1. All wiring must be in accordance with all applicable National (NEC/CEC), state, and local codes
2. To avoid overheating and possible damage to other equipment, DO NOT use to control receptacles, fluorescent lighting
fixtures, or transformer-supplied appliances
3. Controls require separate wires in the wall-box for fan and light
4. When no "ground means" exists within the wall-box, then NEC 404.9 exception to (b) allows a control without a ground
connection, to be installed as a replacement. For this type of installation, cap or remove the green control ground wire.
A control installed under this exception (NEC 404.9 exception to (b) must be provided with a plastic, noncombustible,
UL listed wallplate
•• (b) refers to units which have been subject to unauthorized repair, opened, taken apart or otherwise modified
CAUTION
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES.
Electrical products can cause death or injury, or damage to property.
If in any doubt about the installation or use of this product, consult a competent electrician.

INSTALLATION GUIDE

1. Turning power OFF

Warning — Risk of SHOCK, FIRE or DEATH, turn power OFF at circuit breaker or remove fuse, and make sure
the power is disconnected.
2. .Single-pole wiring the fan speed control
info@ortechindustries.com
www.ortechindustries.com

WARNING

WARNING — THE INSTALLATION MUST BE CARRIED OUT BY
A QUALIFIED ELECTRICIAN.
1. Turn off circuit breaker prior to installing the fan speed control
2. Speed Controllers can only be installed by a qualified electrician
3. Before installation or maintenance, please read through this instruction manual
4. Use copper wires only

Application Notice

13376 Comber Way
Surrey BC V3W 5V9
375 Admiral Blvd
Mississauga
,
ON L5T 2N1
Instruction Manual
1-888-543-6473
1-888-541-6474

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OD-SCV-10A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ortech OD-SCV-10A

  • Page 1 Speed Controllers Instruction Manual MODEL OD-SCV-10A WARNING WARNING — THE INSTALLATION MUST BE CARRIED OUT BY A QUALIFIED ELECTRICIAN. 1. Turn off circuit breaker prior to installing the fan speed control 2. Speed Controllers can only be installed by a qualified electrician 3.
  • Page 2 Speed Controllers Instruction Manual MODEL OD-SCV-10A INSTALLATION GUIDE 3. Test fan speed control prior mounting in the wall-box 1. Restore power at the circuit breaker or fuse 2. As shown on the following, turn the rotary knob slowly from left to right to control fan ON/OFF and speed 3.

Table of Contents