geminox QAA 73.110 Technical Instructions page 38

Table of Contents

Advertisement

Available languages

Available languages

Level Line
Display
Controller times : All non-safety-related time parameters
544 ZqNach
Overrun time of pumps, max. 210 min
C
ZBreMinP
Minimum burner pause time (heat demand-
C
545
dependent switching hysteresis)
Z_Bw-
Time for instantaneous DHW Comfort function
Comfort2
after consumption (when there is demand for
C
603
heat)
Z_PumpeAus
Duration of pump shutdown when diverting
O
637
Uv
valve changes from space heating to DHW
heating
Z_PumpeVerz
Delay of pump shutdown when diverting valve
O
638
Uv
changes from space heating to DHW heating
Controller coefficients : Setting the controller's dynamics
Proportional coefficient of DHW controller :
C
566 KpBw
KpHz1
Proportional coefficient of heating circuit
O
569
controller
Burner control fan : Burner control parameters in connection with the fan
LmodZL_QAA Setting value QAA73: modulation air at
O
608
ignition load
LmodTL_QAA Setting value QAA73: modulation air at low-
fire; lower limit modulating range
C
609
646 LmodNull
Modulation air when burner control is not
C
operating
Maintenance alarms
BetrStdWart-
Set limit for the number of operating hours
C
625
Grenz
(interval) since last service visit.
InbetrSetzWart
Set limit for the number of startups (interval)
C
626
-Grenz
since last service visit.
627 MonatWart-
Set limit for the number of months (interval)
C
Grenz
since last service visit.
GeblaeseWart
Set limit of fan speed for service visit.
C
628
Grenz
Wartungs-
Enduser can acknowledge a pending
UF
629
Quittierung
maintenance alarm via this parameter.
630 Wartungs-
Setting flags of maintenance alarms.
C
Einstellungen
WartRepDauer Selected period of time for repetition of
C
633
maintenance alarm after acknowledgement
BetrStdWart
Operating hours (interval) since last service
C
634
visit
C
635 InbetrSetzWart Startups (interval) since last service visit.
MonatWart
Months (interval) since last service visit
C
636
718 BetrStd
Hours run burner
C
C
719 BetrStdHz
Hours run heating mode
720 BetrStdBw
Hours run DHW heating
C
721 BetrStZone
Hours run zone
C
722 InBetrSetz
Start counter
C
Wartungscode Maintenance code contains enumeration
UF
726
value of maintenance alarm (precise cause)
727 Diagnosecode Internal Diagnostic code b0
UF
Function
(0 = deactivated ; 255 = 4h15min)
Type 5-25
SEP/10-35 SEP
Type C/M40/M75/B120
Type 5-25 S/SEP
Type 10-35 SEP/ 10-50 SEP
Type 2-13
Type 2-17
- 18 -
Factory setting : boiler version
Range
0.9-9
2-13/2-17
0...255
10 min
10 min
min
0...3600 s 0 s
0 s
0...255
min
10 min
10 min
-
-
0 ... 10 s 0
0
0 ... 10 s 0
0
0...
15,9375
0.75
0.75
-
-
-
-
0...
0.06
0.06
15,9375
0...100 % 28%
28%
0...100 % 10%
-
11%
-
10 %
0...100 % 0
0
0...9998
0
0
hrs
0...9995
0
0
0...255
0
0
months
0...9950
0
0
1/min
0...1
0
0
0...255
0
0
0...255
0
0
days
0...10000
0
0
hrs
0...10000 0
0
0...255
0
0
months
h
0
0
h
0
0
h
0
0
0
0
h
-
0
0
0...255
0
0
-
-
PARAMETER LIST
5-25
10-50
10 min
10 min
0 s
0 s
10 min
10 min
5 min
5 min
0
0
0
0
0.75
0.06
1
-
-
1
0.06
0.06
28%
22%
12.5%
13.5%
-
-
-
-
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-
-