Ascensia Diabetes Care Contour Next User Manual
Hide thumbs Also See for Contour Next:

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Contour Next and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ascensia Diabetes Care Contour Next

  • Page 2 INDICATIONS FOR USE • Do not calibrate a continuous glucose monitoring device from an Alternative Site test result. The C blood glucose monitoring system is an over- ® ontour • Do not calculate an insulin dose based on an Alternative Site test the-counter (OTC) device utilized by persons with diabetes in result.
  • Page 3 US Department of Health and Human Services; 8/23/2010. • Check the expiration dates on your test strips and control http://www.cdc.gov/injectionsafety/Fingerstick-DevicesBGM.html solution. Do not use the test strips or control solution if the • The lancing device should not be used for assisted blood draws expiration date printed on the bottle label and carton has passed.
  • Page 4: Table Of Contents

    Table of Contents • The C blood glucose monitoring system has a ® ontour measuring range of 20 mg/dL to 600 mg/dL. For results over 600 mg/dL or under 20 mg/dL: Intended Use, Important Safety Information ......i ❖ Your C Meter ...........2 ®...
  • Page 5 ®...
  • Page 6 ®...
  • Page 7 To Change Time To Change Date SETUP SETUP Time: Date: 1. If you want to change the date, use 1:03 8/23/12 1. If you want to change the time, use the ▼ button to select Change and the ▼ button to select Change and press the OK button.
  • Page 8 Target Ranges The next screens display the preset blood sugar Target TARGETS ranges for Fasting, Before Meal and After Meal blood sugar. Fasting: 3. The preset Fasting Target range will 70 - 130 mg/dL appear (70 - 130 mg/dL). WARNING Press the OK button to continue to Discuss your Target ranges with your health the Before Meal Target range.
  • Page 9: Getting Ready To Test

    Getting Ready to Test Preparing the Lancing Device The lancing device graphics are for illustration purposes Read your C meter user guide, the ® ontour only. Your lancing device may look different. Refer to lancing device insert and all instructional materials your lancing device insert for detailed instructions on provided in your meter kit before testing.
  • Page 10 ®...
  • Page 11 ®...
  • Page 12: Test Results

    AutoLog Test Results Your meter comes with an AutoLog feature that lets you Test Results with AutoLog On mark your test result as No Mark, Fasting, Before Meal and • Your C meter comes with AutoLog on. ® ontour After Meal. You can turn AutoLog off using the Setup menu No Mark –...
  • Page 13 Test Results with AutoLog Off 10/13/12 10:20 PM Testing... After applying blood to the test strip mg/dL After making your selection, your test when AutoLog is Off, your result will result appears. Press the OK button to appear. You may see the 5 second move to See Options.
  • Page 14 ®...
  • Page 15 ®...
  • Page 16: Expected Test Result Values

    Ejecting and Disposing of the Used Lancet Expected Test Result Values 1. Do not use your fingers Blood sugar values will vary depending on food intake, to remove the lancet medication dosages, health, stress, or activity. Non-diabetic from the lancing device. plasma glucose concentrations should be <...
  • Page 17 Quality Control 1. Remove the test strip from the bottle and firmly snap the • Shake the control solution bottle well, lid closed. about 15 times before every use. 2. Hold the test strip with the gray square end facing up. •...
  • Page 18 ®...
  • Page 19 Turning Off a Reminder After Testing 1. Press the OK button and if the Countdown is currently on, the screen will show Reminder in. Reminder in: 2 hrs 30 mins REMINDER A screen confirms the Reminder 2. To stop the Countdown, select Stop. Countdown time.
  • Page 20: Logbook

    Logbook Notes Reviewing the Logbook Adding a Note The Logbook contains blood sugar test results and notes You may add Notes to your test result that may help explain that you have made to those test results. The Logbook will results.
  • Page 21: Trends (Averages And Summaries)

    Trends (Averages and Summaries) The Trends feature displays your average and a summary Before Meal of your test results as they compare to your targets, over a Average (14 Day) period of time that you select. The options available are 7, 4.
  • Page 22 Viewing Trends with AutoLog Off If you have AutoLog turned off, you will only see trends for Overall 8. Continue to press the ▼ button to your overall Target. Average (14 Day) see your Overall 14-day Average. 1. Turn on the meter by pressing and holding the OK button. mg/dL This example includes ALL your 2.
  • Page 23 ®...
  • Page 24 Date 1. Press and hold the OK button until DATE DATE the meter turns on. mm/dd/yy Change Day: 8/23/12 9/23/12 2. From the Setup Menu, use the ▼ 7. Change day by using the ▲ or ▼ button to highlight the Date. Press the button.
  • Page 25 TIME Time set: Select Time Format: 1:03 2:05 8. Done will be highlighted. Press the 4. Change the time format if needed. OK button. Press the OK button. 12-hour clock Done 24-hour clock Change Sound TIME Change hour: Your meter comes with the Sound turned on. Certain error 5.
  • Page 26: Autolog

    AutoLog Blood Sugar Target Ranges Your meter comes with AutoLog turned On. Your C meter comes preset with blood sugar ® ontour Target ranges for Fasting, Before Meal, and After Meal AutoLog Settings results. The preset range is 70 - 130 mg/dL for Fasting and Before Meal, and 70 - 180 mg/dL for After Meal.
  • Page 27 TARGETS TARGETS 6. Use the ▲ or ▼ button to change the Fasting: highlighted value. When you see the Before Meal: 10. To change the Target, press the ▼ 70 - 130 mg/dL value you want, press the OK button, button to highlight Change and –...
  • Page 28 Setting Targets When AutoLog is OFF 14. The After Meal Target range will TARGETS SETUP appear (70 - 180 mg/dL). You can 1. Press and hold the OK button until Accept the highlighted Target by Sound After Meal: the meter turns on. pressing the OK button.
  • Page 29 Language TARGETS 12:35 AM Logbook Overall: 5. To change the preset Target, use the 1. Press and hold the OK button until 70 - 180 mg/dL Trends ▼ button to highlight Change and the meter turns on. Setup press the OK button. Accept Change SETUP...
  • Page 30: Caring For Your Meter

    Display Background Customer Service (on the Setup Menu) You can change the Display to show black background with This option is needed only if you are speaking to a Customer white text, or white background with black text. Service representative. It is not for use at any other time. The Customer Service representative will give you a code to use SETUP to verify certain settings.
  • Page 31: Your C Ontour ® N Ext Meter

    Cleaning and Disinfection cleaning and disinfection without damage. You should contact Customer Service for assistance if your device malfunctions Your C meter should be cleaned and ® ontour for any cause or if you notice any changes in the meter case disinfected once a week.
  • Page 32 ®...
  • Page 33 ®...
  • Page 34: Error Detection Displays

    Error Detection Displays Strip Errors The meter display screen provides information for test result, (E02) (E03) (E04) strip, or system errors. Used Test Strip Strip Upside Down Wrong Strip If there is an error the meter will beep 2 times. Follow the Remove used strip.
  • Page 35: System Support Information

    System Support Information Parts Information Speak to a Customer Service representative before returning To replace missing parts or reorder supplies, call Customer your meter for any reason. See the back cover for contact Service. See the back cover for contact information. information.
  • Page 36: Technical Information

    Technical Information Technical Information Accuracy Precision The C blood glucose monitoring system was To assess precision under repeatability conditions, venous ® ontour tested using 100 capillary blood samples and three lots of human blood samples were pooled and adjusted to a test strips.
  • Page 37: Symptoms Of High Or Low Blood Glucose

    Symptoms of High or Low Blood Glucose Specifications You can better understand your test results by being aware Test Sample: Capillary whole blood of the symptoms of high or low blood glucose. According Test Result: Glucose measurements are reported as to the American Diabetes Association, some of the most plasma equivalents.
  • Page 38 References 1. Wickham NWR, et al. Unreliability of capillary blood Principles of the Procedure: The C blood ® ontour glucose in peripheral vascular disease. Practical Diabetes. glucose test is based on measurement of electrical current 1986;3(2):100. caused by the reaction of the glucose with the reagents on the electrode of the strip.
  • Page 39: Warranty

    Some States do not allow the exclusion or limitation of solutions). incidental or consequential damages, so the above limitation 3. Ascensia Diabetes Care reserves the right to make or exclusion may not apply to you. This warranty gives you changes in the design of this instrument without obligation...
  • Page 40: Index

    Index After Meal Marker (AutoLog) ............16 Specifications ................... 67 Alternative Site Testing (AST) ............20 Summaries (Trends) ................34 AutoLog (Meal Markers) ..............16 Symptoms of High or Low Blood Glucose ........66 Averages (Trends) ................34 System Support Information ............62 Batteries ...................
  • Page 41 Distributed by: Ascensia Diabetes Care US, Inc. 5 Wood Hollow Road Parsippany, NJ 07054 www.diabetes.ascensia.com Customer Service: 800-348-8100 Available Monday through Sunday, from 8:00 am through 12:00 Midnight, Eastern Time. For more information on patents, and related licenses, see: www.patents.ascensia.com...

Table of Contents