HEALTH AND SAFETY WARNING As the dehumidifier embodies electrical and rotational equipment, ONLY competent persons should carry out any work on this type of machine. (SEE GUARANTEE) CONTENTS HEATH AND SAFETY WARNING ..........4 AIR/WATER HEAT PUMPS ............5 NOTE THAT WHEN A HEAT PUMP IS CHILLING THE CYCLE IS REVERSED ............6 THE HEAT PUMP CYCLE ............6 INSTALLATION ................7...
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC HEALTH AND SAFETY WARNING This appliance can be used by children from eight years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
AIR/WATER HEAT PUMPS MODELS COVERED IN THIS MANUAL HC HEAT PUMPS These heat pumps are heater chillers, designed for areas of the world where the ambient temperature can vary from 7ºC to 50°C. The pool water is heated when the ambient temperature is low and cooled when the ambient temperature is high, enabling the user to enjoy the pool throughout the year.
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC THE HEAT PUMP CYCLE The CALOREX Swimming Pool Heat Pumps provides thermodynamic heating by means of a vapour compression cycle, (similar to that employed in a conventional refrigerator), in addition to operating as an active solar collector. 2 The COMPRESSOR where it is compressed and upgraded 1 The EVAPORATOR collects the heat from the outside ambient air, to a much higher temperature.
INSTALLATION 1 SITING 1. Ensure heat pump on site is as ordered, i.e. model, electrical supply and factory fitted options. 2. Inspect unit for damage, in particular inspect the evaporator (finned side) to ensure that it is undamaged. (Minor indentations in the fins do not affect performance).
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC 2 AIR FLOW Due consideration must be given to air flow, i.e. do not obstruct inlet or outlet and ensure discharge air cannot re-circulate to inlet. (See figures 1 and 2). FIGURE 2 FIGURE 1 TYPICAL INSIDE OR PLANTROOM INSTALLATION TYPICAL OUTSIDE INSTALLATION...
3. PLUMBING a. Calorex ‘34’ range Heat Pumps have water inlet/outlet connections as follows: 634/1234 models ¾ “ BSP parallel, male.(with ¾” BSPF x 1½” ABS male adaptors supplied loose). 1834 models 1½” BSP parallel, male. PP22BC ¾” BSP parallel, male or 50mm The machine is supplied with bungs fitted in the water connection fittings.
Page 10
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC IMPORTANT 1. Maximum pressure of water in heat pump circuit should not exceed 3.5kg/ (50 psi) FOR POOL APPLICATIONS THE FOLLOWING ALSO APPLY 2. All Pool Purifying Devices and Chemical Injection Systems to be fitted down stream of heat pump unless installation is as per Filter dosing.
4. DETERMINING WATER FLOW MODELS 634/1234 PLUMBING. Machine must be plumbed in bypass, see diagrams below (Label on side of Adjust gate valve to give required flow rate as indicated through window on machine). side of machine. WINDOW 33 l/m POOL POOL WATER OUT...
Page 12
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC DETERMINING WATER FLOW AW1834BHC FLOW METER METHOD (SEE FIG 3). Ensure isolation valves ‘A’ and ‘B’ and bypass valve ‘C’ are fully open. Slowly close down bypass valve ‘C’ until correct flow rate is shown on the flow meter. (See data sheets on pages 39 and 40) Remove handle and lock off valve ‘C’.
Page 13
DETERMINING THE WATER FLOW PP22BC The heat pump is fitted with a water flow switch which inhibits the operation of the heat pump when the water flow is less than the figure shown in the table below. MODEL Flow rates for water pressure switch Machine starts working when the Machine stops working when the flow rate rises above L/hour...
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC 5. WATER SCHEMATICS POOL WATER SCHEMATIC (STANDARD) ENSURE POOL FILTRATION PUMP SELECTION ALLOWS FOR ALL SYSTEM RESISTANCE POOL SANITISER OR CHEMICAL DOSING POSITION AFTER CALOREX HEATER IF FITTED FLOW CALOREX SETTING PRESSURE FLOW GAUGES SETTING METHOD...
Page 15
TYPICAL INSTALLATION FOR CALOREX HOT WATER HEAT PUMP (INDUSTRIAL USE) HOT WATER SUPPLY STORAGE TANK CLOSED TYPE MAKE UP COLD WATER HOT WATER RETURN PUMP FLOW SETTING PRESSURE GAUGES CALOREX METHOD HEAT PUMP FLOW SETTING FLOW METER METHOD CALOREX ISOLATING VALVE A ISOLATING VALVE C...
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC ELECTROLYTIC CORROSION IN SWIMMING POOLS Electrolytic corrosion will occur when dissimilar metals that are in contact with each other create a potential difference between themselves. Sometimes separated by a conductive substance known as an electrolyte, the dissimilar metals will create a small voltage (potential difference) that allows the ions of one material to pass to the other.
30mA trip separate from any other associated equipment. INCONSISTENT ELECTRICAL SUPPLY The following limits of operation must not be exceeded if Dantherm Ltd. machines are to be guaranteed either in performance or warranty terms: Minimum...
Page 18
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC LOCATION OF ELECTRICAL SUPPLY CONNECTIONS Fig. 4A CALOREX HEAT PUMP AW634, WA634ACL/ACH, AW1234BHC, WA1222AC/BC LOOSEN THE 8 SCREWS AND LIFT OFF TOP COVER. (COVER IS RETAINED WITH CAPTIVE FASTENERS) ELECTRIC BOX ACCESS MAINS IN AT SIDE 1 PHASE 230V ~ 1N 50Hz ELECTRIC BOX...
Page 19
Fig. 4B CALOREX HEAT PUMP AW1834BHC Remove front 1834 mains terminal service panel block and ear ing point 1/4 turn fasteners) (also external interlock) 1 2 3 4 5 6 7 Pool pump interlock flow switch Mains supply in or so start INTERLOCK All units have an interlock incorporated innt othe control circuit, brought out to two terminals.
Page 20
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC PP22BC CALOREX CHILLER BRACKET RIVETTED TO COVER LIFT COVER OFF AT THIS END FITS THROUGH SLOT IN PANEL LOOSEN CAPTIVE SCREWS (2) TO REMOVE INNER COVER ELECTRIC AT THIS END FROM TOP OF STAT ELECTRIC BOX UNDO THE 2 SCREWS AND SLIDE...
CHANGING THE POSITION OF THE DIGITAL THERMOSTAT ON A PP22BC CHILLER If the thermostat is not easily visible when the machine is installed, the position of the thermostat and the “dummy thermostat” can be exchanged. This can be done in easy stages, but should be done by a competent person. 1.
Page 22
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC Fig. 5A RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP (1Ø or 3Ø) WITH SINGLE PHASE WATER PUMP OF MAXIMUM ¾ H.P. AND ENERGY MANAGEMENT CONTROLLER SINGLE PHASE SWITCHED FUSE ISOLATOR 13AMP SUPPLY 230V WITHIN 2m OF HEAT PUMP AND FUSED TO SUIT SIZED IN ACCORDANCE...
Page 23
Fig. 7 RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP (1Ø or 3Ø) WITH THREE PHASE WATER PUMP AND ENERGY MANAGEMENT CONTROLLER THREE PHASE SUPPLY SINGLE PHASE SWITCHED FUSE ISOLATOR WITHIN TO SUIT CAPACITY 13A SUPPLY 230V 2m OF HEAT PUMP AND SIZED IN OF WATER PUMP FUSED AT 1 AMP ACCORDANCE WITH DATA SHEET...
Page 24
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC Fig. 9 RECOMMENDED ELECTRICAL INSTALLATION FOR CALOREX HEAT PUMP (1Ø or 3Ø) WITH SINGLE PHASE WATER PUMP LARGER THAN 3/4 HP. SINGLE PHASE SUPPLY TO SUIT SWITCHED FUSE ISOLATOR WITHIN CAPACITY OF 2m OF HEAT PUMP AND SIZED IN WATER PUMP ACCORDANCE WITH DATA SHEET CALOREX...
POOL PUMP SYNCHRONISING A POOL PUMP WITH A PP22BC CHILLER For installations where the filter pump, which also provides water to your chiller, is controlled by a time clock (supplied by the installer) your Calorex chiller can override “pump off” periods set on the time clock so that the filter pump will run if your swimming pool requires chilling.
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC ELECTRICAL CIRCUIT DIAGRAMS WA634ACH SINGLE PHASE (230V ~ 1 N 50Hz) FUSE RATINGS MODEL FUSE RUN CAP SOFT WA634 5 AMP START CONTACTOR N/O) FITTED R(P) N/O) S(A) COMPRESSOR (N/O) RELAY/HARD START CAP IF FITTED HOURS (N/O)
Page 27
WA1222AC SINGLE PHASE (230V ~ 1 N 50Hz) SOFT START RUN CAP CONTACTOR FITTED COMPRESSOR EVAP PRESSURE DELAY COMPRESSOR PRESSURE LIMIT LIMIT SWITCH AUX N/O VALVE TIMER POOL STAT FAN CAP FAN MOTOR INTERLOCK TERMINALS SMART CLOCK FEED TERMINALS SOFT START THERMAL FAULT LIGHT...
Page 28
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC (R407c UNITS) WA1234BC THREE PHASE (400V ~ 3 N 50Hz) SOFT START IF FITTED CONTACTOR COMPRESSOR DELAY TIMER FAN CAP POOL STAT RELAY CUT OUT FAN FUSE FAN MOTOR INTERLOCK TERMINALS SMART CLOCK FEED TERMINALS SOFT START FAULT LAMP...
Page 29
AW634AHC SINGLE PHASE (230V ~1N 50Hz) RUN CAP SOFT START CONTACTOR FITTED R(P) S(A) COMPRESSOR RELAY/HARD START CAP (IF FITTED) DELAY TIMER CRANKCASE HEATER (IF FITTED) HOURS LIQUID RUN METER SHUT OFF (IF FITTED) DEFROST DEFROST STAT LIGHT FAN CAP CHILL LIGHT SOFT START THERMAL...
Page 30
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC WA634ACL SINGLE PHASE (230V ~1N 50Hz) FUSE RATINGS RUN CAP MODEL FUSE SOFT WA634 5 AMP CONTACTOR START (N/O) R(P) FITTED S(A) (N/O) COMPRESSOR RELAY/HARD START CAP IF FITTED DELAY TIMER HOURS CRANKCASE HEATER RUN METER IF FITTED (IF FITTED)
Page 31
AW1234BHC THREE PHASE (400V ~3N 50Hz) ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION FUSE RATINGS CIRCUIT FULLY CHARGED. CONTROL MODEL FUSE FUSES WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY. AW1234BHC SOFT START 2 (N/O) 4 (N/O)
Page 32
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC AW1834BHC THREE PHASE (400V ~3N 50Hz) OVERLOAD SETTINGS FUSE SIZES MODEL COMPRESSOR MODEL TMBLK No. 12,13,14 15,16,17 18,19,20 AW1834BHC 1.4A AW1834BHC FUSE OVER FUSES CONTACTORS LOADS COMPRESSOR DELAY TIMER COMP AUX VALVE,COIL E (NC) (LIQUID LINE SHUT OFF)
Page 33
PP22BC THREE PHASE (400V ~3N 50Hz) SOFT START CONTACTOR O/LOAD FITTED COMPRESSOR MODEL CONTROL CRANK CASE HEATER PP22BC 2.5A OVERLOAD SETTINGS MODEL COMPRESSOR PP22BC COMPRESSOR O/LOAD ALARM SOFT START THERMAL OVERLOAD & FAULT LIGHT IF FITTED STAT SENSOR (WATER TEMP) COMPRESSOR O/LOAD ALARM CHILL...
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC CONTROLS AND INDICATION LAMPS THERMOSTAT The thermostat will be marked TLZ11 (WA634ACH and WA634ACL) Adjustable digital thermostat, controls pool water temperature at the required level. Adjustable dial thermostat controls & maintains water temperature at required Press and release key ‘P’...
Page 35
DIGITAL THERMOSTAT IN THE PP22BC An adjustable digital thermostat controls and maintains the water temperature and incorporates the indicator lamps. Press and release the P key to display required temperature. To alter required temperature press the up or down keys. After 5 seconds the display reverts to actual water temperature.
Any sign of abnormal operation such as water dripping should be reported immediately to an installer or Dantherm Ltd. If in doubt or if advice required contact the Dantherm Group UK Service Department. Telephone (01621) 856 611 (option 4).
Page 37
USER CHECKLIST FOR AW1234/1834HC MODE LAMP COLOUR ACTION HEAT COOL UNIT DOES NOT OPERATE ALL LAMPS Check Mains supply - external fuses - isolator etc. - check internal control fuse MAINS Check thermostat setting TEMP O.K. Check compressor/fan fuses OTHER LAMPS Standby' switch is 'ON' (if fitted) MAINS Check water and air flows are not...
Page 38
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC USER CHECKLIST FOR PP22BC SYMBOL DESCRIPTION LAMP ON LAMP FLASHING LAMP OFF Water chilling demand. No demand for water Demand for water Water chilling Compressor delay timer not timed chilling/ demand chilling satisfied Fan running Fan not running.
3) Pool water to have correct balance, pH 7.2 - 7.8. Free Chlorine 1.0 - 2.0 ppm domestic, 3.0 - 6.0 commercial. 4) Allow 500mm clearance to service panels 5) Dantherm Ltd. reserves the right to change or modify models without prior notice 6) Global warming potential (GWP) R407c 1774, R134a 1430...
Page 40
3) Pool water to have correct balance, pH 7.2 - 7.8. Free Chlorine 1.0 - 2.0 ppm domestic, 3.0 - 6.0 commercial. 4) Allow 500mm clearance to service panels 5) Dantherm Ltd. reserves the right to change or modify models without prior notice 6) Global warming potential (GWP) R407c 1774, R134a 1430...
WINTERISING PROCEDURE START UP PROCEDURE AFTER WINTERISATION 1. Replace covers (if not fitted). WARNING. Isolate machine before opening! As the heat pump embodies electrical and rotational equipment, it is recommended 2. Remove front grille -- using soft brush clean finned surfaces of heat for your own safety that a competent person carries out the pump.
4.1. current procedures as defined by Dantherm Ltd. If in doubt or if advice is required please contact the Dantherm Group The heat pump has been worked upon or is adjusted by anyone other UK Service Department by calling 01621 856 611 (option 4) or than a person authorised to do so by Dantherm Ltd.
The operator of the unit is responsible for seeing that the test is carried out. For machines affected see datasheet. A sample log sheet can be seen below. Dantherm Ltd. is an F-Gas registered company. Certificate number REF1011570. General Information...