Page 1
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! OPERATING INSTRUCTIONS Model# AND OWNER’S MANUAL HSP40E READ INSTRUCTIONS CAREFULLY:Readandfollowallinstructions.Placeinstructionsinasafe placeforfuturereference.Donotallowanyonewhohasnotreadtheseinstructionstoassemble, light,adjustoroperatetheheater. Electric Construction HEATER For Indoor Use Only...
Switches Overheat Sensors Handle Contactors Steel Housing COOL WARM Ambient Thermostat Sensor Tube Aluminum Electric Fan Fully Sealed, Non-Glowing Fan Blades Motor Stainless Steel Heating Element Solid Plastic (15 pcs) Wheels HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
2. Connectheatertoa480V,60Hzthreephase,50Amppower The HSP40E heater would require a minimum 40,000 Watt source. (40KW), 480 volt three phase generator that can provide 50 IMPORTANT:ALLPOWERSOURCESNEEDTOBEEQUIPPEDWITHA amps of continuous power. CIRCUITBREAKER! NOTE:Whenpowerisfirstappliedtounit,theheaterfanmayblowair NOTE:Thisheater’sHeatingCoilOhmReadingis85. outofheaterINLET.Ifthisconditionoccurs,(afterfirstremovingpower Electrical Cord Selection for fromcord)reversethefirsttwohotwiresatheaterterminalinletblock.(3...
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! WIRING DIAGRAM HSP40E 480 Volt 60 Hz 3 PH DESCRIPTION DESCRIPTION 41 158 Transformer 41 154 ToggleSwitch(foroutput+16KW) 41 156...
Page 7
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! WIRING DIAGRAM HSP40E WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! HSP40E HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
Page 9
WARNING: USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY. HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
Page 10
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CONTROL BOX HSP40E DESCRIPTION DESCRIPTION 41 161 AmbientThermostat 41 158 Transformer(PETR) 41 151 Contactor,3-Pole(S/Npriorto2142use41 152) 41 156 Fuse 2A 41 152 Contactor,4-Pole...
Page 11
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NOTES: HEATSTAR Electric Construction Heater Operating Instructions and Owner’s Manual...
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Model# OPERATING INSTRUCTIONS AND OWNER’S MANUAL HSP40E WARNING: USEONLYMANUFACTURER’SREPLACEMENTPARTS.USEOFANYOTHERPARTS COULDCAUSEINJURYORDEATH.REPLACEMENTPARTSAREONLYAVAILABLE DIRECTFROMTHEFACTORYANDMUSTBEINSTALLEDBYAQUALIFIEDSERVICE AGENCY. PARTS ORDERING INFORMATION: PURCHASING: AccessoriesmaybepurchasedatanyHEATSTARbyENERCOlocal dealerordirectfromthefactory FOR INFORMATION REGARDING SERVICE PleasecallToll-Free866-447-2194...
Need help?
Do you have a question about the HSP40E and is the answer not in the manual?
Questions and answers