INHALTSVERZEICHNIS INHALTSVERZEICHNIS ..........................1 GLOBAL MAP ..............................2 Key Functions ..............................2 Display Functions ............................2 INSTALLATION AND COMMISSIONING OF THE SCALE ................3 Check scope of delivery ..........................3 Mains and battery operation of the scale ......................3 Adjust the scale ............................... 4 Assembling of wind shield ..........................
GLOBAL MAP Key Functions Pay attention: The switch for switching on the scale is on the right hand side below the scale Keys: Functions: ……….. Push button / Button to finalize a process Print-button in weighing mode for data transmission tp PC or printer via RS232-data interface (if interface is included), to save and quitt he presetting mode.
INSTALLATION AND COMMISSIONING OF THE SCALE Your ADE Precision Scale is a quality product. In order to achieve precise results please kindly read and follow the Operation Manual in all respects. Keep this Operating Manual careful to have this information on hand whenever you need it.
Adjust the scale Take the scale and the equipment carefully out of the carton and check it for completeness. Adjust the scale in this way that all four feet have contact with the footprint, which should be safe and even. Check the horizontal stand of the scale by the help of the bubble level which is insert (seen from the operator side) on the backside of housing.
OPERATION OF THE SCALE Weight Analysis Both, in mains and in battery operation, switch-on the scale using the right hand on the membrane keyboard arranged ON-/Off-key. The test routine starts with the indication of type and version number and starts thereupon to run downward from 999999 till 000000;...
Selection of weight unit Select between the different units of weight by pressing the UNIT key. Select by successive single pressing between the units g – ct – oz – dwt – mm - lb – dr – tl.H – tL.J –...
4. After accordance of reference quantity (on the weighing surface) and the quantity shown on the display press the button „PCS“. The single weight as well as the weight of the reference quantity has to be a minimum weight of 1d (please read. page 13, technical details). In case the weight is too low the display will show „“.
Battery Alert It is also possible to provide the scale with voltage via the integrated battery. Should the voltage be too low the battery symbol in the display will indicate. The batteries should be charged or exchanged immediately. PRESETTING OF THE SCALE Presetting mode: It is possible to set a plenty of presetting.
Setting up the maximum weight Start the presetting mode as described before. Press the UNIT-button until correspondent menu appears. Set the maximum value. Press PCS-button to change the value from left to right. The value you want to set is blinking. Press „-0-“-button to increase the value by one.
Selection of transmission way This function is active while the balance is connected with printer, computer and the relative equipment. Press PCS to choose the number of 1-8 and then press PRN to save or exit. Press UNIT to go to the next function mode selection. This function is activated, when scale is connected with printer or PC.
Disconnect all cables before transport to avoid unnecessary damages. Warranty ADE will repair or replace this product within a period of 1 years from date of delivery applying to defects occurred due to poor material or workmanship (presentation of invoice is necessary). All moveable parts e.g.
This declaration loses its validity if modifications are made to the scale without our approval. Hamburg, July 2020 ADE Germany GmbH & Co. KG Hammer Steindamm 27 – 29 D-22089 Hamburg Manufacturer: ADE Germany GmbH & Co. KG Hammer Steindamm 27-29 D – 22089 Hamburg Deutschland ...
TECHNICAL SPECIFICATIONS Model PFA1000 PFA3000 PFA6000 Capacity 1000 g 3000 g 6000 g 0.01 g 0.1 g 0.1 g Graduation = d Weighing platform Ø 130 mm 160 x 160 mm 160 x 160 mm (stainless steel) Dead weight 1.7 kg 1.5 kg 1.5 kg Dimensions (WxDxH)