Advertisement

TM
TBEN-LG EtherNet/IP
Configuration Guide
Date: 03.20.2015
Version: 1.4
TURCK Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TBEN-LG EtherNet/IP and is the answer not in the manual?

Questions and answers

Summary of Contents for turck TBEN-LG EtherNet/IP

  • Page 1 TBEN-LG EtherNet/IP Configuration Guide Date: 03.20.2015 Version: 1.4 TURCK Inc.
  • Page 2 TBEN-LG EtherNet/IP Configuration Guide TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 3: Table Of Contents

    Install EDS File(s) ......................31 Create new TBEN Module ....................33 Configure Connection and data format ................36 Module Definition Data Format ..................37 TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 4 Home Page ........................50 Login / password ......................51 Network Configuration .....................52 Station Configuration .......................53 Station Diagnostics ......................54 Ethernet Statistics ......................54 IO Parameters .........................55 TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 5: Introduction

    It also shows how to set up device IP address using different tools. TBEN-LG devices can be configured with EDS files, or using a generic device profile. Device web server provides advanced configuration and diagnostics information. TURCK IP address tool is used for quick discovery of TURCK devices residing on different VLANS.
  • Page 6 TBEN-LG EtherNet/IP Configuration Guide TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 7: Tben-Lg

    Inputs protected per connector; outputs are individually protected Device Level Ring Quick Connect; QC time 100msec Address Conflict Detection and resolution TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 8: Connection Diagrams

    3 = RD- 4 = First input 4 = RD- 4 = TD- 5 = FE (see „Note 2“) (see „Note 1“) TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 9 3 = V2 (-) 4 = RD- 4 = TD- 4 = First output 5 = FE (see „Note 1“) TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 10 VAUX1 = V1 – 0.2 VDC (voltage drop over protective circuit) VAUX2 = V2 – 0.2 VDC (voltage drop over protective circuit) TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 11: Led Diagnostics

    (C0, C1, …, C7) − signal pin number of the appropriate connector ( 2, 4) − LD24: connector 2, pin 4 TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 12: Ethernet Ports And Device Fault Leds

    Normal operation ( red / green ) red on Diagnostics active red on / green on Not valid state TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 13: Power Led

    V1 and V2 power on ( green ) V1 power on flashing V2 power off or undervoltage < 18V TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 14: Io Leds Tben-Lg-16Dip

    Output active LD04,…,LD74 Power overload at the corresponding output chan- ( red / green ) red on nel CHxy TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 15: Io Leds Tben-Lg-8Dip-8Dop

    Output channel CH22 active (solid green / flashing green on / flashing red red). e.g. LD22 Power overload at the input channel CH24 (flashing red) TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 16: Io Data Format

    Err Out0…15: Short circuit output 0…15 Inv.I0…I15: Inverted input signal 0…15 TBEN-LG-16DIP Note: a blank field means reserved or not used. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 17: Tben-Lg-8Dip-8Dop

    TBEN-LG EtherNet/IP Configuration Guide TBEN-LG-8DIP-8DOP TBEN-LG-16DOP TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 18: Tben-Lg-16Dxp

    TBEN-LG EtherNet/IP Configuration Guide TBEN-LG-16DXP TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 19: Setting Up Ip Address

    Setting rotary switches to any other position not listed on the device or data sheet sets device into DHCP mode and bus LED flashes green / red. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 20: Bootp/Dhcp Mode (300/400)

    When the device is set to 500 (PGM) mode, its IP address can be further changed using either the IP Address Tool or WEB page. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 21: Pgm-Dhcp Mode (600)

    When the device is set to 600 (PGM-DHCP) mode, its IP address can be further changed using either the IP Address Tool or WEB page. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 22: Pgm Mode (500, 600)

    If IP address is unknown, read the “Factory Reset Mode (900)” to reset device to factory default setup. IP address − When device web server starts, enter “password” into “Password” field and click “Login” TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 23 Enter new IP address, Netmask and Default Gateway and press “Submit” − To reboot device, leave rotary switches at 500 and cycle device power TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 24: Ip Address Tool

    Modify IP address when rotary switches are set to 500 / PGM mode − Access device web page, when tool and device are on the same subnet TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 25: Pgm (500) And Ip Address Tool

    PGM (500) and IP address tool Start the IP address tool and click “Search”: Highlight device which is in PGM mode and click “Change”: TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 26 TBEN-LG EtherNet/IP Configuration Guide Enter new IP address and click “Write to device”: Search again and verify setup: TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 27: Restore Mode (0)

    Power up the device (the BUS LED solid red) and wait 10 sec − Set the rotary switches to 600 (PGM-DHCP mode) − Cycle power to the device TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 28: Tben Ethernet/Ip Configuration

    TBEN Connection Configuration • Module Definition Data Format • Communication RPI, Multicast / Unicast • TBEN Input, Output and Configuration Data Tags TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 29: Configure Ethernet/Ip User Interface

    Add new EtherNet/IP driver that is used to establish connection between programing PC and the Logix controller: Select designated driver and click apply: TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 30: Create Rslogix5000 Project

    TBEN-LG EtherNet/IP Configuration Guide Create RSLogix5000 Project Open new RSlogix5000 project and configure PLC resourced or open an existing project. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 31: Install Eds File(S)

    TBEN-LG EtherNet/IP Configuration Guide Install EDS File(s) Tools > EDS Hardware Installation Tool Follow the wizard instructions TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 32 TBEN-LG EtherNet/IP Configuration Guide Register single file or directory of EDS files and follow registration dialog: TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 33: Create New Tben Module

    Configure new TBEN device in RSLogix5000:  File > New Component > Module Or right-click at “Ethernet” and select “New module” TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 34 “Select Module Type” page provides a search box: Enter device name into search box Highlight device to be configured Click “Create” TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 35 Enter required data into the “New Module” General page: − Name (tag name) − IP address − Click “Change” to open Module Definition page TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 36: Configure Connection And Data Format

    When Module Definition page is opened select: Connection type = Exclusive Owner Data size format = INT Click OK and follow dialog to complete device configuration. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 37: Module Definition Data Format

    The Input-Only and Listen-Only connections may be used to configure the device with multiple PLCs. The TBEN device supports up to 3 TCP sessions and 8 CIP connections. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 38: Tben Data Tags

    Input data tag: Device “Connection Faulted” flag is also attached to the input data by the controller. Output data tag: TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 39 Disable auto-recovery of outputs ( requires user to turn-off and then-on an output that was previously faulted) − Stretch input signal for specified time TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 40: Tben-Lg Configuration Parameters

    0 = output driver is not be enabled. Output_Enable Out Enable x 1 = output driver is enabled Default = 1 TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 41: Configuration Assembly Data Structure

    • Quick Connect • INVx Input Inversion • SROx Output Short Recovery • IStx Input pulse stretching • Output enable TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 42 Byte25 ISt11 Byte26 ISt12 Byte27 ISt13 Byte28 ISt14 Byte29 ISt15 Byte30 Reserved Byte 31-45 Table 2.5 – TBEN-LG-16DIP configuration data TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 43 SRO 11 SRO 10 SRO 9 SRO 8 Byte12 Reserved Byte13 Byte 14-45 Reserved Table 2.6 – TBEN-LG-16DOP configuration data TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 44 ISt10 Byte30 ISt11 Byte31 ISt12 Byte32 ISt13 Byte33 ISt14 Byte34 ISt15 Byte 35-45 Reserved Table 2.7 – TBEN-LG-16DXP configuration data TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 45: Tben-Lg Profile Info

    The device property is a subject to change. It provides path to view installed EDS file: right-click on the device and select “Properties”: Click on marked icon and follow instructions: TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 46: Tben Configuration Using Generic Device

    Add Ethernet Generic device (as seen in RSLogix5000 rev 20 and up) − Configure device by entering assembly instances and data size as follows: TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 47: Configure Tben-Lg-16Dip

    TBEN-LG EtherNet/IP Configuration Guide Configure TBEN-LG-16DIP Note: “Comm Format” is always “Data – INT”. Configure TBEN-LG-16DOP TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 48: Configure Tben-Lg-8Dip-8Dop

    TBEN-LG EtherNet/IP Configuration Guide Configure TBEN-LG-8DIP-8DOP Configure TBEN-LG-16DXP TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 49: Configure Connection

    The “Connection” page setup is identical for all TBEN devices as follows: Controller organizer differentiates between EDS and Generic configured device by default icon. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 50: Tben Web Server

    There are several pages such as "Station Diagnostics", "Ethernet Statistics" and "Links" which can be accessed for viewing. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 51: Login / Password

    Enter initial password as “password” and click Login. The administrator privileges allow chang- ing device setup using page links listed to the left. The home page shows the same information: TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 52: Network Configuration

    TBEN-LG EtherNet/IP Configuration Guide Network Configuration The network configuration page is used to modify EtherNet port settings and device IP address. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 53: Station Configuration

    "Reboot" executes a power-cycle at the device. − “Reset to Factory Defaults” corresponds to switch position 900 and it restores factory de- fault setup, including password. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 54: Station Diagnostics

    The diagnostics page provides historical content of diagnostics from the last device power-up. Ethernet Statistics The Ethernet statictics page provide currrent status and statistics of Ethernet ports. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 55: Io Parameters

    Disable automatic recovery of an output upon recovery from a short condition − Pulse stretching value is in range 0-127; input signal is extended in steps of 10msec from 0-1270 msec. TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...
  • Page 56 TBEN-LG EtherNet/IP Configuration Guide TURCK • 3000 Campus Drive • Minneapolis, MN 55441-2656 Phone: 763.553.7300 • Toll Free: 800.544.7769 • Fax: 763.553.0708 • www.turck.us...