product Description ....................................8 3.2 Product Key Features ....................................9 3.3 Specifications ......................................10 3.4 Block Diagram ......................................12 3.5 Order Details ......................................13...
  • Page 4 AIMA3000.FT5P Product User Manual Module Configuration & Alarm setup ........................31 Port Configuration screen ..................................31 6.1.1 Confirming Input Signal ................................34 6.1.2 Alarm Status Pages ..................................35 6.1.3 Module operating voltage and temperature alarm ......................36 6.1.4 Module Port Alarms..................................37 6.1.5 Alarm Monitoring Configuration ..............................38 6.1.6 Input / Output Status Monitoring ...............................40...
  • Page 5: About This Manual

    The following documents may be used in conjunction with this manual: • Technetix.AIMA3000 - Product User Manual • Technetix.AIMA ASMM - Product User Manual • AIMA3000 NMS Web Management System Product User Manual Technetix.NMS3-EPSM - Basic Inventory Management Technetix.NMS3-EPSM - Basic Alarm Management Technetix.NMS3-EPSM - Basic System Management...
  • Page 6: Document Conventions

    ‘*’ Asterisk: Points marked with an asterisk means there is a corresponding note on the page 1.4 Technical Support If you need help in the process of setting up and maintaining an FT5P, please contact Technetix’s technical support staff: Europe:...
  • Page 7: Precautions

    Outage or overload requiring service and repairs Unplug the unit and refer the servicing to Technetix qualified service personnel only. Servicing and repairs DO NOT attempt to service this unit yourself. Refer all servicing needs to Technetix qualified service personnel only. WARNING! Exposure to class 3A laser radiation is possible.
  • Page 8: Overview

    3 Overview 3.1 Product Description The 1550 nm Forward Transmitter - Performance (FT5P) is designed to plug into Technetix latest Advanced Intelligent Multi- services Access platform (AIMA3000). This series of modules includes Monolithic Distributed Bragg Reflector (DBR) laser with a Silicon Optical Amplifier and an Indium- Phosphide (InP) Mach-Zehnder Modulator provide AIMA with a cost-effective system for 1550 nm transmissions for DWDM applications when used for optical ITU frequency grids.
  • Page 9: Product Key Features

    • Remote firmware upgrade and auto upload/download of configuration files through ASMM web interface or using Technetix NMSE • Bulk firmware updates through Technetix NMSE • FCC, CE and RCM (1) compliant See Declaration of Conformity for current status. Technetix Group Limited May/2016 - Version 1.0...
  • Page 10: Specifications

    -40 ~ +70 °C Storage humidity 90 % (Non-condensing) Dimensions (W*D*H) 24.6 * 410 * 152.5 mm Weight 0.88 kg Supported network Technetix NMSE or through ASMM’s Web Interface management options Technetix Group Limited May/2016 - Version 1.0 sales@technetix.com • technetix.com...
  • Page 11 AIMA3000.FT5P Product User Manual Notes: (1) The factory default ITU optical channel is 33. (2) dBuV=60+dBmV (3) One mini-SMB connectors on front panel to measure RF input before the laser transmitter. (4) MER and BER are tested with 117 QAM256 (301.25 MHz~997.25MHz). All are measured thought EDFA, launch power of +20 dBm, 20 km of fibre.
  • Page 12: Block Diagram

    AIMA3000.FT5P Product User Manual 3.4 Block Diagram Figure 3-1 Block diagram FT5P Table 3-1 FT5P Block Diagram Glossary Parameters Glossary Narrowcast Broadcast ATTEN Attenuator -20 dB OMI TP -20 dB Test Point TO BACK PLANE AND COMMS Data Bus Central Processing Unit Technetix Group Limited May/2016 - Version 1.0...
  • Page 13: Order Details

    AIMA3000.FT5P Product User Manual 3.5 Order Details A-FT5P-[U]-[V]-[W]-[X]-[Y]-[Z] 1550 nm Forward Transmitter – Performance Options: Optical Ports Single (1) Dual (2) Optical Output Power per Port 5 dBm (3 mw) 6 dBm (4 mw) 7 dBm (5 mw) 8 dBm (6.3 mw)
  • Page 14 (1) Default 5 dBm, contact Technetix Representatives for order detailed 6~15 dBm output power. (2) Default spacing is 100 GHz. For other wavelength configurations not listed, please contact Technetix. (3) Standard option. Contact a Technetix Sales Representative for availability of other options.
  • Page 15: Module Characteristics

    AIMA3000.FT5P Product User Manual 4 Module Characteristics 4.1 Module Appearance and Port Layout 4.1.1 Overview Front Panel Rear Panel Figure 4-1 Module Appearance Technetix Group Limited May/2016 - Version 1.0 sales@technetix.com • technetix.com...
  • Page 16: Front Panel Layout

    AIMA3000.FT5P Product User Manual 4.1.2 Front Panel Layout Figure 4-2 FT5P Front Panel Layout Technetix Group Limited May/2016 - Version 1.0 sales@technetix.com • technetix.com...
  • Page 17 AIMA3000.FT5P Product User Manual Table 4.1 RT5S Front Panel Functions Item Number Item Description Module Gain Control Mode Indicator MODE LED MGC: Green Light Blinking AGC: Green Module Alarm Indicator Normal: Green STATUS LED Minor Alarm: Amber Major Alarm: Red...
  • Page 18: Rear Panel Layout

    AIMA3000.FT5P Product User Manual 4.1.3 Rear Panel Layout Figure 4-3 Rear Panel Layout Technetix Group Limited May/2016 - Version 1.0 sales@technetix.com • technetix.com...
  • Page 19 AIMA3000.FT5P Product User Manual Table 4-2 FT5P Rear Panel Functions Serial Number Item Description NC1 IN Narrowcast RF input BC1 IN Broadcast RF input NC2 IN Narrowcast RF input BC2 IN Broadcast RF input Air Vent Air vent allowing air to flow out of the module...
  • Page 20: Installation

    Before installing this device, you must ensure that the unit is intact and ready for installation. Unpack and check the unit: Open the box to check for any damage that may have occurred during shipment. If damage is found, please contact a Technetix customer support representative. Necessary equipment and tools for installation: Table 5.1 Necessary equipment and tools for installation...
  • Page 21: Module Installation

    AIMA3000.FT5P Product User Manual 5.3 Module Installation Gently depress the orange retaining clip and release the hinged tab Hinged tab AIMA Module Orange retaining clip Hold the AIMA module casing upright, align it with the AIMA3000 slide rails for the correct slot, and insert the module until it reaches the multi-pin connector.
  • Page 22: Connecting Optical Cables

    AIMA3000.FT5P Product User Manual After the module is inserted, gently push the hinged tab until it snaps into the orange retaining clip. While pushing down on the hinged tab, the AIMA module will mate with the power bus and will lock in into the chassis...
  • Page 23 AIMA3000.FT5P Product User Manual Then, pull the panel forward. Then lift up the handle and slide the fibre guide out of the front of the chassis. Technetix Group Limited May/2016 - Version 1.0 sales@technetix.com • technetix.com...
  • Page 24: Using The Fibre Tray

    AIMA3000.FT5P Product User Manual DO NOT remove the dust cap from the fibre connector until right before connecting it to the input port. Raise the clip, insert the fibre connector, and then lower the clip over the connector. When using the sliding guide, put the fibre connector in the clip and slide it in from the rear to the front, through the chassis.
  • Page 25 AIMA3000.FT5P Product User Manual Use the Fibre Guide Tool to organise the cables and wires in the fibre tray to prevent tangles and the blocking of the guide rails. Fibre Tray Area Cut-outs Technetix Group Limited May/2016 - Version 1.0 sales@technetix.com...
  • Page 26: Cleaning The Fibre Connector Ends And Front-Panel Optical Ports

    AIMA3000.FT5P Product User Manual 5.4.3 Cleaning the Fibre Connector Ends and Front-panel Optical Ports To obtain a good quality optical input signal, optical fibre input ports and fibre connector ends must be carefully cleaned. Connection terminal Head face Figure 5-4 When cleaning the optical fibre-connector end, remove the dust cap and then use a lint-free cloth dampened with a static dissipative solvent to clean the angled surface.
  • Page 27: Connecting The Optical Fibres

    AIMA3000.FT5P Product User Manual 5.4.4 Connecting the Optical Fibres Carefully lift up the hinged cover of the optical input port, align the raised tab on the connector with the slot in the port. Insert the connector until the connector is securely held in place indicated by a clicking sound.
  • Page 28: Test The Optical Output Signal

    AIMA3000.FT5P Product User Manual 5.6 Test the RF Input Signal After the input signal has been confirmed, the optical power of the associated optical output port should be tested. Use the optical power meter to test the output levels; the output values should be in accordance with the technical specifications.
  • Page 29 AIMA3000.FT5P Product User Manual FT5P Initial Setup Pending finalisation of module. Before installing the FT5P, check the optical output ferrule tip with a fibrescope to ensure that the connector is clean (pictured below). The cap on the optical output connector does not prevent contamination from getting on to the optical connector, it prevents the laser from being emitted when laser is on and no optical patch cord is installed.
  • Page 30 AIMA3000.FT5P Product User Manual Confirm that the "Alarm Control" is enabled. Check the required selection and click on “Submit” to enable/disable alarms. Technetix Group Limited May/2016 - Version 1.0 sales@technetix.com • technetix.com...
  • Page 31: Module Configuration & Alarm Setup

    6 Module Configuration & Alarm setup The module configuration settings can be configured using the web interface and Technetix NMSE (network management software). This manual only provides details on the web interface. For login details and network setup, please refer to the AIMA-ASMM user manual.
  • Page 32 AIMA3000.FT5P Product User Manual Figure 6.2 In the RF configuration screen “Laser Output Control”, “Modulation Mode”, “Input AGC Mode”, “Wavelength Set”, “Broadcast MGC”, “Norrowcast MGC”, “OMI Offset”, “SBS Control”, and “Alarm Settings” become available. For proper RF settings with different RF channel loads, see the example calculations shown in 6.1.1. All transmitters have independent settings and they need to be adjusted separately.
  • Page 33 AIMA3000.FT5P Product User Manual Table 6 1 Port Configuration Parameters Description Description Items Sub Items Effect and Configuration Method Slot Port Information Module Type Port Laser Type Laser Wave Length Laser Output Status ON / OFF Laser TEC (thermoelectric) Current...
  • Page 34: Confirming Input Signal

    AIMA3000.FT5P Product User Manual 6.1.1 Confirming Input Signal Input Signal is shown as the red box in Figure 6-3: Figure 6-3 Input Power Calculations The relationship between input power and the number of channels: Per channel Power = Input Power -10*LOG (number of channels) On Figure 6-3, the interface displays the “Broadcast Input Power”/“Narrowcast Input Power”...
  • Page 35: Alarm Status

    AIMA3000.FT5P Product User Manual 6.1.2 Alarm Status Pages Click the Alarms tab on the menu bar to display an overview of the alarm status of all the installed modules as shown in Figure 6-4 below. The each module row has an alarm status indicator used to show: •...
  • Page 36: Module Operating Voltage And Temperature Alarm

    AIMA3000.FT5P Product User Manual 6.1.3 Module operating voltage and temperature alarm Click on the corresponding module, as shown in the following figure, to view the module alarm information. By clicking on “FT5P”, under “Modules” tab, the operator can view the module temperature and power supply voltage alarms. The operator can utilise the status indicators to judge whether the module is working properly.
  • Page 37: Module Port Alarms

    AIMA3000.FT5P Product User Manual 6.1.4 Module Port Alarms Click on one of the Port Tabs under the module on the left column, as shown in Figure 6-6. On the module port page, the operator can view the BC Input Power, NC Input Power, Laser Case Temperature, Laser Output Power, Laser Output, and...
  • Page 38: Alarm Monitoring Configuration

    AIMA3000.FT5P Product User Manual 6.1.5 Alarm Monitoring Configuration Monitoring Function ON / OFF In Configuration section on Modules page, click Alarm Control to Enable/Disable Monitoring Function. Temperature, +12V, +5V, -5V Voltage Alarm Levels Management By default, temperature, +12 V, +5 V, - 5V voltage alarms are all set to ON. The check box ☑ as shown in Figure 6-7 controls the detection is set to ON or OFF.
  • Page 39 AIMA3000.FT5P Product User Manual Table 6-2 Modules Page Alarms Threshold Parameters Instruction Threshold Dead Default Alarm Parameter Units HIHI Normal LOLO changeable by Band Enable user Temperature +12V Input voltage 13.5 10.5 +5V Input voltage -5V Input voltage -4.4 Technetix Group Limited May/2016 - Version 1.0...
  • Page 40: Input / Output Status Monitoring

    AIMA3000.FT5P Product User Manual 6.1.6 Input / Output Status Monitoring To setup Input / Output status monitoring, select one of the Port Tabs from the left menu, and then the monitoring parameters will be listed for the designated transmitter under the “Alarm Settings” section, click on ☑ to toggle the alarms.
  • Page 41 AIMA3000.FT5P Product User Manual Table 6-4 Module Alarm Indicator Definitions Parameters (Common) Description Definitions Related Indicators Lighting Conditions Power OFF Power OFF Power OFF All OFF During Module Initiating AM Power ON Green (2 times / sec) Power ON No Alarm...
  • Page 42 AIMA3000.FT5P Product User Manual STAT “Laser Output Status LSR1/ Laser-Output-Major-ALM Alarm ”is set to “enable Laser-Shutdown LSR2/ Major” LSR3/ LSR4 STAT “Laser Output Status LSR1/ Laser-Output-Minor-ALM Alarm” is set to “enable Laser-Shutdown LSR2/ Amber Minor” LSR3/ LSR4 Table 6-5 Module Alarm Indicator Definitions...
  • Page 43: Logs Management

    AIMA3000.FT5P Product User Manual 6.2 Logs Management The operator can view all the alarms of the modules in the chassis on the Logs Management page. Click “Logs” to enter the Logs Management page. Refer to Figure 6-9 below: Figure 6-9 Technetix Group Limited May/2016 - Version 1.0...
  • Page 44: Device Upgrade

    * The Web GUI above only supports the manual operation from a local PC. * The FT5P supports automated firmware updates and automatic backup & restore features via TFTP when managed via Technetix NMSE management software. Please refer to the NMSE Product User Manual for more information.
  • Page 45: Restoring Factory Defaults

    AIMA3000.FT5P Product User Manual 6.4 Restoring Factory Defaults Loading factory default can restore the device to the factory default setting. Detailed operations: Click "Modules" tab and click the module to be configured as the page shown in Figure 6-11. Click "Apply" button in Factory Default section.
  • Page 46 AIMA3000.FT5P Product User Manual Table 6-6 Factory default and upgrade configuration parameters table Parameters Conditions Factory Default Value After Software Upgrade Alarm Control Enable/Disable Enable Retained Tx Unit Control ON / OFF Retained Laser Output Control ON / OFF Retained...
  • Page 47: Reboot

    AIMA3000.FT5P Product User Manual 6.5 Reboot The module can be made to reboot remotely. Detailed operations: Click Modules tab, click the corresponding FT5X module, and click the "Apply" button in Reboot section. Next, click on "Submit" to confirm, and then the module will automatically restart. The configuration of the module will not be lost after rebooting.
  • Page 48: Troubleshooting

    AIMA3000.FT5P Product User Manual 7 Troubleshooting Indicator for determining faults If there is a fault, the operator can use the status LEDs to determine the location and condition of the fault. Please see Table 7-1 below: Table 7-1 Fault Judgment Table...
  • Page 49 AIMA3000.FT5P Product User Manual Check the Fans, or lower the room Operating environment Temperature is lower temperature. If the temperature is normal, or higher. please contact Technetix technical support. +12V /+5V /-5VInput Voltage is lower or higher. Please contact Technetix technical support.
  • Page 50: Declaration Of Conformity

    8 Declaration of Conformity According to ISO/IEC Guide 22 and EN45014 Manufacturer's Name: Technetix Manufacturer’s Address: Technetix Ltd, Innovation House, Technetix Business Park, Albourne, West Sussex, BN6 9EB Product Name: FT5P – 1550 nm Forward Transmitter - Performance Conforms to the following standards:...