Page 1
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera User Manual 2020-01...
Page 2
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Thank you for purchasing our Dual Sensor Infrared Body Temperature Screening Thermal Camera. Please read this manual carefully before using. This camera’s technical specifications, operational methods and precautions are all included in this manual.
Page 3
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Dangers 1.Please read this manual carefully before installation. 2. Please note the warning notices on the camera and in this manual. 3. Please apply exactly the power supply and voltage listed in this manual.
Dual Sensor Infrared Body Temperature Screening Thermal Camera hapter 1 Camera Introduction 1. Overview G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera, It is a non-contact, large-area, accurate, and efficient temperature measurement and screening device specially designed for dense crowds in public places. Based on the...
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera 2. Appearance Visible lens Thermal camera Chart 1-1 Front and side view Cable connection Chart 1-2 Lateral and side view Page 6 of 34...
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera 4. Connector Camera output line definitions: Pin No. 12V+ Orange Orange Green Green Black white TX+ white RX+ definition (RJ45-1) (RJ45-2) (RJ45-3) (RJ45-6) Pin No. Blue Blue white Brown Brown definition...
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Chapter 2 Operation 1. Installation and cable connection (1) Installation There are various mounting holes on the bottom of the camera, as shown in Chart 1-5. It can be set up quickly with ordinary photography tripod, as shown below.
Page 11
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (2) Aviation Plug Installation Chart 2-2 Aviation Plug Hole Chart 2-3 Aviation plug Pin When installing, please insert the head hole into the socket, make sure that the pin is inserted into the socket, then twist the upper fixed ring upward and to the right, and then complete the docking after hearing "Click"...
Page 12
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (3) Cable connection Power supply Camera connection Network cable Dual Sensor Infrared Body Temperature Screening Computer Thermal Camera Chart 2-5 connection diagram Page 12 of 34...
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera 2. Recommended installation environment The temperature measurement principle of the infrared camera is measured by collecting infrared radiation radiated from the surface of the body of the person. The environmental conditions related to infrared transmission will affect the temperature...
Page 14
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera The erection height is about 1.8-2 meters, the working distance is generally 2-5 meters, and the best temperature measurement distance is about 2-3 meters. Chart 2-7 Camera installation and display Page 14 of 34...
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera 3. Common Faults The table below includes the common faults during operation. Whenever these problems occur, you may refer to this table or contact us directly for proper solution. Fault Possible Cause...
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Chapter 3 Blackbody use and installation instructions 1. Product appearance Note: Please refer to the real object for the appearance of the blackbody. This picture is for reference only. 2. Instructions (1) Connect the power supply, the power supply is AC220V.
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (4) Temperature setting: In this interface, ◀ press . ▲. ▼ key to adjust the value in the (SV) window, set the required temperature, and after the adjustment, wait for the number to no longer change, and the temperature can be used for measurement after 30 minutes.
Page 18
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera In order to ensure the accuracy of temperature measurement, please place the surface temperature calibrator in a stable temperature environment. The ideal environment temperature is 10 ℃ ~ 25 ℃. The inspection must start from the low temperature point and then to the high temperature point.
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera 4. Installation instructions (1) Installation height of thermal imaging temperature measuring camera: 2 meters; installation height of black body: 1.8 meters. The product installation is shown as follows: Thermal camera tripod installation diagram...
Page 20
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (2) The thermal imaging camera and the black body are installed on the same side, the pedestrian path is on the other side, and the distance between the camera and the black body is 3 meters, to avoid obstruction between the camera and the black body during temperature measurement.
Page 21
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (3) The radiating surface of the black body must be facing the camera's irradiation direction, and the black body must be on the left or right of the thermal imaging screen.
Page 22
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (6) The installation area needs to be relatively isolated and stable from the outside world. Avoid outdoor or outdoor communication scenarios. It is not suitable for environments with airflow or strong electromagnetic interference or vibration.
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Chapter 4 Camera debugging instructions The configuration of temperature measurement monitoring is configured after logging in to the thermal imager through the web. Note: 1) It is recommended to use IE browser for web login. For non-IE browsers, please use the compatibility mode to log in.
Page 24
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (2) Temperature detection parameter Switch Settings-Alarm Settings-Intelligent analysis-Body temperature detection-Temperature detection parameter. Our temperature camera is calibrated when it leaves the factory, but the accuracy of the device's temperature measurement is affected by the environment, so it may need to be debugged according to the use environment.
Page 25
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Switch Settings-Alarm Settings-Intelligent Analysis-Body temperature detection-Blackbody Param, put a check mark in front of "Blackbody real-time Calibration", use the mouse to draw the detection area, and the frame for blackbody calibration should be drawn in blackbody. Set "Blackbody Temperature" to match the actual blackbody temperature.
Page 26
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (4) Precautions 1. Our thermal imaging temperature measurement products can be continuously operated continuously. If the power is off and restarted, it needs to warm up for half an hour, and the temperature of the standby can be accurately measured before the ambient temperature stabilizes.
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Chapter 5 Instructions for software (1) Software Installation You can obtain the client-side temperature measurement software through the attached accessories or by contacting technical support or sales personnel. Double-click to run the "HTS2000" software installation package and install the software as prompted.
Page 28
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (2) Client login Double-click the software shortcut to bring up the login interface, and enter your username and password to log in. User Name: admin Password: Abc.12345 Enter the main interface after login...
Page 29
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (3) Video Manager Enter the "Video Manager" interface, click the "Add" button, pop up the Add Device Information box, enter the device IP, User, Password, and click Save to complete the device addition. Click the "Delete" button to delete the device.
Page 30
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Click the " " icon on the right side of the device to pop up the detection area drawing window. After drawing the detection area with the left mouse button, click Save.
Page 31
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (5) Body Temperature Enter the "Body Temperature" interface. After the device is online, it will automatically connect to the video. The temperature detection interface has two parts, the left side displays the real-time video and the right side displays the alarm information.
Page 32
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera (7) Alarm configuration As shown in the figure, click "Setup" to enter the configuration interface. a. Configure the alarm capture path: Enter the "Base Config" interface, select the appropriate storage path, and click Save.
Page 33
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera c. Configure the partial cutout size of the alarm: Enter the "Advanced Config" interface, modify the "Crop Above" , "Crop Below", "Right Crop"and "Left Crop", and click Save. It can be adjusted to an appropriate value according to actual needs.
G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera Chapter 6 Warranty and After sales 1. Customer satisfaction is what we’ve been pursing all along and quality is what brought our company prosperity. The thermal screening camera cameras manufactured by our company integrates independent technology and unique design.