User's Manual
Vet Cart

Advertisement

Table of Contents
loading

Summary of Contents for Olsen Vet Cart

  • Page 1 User’s Manual Vet Cart...
  • Page 3: Table Of Contents

    Index Index ....................................3 1 - Introduction ................................5 2 - Package Contents ..............................5 3 - Equipment Presentation ............................5 - Standard Items .............................5 - Optional Items ..............................5 4 - Parts Identification ..............................7 5 - Equipment Description and Operating ........................7 - Before Turning On the Equipment .......................7 - Turning On the Equipment ...........................7 - Base Structure .............................8 5.3.1 Air Compressor (Optional) ........................8...
  • Page 4 - Electrical Installation ..........................18 8 - Installation................................18 - Check List ..............................18 - Olsen Accredited Technical Assistance Network ..................19 9 - Cleaning and Disinfection ........................... 19 - Painted Parts ............................. 19 - Sterilization by Autoclave .......................... 19 - Curing Light ...............................
  • Page 5: Introduction

    2 - Package Contents Check out the equipment package contents: Standard Items: 1 Vet Cart 1 User Manual Vet Cart Optional Items: Electrical Micromotor Brushlesss Electrical Micromotor Ultrasonic Scaler with LED Light LED Curing Light...
  • Page 6: Parts Identification

    4 - Parts Identification A - Working Table (Item 5.5 - pg. 9) B - Electrical Panel (Item 5.5.2 - pg. 10) C - Control Panel (Item 5.5.2 – pg. 10) D - Water Tank (Item 5.2 - pág. 7) E - Base Structure (Item 5.3.2 - pág.
  • Page 7: Base Structure

    - Base Structure 5.3.1 Air Compressor (Optional) The cart may come with a compact compressor (7) (optional) to supply the compressed air needs of the pneumatic instruments and saliva ejector. The compressed air tank is the column and base (1) of the equipment, which has a electrical panel (4), manometer (2), drain (6) and safety valve (3).
  • Page 8: Working Table

    - Working Table 1 - Electrical Panel; 2 - Control Panel; 3 - Instruments Holder; 4 - Bicarbonate Reservoir; 5 - Stainless Steel Tray; 6 - Fiber Optics/Air Jet On/Off Button; The working table’s function is to provide handpieces for performing veterinary procedures. The handpieces are arranged in holders (3) and has composed of stainless-steel tray, 3-way syringe, and couplings for low and high-speed for pneumatic handpieces.
  • Page 9: Panels

    (e.g.: endo function switch) - Pneumatic Handpiece Couplings As a standard, Olsen uses the Borden terminal system in its equipment, making the Midwest system available as an option. The Borden coupling without cooling (1) is used only for the low- speed handpiece coupling.
  • Page 10: Optical Fiber Handpiece (Optional)

    the ring so it distances one indicator from the other. The completely opposite points indicate the minimum water regulation for the spray. Note: the spray adjustment is not available to pneumatic coupling without refrigeration. - Optical Fiber Handpiece (Optional) Connect the optical fiber handpiece to the coupling by attaching it to the coupling ring (1), ensuring that it is properly connected and that there is no leakage of air or water.
  • Page 11: Curing Light (Optional)

    - Curing Light (Optional) This tool was developed for polymerization and can be used for tooth bleaching. the curing light produces light radiation to solidify light sensitive resins with short duration shots. Technical Features: − Dimensions: 26 x 25 x 260 mm; −...
  • Page 12: Ultrasonic Scaler With Led Light (Optional)

    - Ultrasonic Scaler with LED Light (Optional) The ultrasonic scaler has an ultrasonic generator electronic board that, through the Piezoelectric System, provides the tip vibration, giving a high-frequency condition. When the ultrasonic scaler is triggered, it starts the tip vibration, activates the LED and opens the water passage for cooling.
  • Page 13: Ultrasonic Scaler Operating Precautions

    − Check out the vibration outside the patient's oral cavity before use. If any abnormality is found, discontinue use immediately and contact a Certified Olsen Assistance; − Always use gloves when handling the ultrasonic scaler, tips, Torque wrench and its removable covers;...
  • Page 14: Brushless Electric Micromotor (Optional)

    5.11.1 - Brushless Electric Micromotor (Optional) Technical Features: − - Power Supply: 24 VCA; − - Power Rating: ~33 W. − - Rotation Speed: 20:1 from 100 to 2.000 rpm; 1:1 from 2.000 rpm to 40.000 rpm; 1:5 from 10.000 to 200.000 rpm; −...
  • Page 15: 3-Way Syringe (Optional)

    To adjust input pneumatic pressure: use the adjustment keys (13) to set the parameter. Set maximum input pressure Set minimum activation pressure Note: the micromotor system preset by the factory according to the internal equipment pressure. It is not from 0.20 to 0.40 MPa from 0.03 to 0.10 MPa recommended to change the pressure parameters.
  • Page 16: Air Jet (Optional)

    7 - Installation Requirements - Pre-Installation The pre-installation is the suitability of the environment for the installation of the equipment. This step should be guided by Olsen authorized assistance to ensure that the installation environment is suitable to receive...
  • Page 17: Water For The Water Tank

    The equipment installation must be performed by Olsen certified technician, who will also inspect the equipment making sure it's according to what was requested, if it remains intact after having been transported, in addition, to performing a quality inspection before use, ending the process with a guidance on proper equipment operation, cleaning, and maintenance.
  • Page 18: Olsen Accredited Technical Assistance Network

    7 - Did the equipment arrived as ordered and was delivered in perfect condition? 8 - Have the castors movements been checked? - Olsen Accredited Technical Assistance Network To access the Olsen certified technical assistance network for installation and maintenance or contact us by e-mail export3@olsen.odo.br or if you prefer +55 48 2106 6000.
  • Page 19: Curing Light

    Curing light’s body cleaning must be done with neutral detergent or 70% alcohol. Olsen is not responsible for defects, deformities, spots on or abnormalities caused by improper use of chemical products, contact with tissues, leather, disposable gloves, inks, pigmented detergents and other organic or synthetic products.
  • Page 20: Technical Features

    covers and metal parts; − Remove the handpieces that were used during the day (high and low-speed) and provide their lubrication. After the lubrication, sterilize them; − Remove the other handpieces used during the day: prophylaxis handpiece, 3-way syringe tip, the transducer and its tips, curing light tips and provide the sterilization of each one;...
  • Page 21: Applied Parts

    Weight: − Net: 28,5 kg; − Gross: 38 Kg. Items in compliance with requirements 6.1 and 6.2 of IEC 60601-1-2:2010: Power cable: Flexible Cable PP Circular 500 V 3 x 1 mm 247-5 NM 53-C5; Tri-polar Male Plug 10 A - 250 V. Ultrasonic scaler transducer: Manufacturer: Guilin Woodpecker Medical Handpiece Co;...
  • Page 22: Symbology

    11 – Symbology...
  • Page 23 The symbology complies with standards IEC 60601-1 and IEC 60878.
  • Page 24: Dimensional

    12 – Dimensional Measurements in mm...
  • Page 25: Important Notes

    13 - Important Notes The reproduction and distribution of these instructions can only be made with prior permission from Olsen Indústria e Comércio S.A. The technical features of the products described in this manual correspond to the time of its publication.
  • Page 26: Disposal

    Turn Off the On/Off switch on the electrical panel before replacing the fuse. Do not install or use any electrical equipment over or near the Olsen’s Cart with Compressor. If necessary, the Cart with Compressor must be checked to see if it is functioning normally in the configuration in which it will be used.
  • Page 27: Troubleshooting

    5º - The air compressor is not working properly. 5º - Call the air compressor assistance. 6º - There’s a blocking in the pneumatic 6º - Contact Olsen certified assistance. system. 1º - There’s looseness on the handpiece 1º - Attach the handpiece correctly.
  • Page 28: Preventive Review

    +55 48 2106 6000. 15 - Preventive Review In order to extend your equipment’s lifespan, Olsen has created the extended warranty system by performing scheduled service maintenance. During the service maintenance, the technician will evaluate the equipment’s general maintenance condition, as well as the monitoring of component wear and if there is a need for lubrication.
  • Page 29: Registro De Revisão

    Adulterations in the purchase, installation or services document; d) Installation or technical assistance made by a person not authorized by Olsen; e) Failure to install the equipment for more than 90 days, counted from the purchasing date contained in the invoice;...
  • Page 30: Message From The President

    Our company will always be open to all those who prefer Olsen products, for any necessary information and technical assistance, but especially for comments regarding the relationship with customers.
  • Page 31 __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________...
  • Page 33 +55 48 2106 6000 export3@olsen.odo.br Registration at Ministry of Health 1028130009 Technician in Charge Eng. Cleber da Costa - CREA SC: S1 116283-5 Cod 5409212 - Rev 03 – 22/03/2021...