Download Print this page

Jadever JIF-2002 Manual

Weighing indicator & controller

Advertisement

Quick Links

CHAPTER 1
INTRODUCTION
JIF-2002 WEIGHING INDICATOR&CONTROLLER
1

Advertisement

loading

Summary of Contents for Jadever JIF-2002

  • Page 1 CHAPTER 1 INTRODUCTION JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 2 1-1 Welcome The JIF-2002 weighing indicator is a model of breakthrough high resolution. With set-point codes, this model makes batching control an easy task. With relatively compact size, JIF-2002 performs a remarkable accuracy and speed. With sincere gratitude for your using our products, once any question or problems occurred, please contact us immediately for further services.
  • Page 3 Optional: OP-01 I/O Interface OP-02 RS-232 or RS422/485 OP-03 Printer Interface OP-04 Binary Coded Decimal OP-05 Analog Output 4∼ 20 mA OP-06 Analog Output 0∼ 10 V JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 4 KEY LOCK: Disable unimportant or useless keys. SYSTEM PARAMETER BACKUP: JIF-2002 another copy of preset parameters. SYSTEM PARAMETER RESTORATION: Restore preset parameters. SYSTEM INITIALIZE: Re-install resets the JIF-2002 to the initial factory setting and starts the operation. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 5 CHAPTER 2 INSTALLATION JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 6 2-1 Best Conditions For Use When installing and wire connecting on JIF-2002, please follow the points and guide for preventing any abnormal situation occurred. Before connecting the Electric Power Supply, please identify the input Electric voltage type is AC 110V or AC 220V.
  • Page 7 To connect your load cell to the weighing Indicator use a six-wire cable with shield-connect the wires as indicated above. If the JIF-2002 is located near the Load Cells (Within five meters or a few yards) you may use a 4-wire cable with shield, but first connect screws 1&2 and 3&4 with...
  • Page 8 2-4 Front and Rear Panel Dimensions Front Panel Rear Panel Side View For Mounting JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 9 CHAPTER 3 SPECIFICATIONS JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 10 ZERO Temperature ±(0.2μV + 0.001% of Dead Load)/℃ Comp. SPAN Temperature ± 0.001% ℃ TYP Comp. Max. Resolution 1/16,000 (JIF-2002 Resolution can reach 1/60,000 depending on load cell quality & performance). 3-2 General ◎ General Type JIF-2002 AC 110V or AC 220V ±10%,...
  • Page 11 〝TARE CLEAR╱→〞Key Tare is cleared/Right shift Key 〝PRINT╱ACC〞Key Print data will send one time/Print Accumulation 〝ACC╱CLEAR〞Key Display Accumulator/Clear Accumulation 〝SET POINT╱CODE〞 Key Setting set point values/ Change set point code 〝Fn〞Key Unused 〝MODE╱↵〞Key Change Mode/Enter Key 〝STANDBY╱ESC Key Standby Status/Leave the current status JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 12 F C00 Data type 5Gross Weight, NET Weight, TARE Weight Stream 2 Stable and auto print 3Manual print F C01 Output Mode mode4Accumulate and print Sending without set point Code F C02 Output Format 1Sending with set point Code JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 13 Setting Year. Month, day, hour, minute, second F 300 Time F 301 Data Format Not print 2Only print above the latest data Date 3Print on all 1 Not print Only print above the latest data Time 3Print on all JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 14 F 504 0.0mA through 9.99mA (Initial 20.0 mA) at Full Capacity Output Volt when display -2.5V through +59.9V (Initial 00.0 V) F 505 ZERO Output Volt at -2.5V through +59.9V (Initial 10.0 V) F 506 Full Capacity JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 15 3-5 Panel Key Function Table Key Function Function Position Status Panel Key ZERO JIF-2002 returns to the Pin 25 + center of ZERO if the Control I / O ZERO (Pin 16 or 17) weight value within F004 OP-02 range.
  • Page 16 Left shift key Panel Key while setting Increase value Panel Key while setting Decrease value Panel Key while setting Panel Key “Enter” key while setting ※Please refer to chapter 6 on Control I/O and OP-02 JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 17 CHAPTER 4 SYSTEMFUNCTIONS JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 18 4-1 System Check A system check should be run: after initial installation, after moving your JIF-2002 connecting or disconnecting an attachment from the Rear Panel and as means of locating any unexplained system error. An occasional self-check to make sure everything is working properly is a good maintenance practice as well.
  • Page 19 ※When short-circuiting COM17.COM16 with pin13∼pin16 , the short-circuit pin will light up a specific LED on the front panel. If two or more LED light up or turned off at the same time, there suggests an error occurred. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 20 If you want to return to previous function category, please press ESC key, or press ↵ key to enter. If any errors occurred, please check if each setting value within effective range. note:● Indicates initial factory setting. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 21 Strong Good Slow F004 Set ZERO Range 5 ±5% of weighing platform Full Capacity ● 10 ±10% of weighing platform Full Capacity 20 ±20% of weighing platform Full Capacity 30 ±30% of weighing platform Full Capacity JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 22 1 SEC 3.5 DIV 1 SEC 4.0 DIV 2 SEC 0.5 DIV 2 SEC 1.0 DIV 2 SEC 1.5 DIV 2 SEC 2.0 DIV 2 SEC 2.5 DIV 2 SEC 3.0 DIV 2 SEC 3.5 DIV 2 SEC 4.0 DIV JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 23 5 GROSS Weight, NET Weight, TARE Weight FC01 Output Mode ● 1 Stream 2 Stable and auto print 3 Manual Print Mode 4 Accumulate and Print FC02 Output Format ● 0 Sending without set point Code 1 Sending with set point Code JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 24 Set between 0.0 to 2.0 Sec (● Initial 0.0 Sec) F103 Timer-Finish Signal The finish signal timer can be Set between 0.0 to 9.9 Sec ※● Initial 0.0 Sec ※Finish Signal sent ON at 0.0 Sec. And stays ON until the next START Signal JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 25 Panel key BCD Input Serial Input Automatic Free Fall Compensation F107 Please enter 6 digit free fall compensation value within effective range ● Initial “000.000”--- Free Fall OFF ◎SERIAL (RS-232) F200 Band Rate 1200BPS 2400BPS 4800BPS 9600BPS JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 26 3 Manual Print Mode 4 Accumulate and Print 5 Command Mode F204 Output Format ● 0 Sending without set point Code 1 Sending with set point Code ◎ Printer Setting Date, Time F300 YY / MM / DD HH:MM:SS JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 27 Weight Latest data “ t “ Print on all TARE according to Weight F001 GROSS Weight, Print on all “ g“ Weight, TARE Weight GROSS Weight, Print on all “ t “ Weight, TARE Weight Initial 1 JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 28 3 Manual Print Mode 4 Accumulate and Print Output Logic F402 Positive Logic Negative Logic ◎Analog Output F 500 Analog Output Data Output 4~20 mA Output 0~+10 V F 501 Output Mode Same as display GROSS Weight NET Weight JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 29 Turn the power switch ON. The screen will show blinking SELECT. STEP 3: Please press GROSS/NET key and a blinking CAL will show on the screen. Then press the ↵ key. The screen will show F-CAL. Please press the ↵ key. STEP 4: JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 30 Please press the ↵ key to finish the calibration. The screen will show ..STEP 5 : The screen will show END . Slide the SET switch to the original side. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 31 Point position. Press the ↵ key to set the decimal position. ﹝3﹞Setting Maximum Capacity When setting maximum capacity, the screen will show CAP →C000000.Use the key to move through digits. Use JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 32 Volt. Please press the ↵ key to finish d-SPAN. The screen will show ..STEP 5: The screen will show END . Slide the SET switch to the original side. ※Example of selecting FULL CALIBRATION (Div 2, 3 decimal, Max cap.20) JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 33 Disable unimportant or unused keys. STEP 1: Turn the Power Switch OFF on the rear panel. Slide the SET switch to the set side. STEP 2: Turn the power switch ON. The screen will show blinking SELECT. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 34 After enter ↵ key, a 〔 〕 will show on the screen. Please press the key you wish to disable. The screen will show the key’s number. JIF-2002 will inquire if you want to lock or unlock the key: 〔00〕 u or L (Key number 〔00〕 : Unlock or Lock the key).
  • Page 35 NO or YES . If NO is entered, the screen will show END. If YES is entered, the screen will show ……→ END . STEP 5 : Slide the SET switch to the original side for finishing the step. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 36 STANDBY key ( SET POINT/CODE key still holding). Please release the SET POINT/CODE key in sequence. Please press the ↵ key and the JIF-2002 will subsequently ask the operator to clear set point data. key to choose NO or YES and press the ↵ key to STEP 4: Use the confirm.
  • Page 37 Add an additional resistor (50kΩ∼500KΩ) between EXC+ and SIG—. ※ Refer to the Right Figure C.Err 3:The load cell output is too small at ZERO calibration. Add an additional resistor (50kΩ∼500KΩ) between EXC+ and SIG+. ※Refer to the Right Figure JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 38 C.Err 9: The maximum, capacity has been wrongly entered as a value smaller than 100. Check Resolution Table. C.Err10 :The maximum, capacity has been wrongly entered as a value greater than 750,000. Check the load cell specification or load cell failure. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 39 ------------ ------------ ------------ 1/12000 600,000 ------------ ------------ ------------ ------------ ------------ 1/14000 700,000 ------------ ------------ ------------ ------------ ------------ 1/15000 750,000 ------------ ------------ ------------ ------------ ------------ ☆JIF-2002 Display Resolution can reach 1/60,000. (Depends on load cell quality and performance). JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 40 :1 bit 4. Stop bit :ASCII 5. Output Code CURRENT LOOP 1 20 mA 0 0 mA Pin Assignment: Pin 1:Serial Output Pin 2:Frame Ground Pin 3:Serial Output **Output has no polarity , rather it is bi-directional. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 41 CHAPTER 5 SET POINTS JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 42 The screen will show Final. Please press the ↵ key, and the STEP 2: screen will show 6-digit value with blinking 0 000.000. Use the key to change position and key to change value. Please press the ↵ key to confirm FINAL value. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 43 STEP 8: The screen will show CODE 00, please press the STANDBY key to leave set point codes. If you wish to continue reset other SET POINT CODES. Please enter values according to step1 to step 8 again. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 44 ON. Closed the Full-Flow Gate by using the SP 1 Output ON signal. 4. When the display reaches "Final - SP 2", the SP 2 Output (Pin 11) signal will come ON. Closed the Medium-Flow Gate by using the SP 2 Output ON signal. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 45 9. When the GROSS weight is below the ZERO band, the ZERO Band Output will come ON -signifying the Weighing Hopper is empty. Closed the Weighing Hopper Discharge Gate by using the ZERO Band (Pin 13) Output ON signal. 10. You are now ready for your next batching event. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 46 6. Open the Full-Flow Gate and the Dribble-Flow Gate for Full-Flow filling into the Receiving Bin. 7. When the display reaches "Final - SP 2", the SP 2 Output (Pin 11) signal will come ON. Closed the Full-Flow Gate by using the SP 2 Output ON signal. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 47 11. If the GROSS weight of the Weighing Hopper is below the ZERO Band (Pin 13), the ZERO Band Output will be ON. The ZERO Band Output will refill Weighing Hopper if needed. 12. Ready for next batching event. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 48 OFF. Closed the Full-Flow Gate by using the SP 1 Output OFF signal. 6. When the display reaches "Final - SP 2", the SP 2 Output (Pin 11) signal will come OFF. Closed the Medium-Flow Gate by using the SP 2 Output OFF signal. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 49 14. If an Abort signal is sent (Pin 21) anytime after the Start signal is received, then: (1) SP 1, SP 2 and Free signals will go OFF, and Gates will be closed. (2) Batch Finish and Data Output signals will be sent. (3) NET Weight data will be accumulated. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 50 Start signal is received, the SP 2 and Free Outputs "come ON". Note : When the Final Weight is 0, the Pin 11 and 10 are kept OFF . 7. Open the Full-Flow Gate and the Dribble-Flow Gate for Full-Flow filling into the Receiving Bin. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 51 17. If an Abort signal is sent (Pin 21) anytime after the Start signal is received, then:(1) SP 1, SP 2 and Free signals will go OFF, and Gates will be closed. (2) Batch Finish and Data Output signals will be sent. (3) NET Weight data will be accumulated. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 52 ON. Closed the Full-Flow Gate by using the SP 1 Output ON signal. 5. When the display reaches "Final - SP 2", the SP 2 Output (Pin 11) signal will come ON. Closed the Medium-Flow Gate by using the SP 2 Output ON signal. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 53 Output will come ON which signifying the Weighing Hopper is empty. Closed the Weighing Hopper Discharge Gate by using the ZERO Band (Pin 13) Output ON signal. 13. You are now ready for your next batching event. JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 54 CHAPTER 6 OPTIONS JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 55: Pin

    Please enter six-digit Over Limit Value NET weight > Final + Over Limit Value LO Under Limit Please enter six-digit Under Limit Value NET weight < Final - Under Limit Value CODE INPUT Pin Name Pin Name 1×1 2×10 2×1 4×10 4×1 8×10 8×1 Common 1×10 JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 56: Input

    Output JIF-2002 ◎INPUT SCREW DESCRIPTION Screw Signal Name Description JIF-2002 returns to the center of ZERO when the weighing device is Pin 25 ZERO Input (Pulse input) empty JIF-2002 switches to TARE mode, ZERO's the display and stores the Pin 24 TARE Input (Pulse input) TARE weight in memory.
  • Page 57: Table Of Contents

    Pin 21 2Customer Program- 2When Pin 21 is short-circuit to control Mode Automatic COM1, JIF-2002 will estimate the free Free Fall Compensation fall value for the next batch, and the command (Pulse input). NET weight will be accumulated.
  • Page 58: Pin 9

    Weight, TARE Weight Stream 2 Stable and auto print 3 Manual Print Mode 4 Accumulate and Print F 203 Output Mode 5 Command Mode Sending without Set point Code 1 Sending F 204 Output Format with set point Code JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 59 Type EIA-RS-232C 12V Transmission Half Duplex, Asynchronus Transmission 1200BPS、2400BPS、4800BPS、9600BPS Baud Rate 8 bit non- parity 7 bit even parity, odd parity Parity Stop Bit 1 bit Output Code ASC II ◆ I/O Specifications 25 Pin D- Shape JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 60 Min. Capacity STABLE UNSTABLE ※HEADER 2 GROSS TARE ※UNIT Kilogram Pound ASCII data characters “ 0 ” ~ “ 9 ” “ ” Space(20H) “ • ” Decimal Point(2EH) “ - ” Minus(2DH) “ + ” Plus(2BH) JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 61 G Cr Lf will be sent by JIF-2002. 〈GROSS〉 ※If an invalid character is received?Cr Lf will be sent by the JIF-2002 ※If the commands are not accepted for any reason:I Cr Lf will be sent by the JIF-2002 Sending Command to...
  • Page 62 Unit 4Print on all according to F001 5Print on all “g” 6Print on all “t” 1Stable and auto print Manual Print Mode F 302 Output Mode 3Accumulate and Print MINI Printer 2Normal Printer F 303 Select Printer JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 63 Same as display 2 Gross data 3 NET data Data type F 400 4 TARE data Stream 2 Stable and print 3 Manual print F 401 Output Mode mode4 Accumulate and print Positive Logic 2 Negative Logic F 402 Output Logic JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 64 4×10 2×1000 〞 8×10 4×1000 Lo=Negative Polarity 8×1000 1×10000 / Decimal Point 1 2×10000 / Decimal Point 2 4×10000 / Decimal Point 3 8×10000 / Decimal Point 4 Hi=Overload 1×100000 2×100000 4×100000 PRN 1 / Busy(input) 8×100000 JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 65 Same as display 2Gross data F 501 Output Mode 3NET data Loss-in-weight Not read Absolute Value F 502 1 JIF-2002 reads Absolute Value Absolute Value Output current F 503 0.0mA through 9.99mA (Initial 0.40mA) when display ZERO Output current at F 504 0.0mA through 9.99mA (Initial 20.0mA)
  • Page 66 More than 1 / 1000 ±(0.015 % / ℃ of rdg + 0.01mA) /℃ Temperature Coefficient 5 KΩ Minimum Minimum If you add a 10 KΩ resistor , the output will be 0mA to 1mA (0~10 V) JIF-2002 WEIGHING INDICATOR&CONTROLLER...
  • Page 67 Setting Output Voltage + (weight / capacity ) * ( V (if 0<= V <=10 V) : Output Voltage : Output at ZERO (F505) : Output at Maximum Capacity (F506) NOTE: The Maximum Output will be saturated at 11.25. JIF-2002 WEIGHING INDICATOR&CONTROLLER...