Table of Contents: Joule Solar Hot Water Systems Solar Controller Wiring Diagram Panel Types How Your Solar System Works Troubleshooting What Maintenance Is Required Maintenance Sheet SOLAR SYSTEMS manual and maintenance...
Joule Solar Hot Water Systems All our systems are designed to be fully automatic in operation, require no intervention by you and are designed to provide many years of trouble free operation. However, please take a moment to read these notes in conjunction with our commissioning...
DeltaSol DeltaSol BS/4 BS/4 ® ® Sensors S3 and S4 can optionally be connected for mea- The controller calculates the temperature difference between collector sensor S1 and store sensor S2. If the surement purposes. S3 can optionally be used as reference sensor for the store emergency shutdown option (OSEM).
The type of control system installed in your property depends on the panel type sup- plied with your system. The solar system installed in your home features either the Joule Navitas on-roof or in-roof solar panels, Joule VisSolis in-roof solar panels or Joule Acapella high efficiency vacuum tube solar panels.
How Your Solar System Works The Joule solar system installed is designed to heat your hot water cylinder using energy from daylight and air temperature. The solar system works by taking the heated fluid in the solar collector and pumping it through the pipe work into the coil in your hot water cylinder.
Page 8
How Your Solar System Works The solar system is not designed to supplement your heating system. (unless expressly designed with that purpose but as standard it is to heat hot water only). The solar system will only circulate hot water from the collector on the roof to your hot water cylinder when the roof fluid temperature is 7°C warmer than the water in your hot water cylinder.
Page 9
What happens when you go on holidays When you go on holidays or leave your house for more than a couple of days then you are not using any hot water out of your hot water cylinder. This means that the solar system heats your cylinder on day 1 and then on day 2 it has no water left to heat because the cylinder was heated the previous day and no water has been taken out of the hot water cylinder.
Troubleshooting DeltaSol BS/4 ® 5. Troubleshooting fuse In the case of an error, a message is shown on the display of the controller: DE-45527 Hattingen DeltaSol BS/4 V2 100 ... 240 V~ 50-60 Hz Made in Germany CU 72091163 01 IP 20 1 (1) A 100 ...
Page 11
DeltaSol BS/4 ® 5.1 Various Pump is overheated, but no heat transfer from the Pump starts for a short moment, switches off, switches collector to the store, flow and return have the same on again, etc. temperature; perhaps also air / gas bubbles in the lines. Air in the system? Temperature difference Air in the system;...
Page 12
DeltaSol BS/4 ® Stores cool down at night Control the non-return Further pumps which are valve in warm water cir- connected to the solar culation - o.k. store must also be che- cked. Collector circuit pump runs during the night? Check controller: Manual operation active? Clean or replace it...
If you notice an issue with your solar system call your installer and ask them to have a look at the system. If the issue is a product warranty issue your installer will contact Joule to arrange for the issue to be resolved. SOLAR SYSTEMS...
Need help?
Do you have a question about the Acapella and is the answer not in the manual?