HeatStar HSP40E Operating Instructions And Owner's Manual

HeatStar HSP40E Operating Instructions And Owner's Manual

Electric construction heater

Advertisement

Quick Links

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
READ INSTRUCTIONS CAREFULLY:­Read­and­follow­all­instructions.­Place­instructions­in­a­safe­
place­for­future­reference.­Do­not­allow­anyone­who­has­not­read­these­instructions­to­assemble,­
light,­adjust­or­operate­the­heater.
Electric Construction
HEATER
Languages included
•­ English
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
­ — ­ This­heater­has­hot­or­arcing­parts­inside.­Do­not­use­it­in­areas­where­gasoline,­paint­or­other­
flammable­liquids­are­used­or­stored.
—­ Service­must­be­performed­by­a­qualified­service­agency.
OPERATING INSTRUCTIONS
AND OWNER'S MANUAL
HEATSTAR­by­ENERCO,­4560­W.­160TH­ST.,­CLEVELAND,­OHIO­44135­•­866-447-2194
For Indoor Use Only
Not For Use Outdoors
Model­#
HSP40E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HSP40E and is the answer not in the manual?

Questions and answers

Summary of Contents for HeatStar HSP40E

  • Page 1 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! OPERATING INSTRUCTIONS Model­# AND OWNER’S MANUAL HSP40E READ INSTRUCTIONS CAREFULLY:­Read­and­follow­all­instructions.­Place­instructions­in­a­safe­ place­for­future­reference.­Do­not­allow­anyone­who­has­not­read­these­instructions­to­assemble,­ light,­adjust­or­operate­the­heater. Electric Construction HEATER For Indoor Use Only...
  • Page 2: Table Of Contents

    WARNINGS­................. 2 HEATER­SPECIFICATIONS­ ............. 3 PRINCIPAL­OF­OPERATION­............3 SET­UP­AND­OPERATION­INSTRUCTIONS­........4 MAINTENANCE­AND­STORAGE­­ ..........4 HEATER­SIZING­AND­CORD­SELECTION­ ........4 TROUBLESHOOTING..............5 WIRING­DIAGRAMS­ ..............6-7 PARTS­LIST­ ................8-10 WARRANTY­................12 INSTRUCTIONS­FOR­ORDERING­PARTS­ ........12 HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
  • Page 3: Heater­specifications

    Switches Overheat Sensors Handle Contactors Steel Housing COOL WARM Ambient Thermostat Sensor Tube Aluminum Electric Fan Fully Sealed, Non-Glowing Fan Blades Motor Stainless Steel Heating Element Solid Plastic (15 pcs) Wheels HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
  • Page 4: Set­up­and­operation­instructions

    2.­ Connect­heater­to­a­480V,­60­Hz­three­phase,­50­Amp­power­ The HSP40E heater would require a minimum 40,000 Watt source. (40KW), 480 volt three phase generator that can provide 50 IMPORTANT:­ALL­POWER­SOURCES­NEED­TO­BE­EQUIPPED­WITH­A­ amps of continuous power. CIRCUIT­BREAKER! NOTE:­When­power­is­first­applied­to­unit,­the­heater­fan­may­blow­air­ NOTE:­This­heater’s­Heating­Coil­Ohm­Reading­is­85. out­of­heater­INLET.­If­this­condition­occurs,­(after­first­removing­power­ Electrical Cord Selection for from­cord)­reverse­the­first­two­hot­wires­at­heater­terminal­inlet­block.­(3­...
  • Page 5: Troubleshooting

    Motor­starts­but­no­heat •Ambient­Thermostat •Turn­thermostat­above­ambient­ •Replace temperature •Overheat­limit(s) •Check­for­continuity.­It­is­a­closed­switch •Replace •Contactors •Make­sure­they­are­clean,­tight,­and­ •Replace that­they­pull­in­when­voltage­is­applied •Heating­Elements •Visual­check­for­burns.­Check­resistance­ •85K­Ohms of­each­individual­element Heater­operates,­fan­doesn’t­cool­ •Fan­Cooldown­Thermostat •Check­for­resistance •Replace the­unit­after­thermostat­is­satisfied •Check­for­proper­wiring •Rewire High­limit­tripping •Low­Volume­of­Air •Duct­restrictions •Straighten­duct •Dust­buildup­on­inlet­grill •Clean­fan­area HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
  • Page 6: Wiring­diagrams

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! WIRING DIAGRAM HSP40E 480 Volt 60 Hz 3 PH DESCRIPTION DESCRIPTION 41 158 Transformer 41 154 Toggle­Switch­(for­output­+­16KW) 41 156...
  • Page 7 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! WIRING DIAGRAM HSP40E WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.
  • Page 8: Parts­list

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! HSP40E HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
  • Page 9 WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY. HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
  • Page 10 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CONTROL BOX HSP40E DESCRIPTION DESCRIPTION 41 161 Ambient­Thermostat 41 158 Transformer­(PETR) 41 151 Contactor,­3-Pole­(S/N­prior­to­2142­use­41 152) 41 156 Fuse 2A 41 152 Contactor,­4-Pole...
  • Page 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NOTES: HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
  • Page 12: Warranty

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Model­# OPERATING INSTRUCTIONS AND OWNER’S MANUAL HSP40E WARNING: USE­ONLY­MANUFACTURER’S­REPLACEMENT­PARTS.­USE­OF­ANY­OTHER­PARTS­ COULD­CAUSE­INJURY­OR­DEATH.­REPLACEMENT­PARTS­ARE­ONLY­AVAILABLE­ DIRECT­FROM­THE­FACTORY­AND­MUST­BE­INSTALLED­BY­A­QUALIFIED­SERVICE­ AGENCY.­ PARTS ORDERING INFORMATION: PURCHASING: Accessories­may­be­purchased­at­any­HEATSTAR­by­ENERCO­local­ dealer­or­direct­from­the­factory­ FOR INFORMATION REGARDING SERVICE Please­call­Toll-Free­866-447-2194...

Table of Contents