Mitsubishi Electric PLFY Series Technical & Service Manual page 10

Ceiling cassettes
Hide thumbs Also See for PLFY Series:
Table of Contents

Advertisement

Main menu list
Setting and display items
Vane · Louver · Vent.
(Lossnay)
High power
Timer
On/Off timer* Use to set the operation On/Off times.
Auto-Off
timer
Weekly timer*
Restriction
Temp. range
Operation
lock
Energy
Auto return
saving
Schedule*
Night setback*
Filter information
Error information
Maintenance Manual
vane angle
Initial setting Clock
Main display Use to switch between "Full" and "Basic" modes for the Main display.
Contrast
Language
selection
* Clock setting is required.
OCH569
Use to set the vane angle.
• Select a desired vane setting from five different settings.
Use to turn ON / OFF the louver.
• Select a desired setting from "ON" and "OFF."
Use to set the amount of ventilation.
• Select a desired setting from "Off," "Low," and "High."
Use to reach the comfortable room temperature quickly.
• Units can be operated in the High-power mode for up to 30 minutes.
• Time can be set in 5-minute increments.
Use to set the Auto-Off time.
• Time can be set to a value from 30 to 240 in 10-minute increments.
Use to set the weekly operation On / Off times.
• Up to eight operation patterns can be set for each day.
(Not valid when the On/Off timer is enabled.)
Use to restrict the preset temperature range.
• Different temperature ranges can be set for different operation modes.
Use to lock selected functions.
• The locked functions cannot be operated.
Use to get the units to operate at the preset temperature after performing energy-save
operation for a specified time period.
• Time can be set to a value from 30 and 120 in 10-minute increments.
(This function will not be valid when the preset temperature ranges are restricted.)
Set the start/stop times to operate the units in the energy-save mode for each day of the
week, and set the energy-saving rate.
• Up to four energy-save operation patterns can be set for each day.
• Time can be set in 5-minute increments.
• Energy-saving rate can be set to a value from 0% or 50 to 90% in 10% increments.
Use to make Night setback settings.
• Select "Yes" to enable the setting, and "No" to disable the setting. The temperature range and
the start/stop times can be set.
Use to check the filter status.
• The filter sign can be reset.
Use to check error information when an error occurs.
• Check code, error source, refrigerant address, unit model, manufacturing number, contact
information (dealer's phone number) can be displayed.
(The unit model, manufacturing number, and contact information need to be registered in
advance to be displayed.)
Use to set the vane angle for each vane to a fixed position.
Use to set the current time.
• The initial setting is "Full."
Use to adjust screen contrast.
Use to select the desired language.
Setting details
Continue to the next page