LEDs
Red
Off
Server rear panel - model 4040
The rear panel of the server features numerous ports, connectors, switches, and LEDs.
Figure 14 Server rear panel components for model HNAS 4040
Note: Except for the ports and connectors described in the following, none of
the other ports or connectors should be used without guidance from
technical support.
Item
1
Clustering ports 10 GbE
Hitachi NAS Platform and Hitachi Unified Storage Series 4000 Hardware Reference
Table 9 Fan status LEDs
Fan has failed, fan speed is out of acceptable range, or fan speed is
not being reported. (This LED will be on if the corresponding fan has
been removed.)
When on, this LED indicates a failure and that the fan is not operating
correctly. Replace the fan as soon as possible.
Normal operation.
Connectivity
Chapter 4: Hitachi NAS Platform server components
Server rear panel - model 4040
Meaning
Quantit
y
2
For cluster management and
heartbeat, connect to:
Two way configuration: Connect to
■
corresponding cluster server ports
(left port to left port and right port
to right port).
N-way configuration: Connect to 10
■
GbE switch.
Description
43