Ocean Optics DH-2000 Series Installation And Operation Manual

Ocean Optics DH-2000 Series Installation And Operation Manual

Deuterium-halogen light source

Advertisement

DH-2000 Deuterium-Halogen Light
Source
Installation and Operation Manual
For Products: DH-2000 / DH-2000-BAL / DH-2000-DUV /
DH-2000-S / DH-2000-S-DUV / DH-2000-FHS, DH-2000-FHS-DUV
/DH-2000-S-DUV-TTL
Document: 000-10000-025-02-201510
WARNING
Protective Eye Wear Must Be Worn When
Using This Instrument -
Intense Ultraviolet Radiation Present
See Important Safety Notices inside.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DH-2000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ocean Optics DH-2000 Series

  • Page 1 DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual For Products: DH-2000 / DH-2000-BAL / DH-2000-DUV / DH-2000-S / DH-2000-S-DUV / DH-2000-FHS, DH-2000-FHS-DUV /DH-2000-S-DUV-TTL Document: 000-10000-025-02-201510 Protective Eye Wear Must Be Worn When Using This Instrument - Intense Ultraviolet Radiation Present See Important Safety Notices inside.
  • Page 2 Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an “as is” basis. Ocean Optics, Inc. shall have neither liability nor responsibility to any person or entity with respect to any loss or...
  • Page 3 No other manufacturer offers such a solid guarantee of quality and reliability. The Ocean Optics 3-Year Warranty applies to Ocean Optics equipment (excluding OEM configurations) purchased on or after July 1, 2010. The warranty covers parts and labor needed to repair manufacturing defects that occur during the warranty period.
  • Page 4 Important Safety Notices 000-10000-025-02-201510...
  • Page 5: Table Of Contents

    Table of Contents About This Manual ......................iii Document Purpose and Intended Audience ................iii What’s New in this Document ....................iii Document Summary ........................iii Product-Related Documentation ....................iii Upgrades ........................iii Chapter 1: Setup ................1 Overview ........................1 Unpacking the DH-2000 ....................
  • Page 6 Table of Contents Chapter 4: Troubleshooting .............. 11 Deuterium Lamp ......................11 Halogen Lamp ....................... 12 Appendix A: Maintenance ..............13 Overview ........................13 Bulb Replacement ......................13 Replacing the Deuterium Bulb for All Models Except DH-2000-BAL ........14 Replacing the Deuterium Bulb for DH-2000-BAL Model ............14 Replacing the Halogen Bulb for All Models Except DH-2000-BAL ...........
  • Page 7: About This Manual

    Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Ocean Optics and obtain a Return Merchandise 000-10000-025-02-201510...
  • Page 8 About This Manual Authorization (RMA) number. Please contact Ocean Optics for specific instructions when returning a product. 000-10000-025-02-201510...
  • Page 9: Chapter 1: Setup

    Chapter 1 Setup Overview The following sections provide instructions on unpacking and setting up your DH-2000 Light Source. Before using the DH-2000 for the first time check for transport damage. Be sure to adhere to all warnings on the unit and in this manual. Unpacking the DH-2000 ►...
  • Page 10: Contents

    1: Setup Contents Your DH-2000 package should contain the following:  DH-2000 unit Power cord  One IC-DB15-2 interface cable for shutter operation (DH-2000-S, DH-2000-BAL, DH-2000-  FHS, and DH-2000-S-DUV-TTL models only) UV safety goggles  Connecting the Cables ► Procedure 1.
  • Page 11: Chapter 2: Dh-2000 Specifications

    Chapter 2 DH-2000 Specifications This section provides information on the operating environment, physical controls, and dimensions of the DH-2000. Operating Environment The following table provides information on optimizing the operating environment of your DH-2000 unit. Operating Environment The DH-2000 Unit . . . Moisture Is designed for operation in dry rooms only.
  • Page 12: Front Panel

    2: DH-2000 Specifications Front Panel Halogen On/Off Deuterium On/Off Mechanical Protection –SMA Connector Power LED Component Description Press the blue DEUTERIUM button to turn the Deuterium lamp on or off. The bulb requires a warm-up time of 20 seconds before the Deuterium lamp is illuminated. Deuterium On/Off You must allow the bulb to warm up to receive accurate data from the lamp.
  • Page 13: Rear Panel

    Type Sign – Main connection – Max. Ambient. Temperature – Warnings – CE-Marking On TTL Connector-equipped DH-2000 Series lamps, this connector allows for 15-pin TTL Connector external TTL control of lamp shuttering (-S and _BAL models only) and individual (not shown) lamp operation (TTL model only).
  • Page 14: Specifications

    CE; VDI/VDE 0160; EN 61010 Weight Approximately 6 kg Size 150 x 135 x 319 mm Pinout Information The following table contains pinout information for the DH-2000 Series of Lamps. Consult the appropriate column for pinout information on your lamp. 000-10000-025-02-201510...
  • Page 15: 15-Pin Connector Pinout Diagram

    2: DH-2000 Specifications If your lamp is not listed, pinout information in this chart is not applicable for your particular model. Description Deuterium Lamp – Turns the Deuterium Lamp on when 5V is applied to the pin Halogen Lamp - Turns the Halogen Lamp on when 5V is applied to the pin Ground (TTL versions only) Ground...
  • Page 16 2: DH-2000 Specifications 000-10000-025-02-201510...
  • Page 17: Chapter 3: Operating Instructions

    Chapter 3 Operating Instructions Operating the Lamp The following sections provide instructions on operating the Deuterium and Halogen lamps in the DH- 2000. The Halogen lamp is only available in the DH-2000, DH-2000-DUV, and DH-2000-BAL models. Caution The unit must operate in a horizontal position. Starting the Lamp Press the Deuterium or Halogen On/Off switch down to preheat the desired lamp.
  • Page 18 3: Operating Instructions If applications require extreme intensity stability, the Halogen lamp should be warmed up for an additional 15 minutes. Once warmed up for this amount of time, the lamp will reach specified drift values. 000-10000-025-02-201510...
  • Page 19: Chapter 4: Troubleshooting

    Chapter 4 Troubleshooting Deuterium Lamp If the power supply or Deuterium lamp does not seem to functioning properly, check the following: Issue Probable Cause Resolution Line power not present Check line voltage Power switches on, but no LEDs light. Fuse defective Check fuse Allow the Deuterium lamp to cool down (20 minutes).
  • Page 20: Halogen Lamp

    4: Troubleshooting Halogen Lamp If the Halogen lamp does not seem to functioning properly, check the following: Issue Probable Cause Resolution Wait until the Deuterium lamp Deuterium lamp is warming up Halogen lamp does not work has lit and try again after pressing On/Off switch Halogen lamp is defective Replace the Halogen lamp...
  • Page 21: Appendix A: Maintenance

    Appendix A Maintenance Overview Maintenance of your DH-2000 unit involves periodic replacing the light source bulbs, when necessary. DH2000 units produced before 2003 CANNOT be repaired or have the bulbs replaced. The bulbs for a DH2000 unit manufactured before 2003 are no longer available. See the figure beow to determine which unit you have before ordering new bulbs or requesting an RMA: Rear panel of Nonrepairable DH2000 Rear panel of Repairable DH2000...
  • Page 22: Replacing The Deuterium Bulb For All Models Except Dh-2000-Bal

    A: Maintenance WARNING Before replacing the bulb in the DH-2000, disconnect the lamp from your power source and allow the unit to cool for at least twenty minutes, if necessary. Do not touch the lamp glass directly, as contact with bare fingers will reduce the lifetime of the bulb.
  • Page 23: Replacing The Halogen Bulb For All Models Except Dh-2000-Bal

    A: Maintenance 2. Open the screws (15) with the tool (18) that is delivered with the spare bulb (16). 3. Disconnect the old bulb and connect the new Deuterium lamp only with the originally supplied connection plugs (17). 4. Reassemble the lamp housing by reversing Steps 1-3. Replacing the Halogen Bulb for All Models Except DH-2000-BAL ►...
  • Page 24 A: Maintenance 2. Remove the screw (21) with the tool (20) provided with the spare bulb (19). 3. Disconnect the old Halogen bulb from the connection plugs (18) 4. Open the screws of the cable-clamp on the lamp-side and remove the defective Halogen lamp module.
  • Page 25: Replacing The Halogen Bulb For Dh-2000-Bal Model

    A: Maintenance 6. Reattach the two cables of the Halogen lamp module to the cable-clamp. To do this, attach the Halogen lamp’s blue cable to Port 1 and the black cable to Port 2 of the connector. Replacing the Halogen Bulb for DH-2000-BAL Model ►...
  • Page 26 A: Maintenance 7. Reassemble the unit by reversing the disassembly steps. 000-10000-025-02-201510...
  • Page 27: Appendix B: Supplementary Information For Models Dh-2000-S And Dh-2000-Fhs

    Appendix B Supplementary Information for Models DH-2000-S and DH-2000-FHS Overview The following information applies to specific models of the DH-2000. Read the instructions and refer to the figures on page 23. DH-2000-S (With TTL Shutter Control) Automatic Operation Plug SUB-D 15-pin TTL connector into socket on rear of DH-2000-S. Manual Operation Manually set operating mode using the toggle switch on the front of the DH-2000-S: ...
  • Page 28: Dh-2000-Fhs (With Filter Holder And Ttl Shutter Control) And Dh-2000-Bal

    B: Supplementary Information for Models DH-2000-S and DH-2000-FHS DH-2000-FHS (With Filter Holder and TTL Shutter Control) and DH-2000-BAL TTL Function Operating Instructions Automatic Operation Plug the SUB-D 15-pin TTL connector into the socket on the rear of the DH-2000-FHS. Manual Operation Manually set operating mode using the toggle switch on the front of the DH-2000-FHS: ...
  • Page 29 B: Supplementary Information for Models DH-2000-S and DH-2000-FHS Switch Light Beam Filter Slit SUB-D 15 Pin TTL Connector Protection 000-10000-025-02-201510...
  • Page 30 B: Supplementary Information for Models DH-2000-S and DH-2000-FHS 000-10000-025-02-201510...
  • Page 31: Index

    Index manual operation, 22 operating instructions, 22 Model DH-2000-S automatic operation, 21 bulb replacement, 15 manual operation, 21 deuterium bulb, 16 deuterium bulb for DH-2000-BAL, 17 halogen bulb, 18 halogen bulb for DH-2000-BAL, 19 operating environment, 5 operating instructions, 11 lamp, 11 components, 5 front panel, 6...
  • Page 32 Index warranty, A what's new, iii 000-10000-025-02-201510...

Table of Contents