Download Print this page

LK Systems Wallbox UNI Push AX16 V2 Assembly Instructions Manual page 2

Advertisement

LK Wallbox UNI Push AX
1.1. Check that all the parts on the wallbox are
whole prior to assembly. If any part is damaged,
it must be replaced.
1.2. Drill a hole of diameter 54 mm.
The wallbox can be fastened in many different
ways:
When two wall boxes are to be installed on a
wooden stud, LK Wallbox UNI Push Clamp
(Article no. 188 11 04) can be used.
2 (8)
Assembly instructions | LK Wallbox UNI Push AX16 V2 and AX20
1.3. There are two different ways to mount the wall-
box on, select 1.3.1 or 1.3.2. Always try to assemble
the wallbox so that the shank is as short as possible,
this facilitates any replacement of the pipe.
1.3.1 Fasten the wallbox with the supplied screws.
The wallbox should always be attached against the
nogging piece, stud or Wet-Room-Wall 2012 (Safe
Water-wall). When assembling from the front or
the back, use the four shorter screws. When assem-
bling at the side of a stud or upwards against a
nogging piece, use the two longer screws. Proceed
to step 1.4.
1.3.2 Start by mounting LK Universal Pipe
according to step 1.4 and follow the installa-
tion instructions to step 1.10. Assemble the
wallbox from the front or back with the four
shorter screws. When assembling at the side
of a stud or upwards against a nogging piece,
use the two longer screws. The wallbox should
always be attached against the nogging piece, stud
or Wet-Room-Wall 2012 (Safe Waterwall). Then
follow the instructions from point 1.11.
NOTE!
The wallbox may never be attached only in
plaster.
1.4. Adjust the length of LK Universal Pipe by
cutting it perpendicular with a pipe cutter. Cut
the conduit another 30 mm for the 16 mm wall box
and about 40 mm for the 20 mm wall box than the
media tube is.
1.5. For both LK PE-X and LK PAL Universal Pipes
must ben deburred inside to prevent damage or
displacement of the O-rings, which will inevitably
result in a leaking joint. After deburring, the pipes
must be cleaned from any shavings.
EN.29.C.46.20200318