Kenwood TK-3160 Service Manual page 20

Hide thumbs Also See for TK-3160:
Table of Contents

Advertisement

Item
Condition
14.BATT
BATT terminal voltage:5.9V
Detection
PTT:ON
Writing
[Wide]
15.BATT
1) BATT terminal voltage:5.5V
Detection
PTT:ON
Check
2) BATT terminal voltage:7.5V
PTT:ON
Receiver Section
Item
Condition
1.BPF Wave
TEST CH: Low
form ADJ
Low'
[Wide]
Center
High'
High
(5 points)
SSG otuput:–103 dBm(1.58µV)
2.Sesitivity
TEST CH: Low
check
Low'
[Wide]
Center
High'
High
(5 points)
SSG otuput:–116 dBm(0.35µV)
SSG MOD:3kHz
[Narrow]
TEST CH: Center
SSG otuput:–115 dBm(0.4µV)
SSG MOD:1.5kHz
3.Squelch
TEST CH: Center
tight
SSG otuput:–117 dBm(0.3µV)
writing
SSG MOD:3.0kHz
[Wide]
[Narrow]
TEST CH: Center
SSG otuput:–116 dBm(0.35µV)
SSG MOD:1.5kHz
4.Squelch
TEST CH: Center
threshold
SSG otuput:–122 dBm(0.18µV)
writing
SSG MOD:3.0kHz
[Wide]
[Narrow]
TEST CH: Center
SSG otuput:–121 dBm(0.2µV)
SSG MOD:1.5kHz
5.RSSI writing TEST CH:Center
[Wide]
SSG otuput:–124 dBm(0.14µV)
SSG MOD:off
[Narrow]
TEST CH:Center
SSG otuput:–123 dBm(0.16µV)
SSG MOD:off
ADJUSTMENT
Measurement
Test equipment
Terminal
Power meter
ANT
DVM
BATT terminal
Measurement
Test equipment
Terminal
SSG
ANT
DVM
RSSI
Oscilloscope
AF VTVM
ANT
TK-3160
Adjustment
Parts
Method
Write
Check
Adjustment
Parts
Method
Programming
RSSI MAX
Software:KPG-82D
Check
Programming
Write
Software:KPG-82D
Specifications/
Remark
BATT terminal
voltage:5.9V
LED blinks
LED does not
blink
Specifications/
Remark
12dB SINAD or
more
Squelch open
Squelch open
Squelch open
Squelch open
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

B51-8674-00

Table of Contents