Resol SBS 2000 Manual For The Specialised Craftsman
Resol SBS 2000 Manual For The Specialised Craftsman

Resol SBS 2000 Manual For The Specialised Craftsman

Filling and flushing station

Advertisement

Quick Links

SBS 2000
Filling and flushing station
Manual for the
specialised craftsman
Connection
Operation
Thank you for buying this RESOL product.
Please read this manual carefully to get the best performance from this unit.
Please keep this manual carefully.
en
Manual
www.resol.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SBS 2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Resol SBS 2000

  • Page 1 SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Manual Please read this manual carefully to get the best performance from this unit. Please keep this manual carefully. www.resol.com...
  • Page 2 CE mark. The Declaration of Conformity Arrows indicate instruction steps that should be is available upon request, please contact carried out. RESOL. Disposal Dispose of the packaging in an environmentally sound manner. Dispose of old appliances in an environmentally sound manner.
  • Page 3 – and the safe, quick and clean The user must make sure that the SBS 2000 filling and way to complete filling and flushing work. flushing station is suitable for the fluid in use.
  • Page 4 Connection examples Filling and fl ushing unit Filling and fl ushing station 12 12...
  • Page 5 Operation Flushing and filling the solar system Disconnect the expansion vessel from the solar thermal system. WARNING! Risk of scalding! If the medium enters strongly heated, em- pty collectors, pressure surges caused by vaporisation can occur. In order to prevent the medium from boiling in the collectors, do not fill or flush the system during Connect the pressure hose of the filling and flush-...
  • Page 6 During flushing, bleed the solar thermal system Set the operating pressure of the solar thermal Flushing heating systems several times until the discharged solar fluid is free system (approx. 0.5 bar higher than the inlet pres- Connect the pressure hose of the flushing and fill- of air bubbles sure of the expansion vessel or the value recom- ing station to the filling valve of the system.
  • Page 7 Troubleshooting Problem Possible causes Pump does not prime Pump defective Flushing hose or dirt fi lter blocked Too much air inside the pump In this case, the pump can be vented by means of the screw at its front side (see fi g.) vent screw Pump does not build up pressure Pump defective...
  • Page 8 - they only represent use outside the copyright requires the approval of RESOL - Elektronische Rege- some examples. They can only be used at your own risk. No liability is assumed for lungen GmbH.

Table of Contents