10 Configuration
10.1 To set a different address
CTXM15+FTXM20~42+ATXM20~35R2/5V1B + FTXM50~71R2V1B +
ATXM50R2V1B
Daikin room air conditioner
4P518023-8G – 2020.06
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1 Remove the cover and the batteries from the user interface.
2 Cut the address jumper J4.
a
Address jumper J4
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3 Turn the power supply on.
4 Press
and
5 Press
, select and press
Result: The operation lamp will start to blink.
a
Operation lamp
b
Indoor unit ON/OFF switch
6 Press the indoor unit ON/OFF switch while the operation lamp is blinking.
Address jumper
Factory setting
After cutting with nippers
simultaneously.
.
Address
1
2
10
Configuration
|
a
a
b
ON/
OFF
Installer reference guide
45