[SELF DIAGNOSTIC SCREEN DISPLAY]
Format of error timestamps
YYMMDDhhmmss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error timestamp
is saved.
Both of HDMI_EQ/TU_DEMOD have been disabled.
(Refer the previous page for details.)
•Panel Operation Time is recorded every
30 min, but Total Operation Time is recorded every 1 hr.
Therefore, the panel op. time might become larger than
the total op. time.
Total Operation Time [hr] – Boot Count – Panel Operation Time [hr]
KD-49/55X8005C,XBR-55/65X800C,805C,807C,809C,810C
Error item Naming
Back
002
003
003
003
003
004
004
005
005
Smart Core Red LED
006
blinking count
007
007
008
00005
SELF CHECK
MAIN_POWER
000000000000
DC_ALERT
000000000000
AUD_ERR
150101000018
HDMI_EQ
150101000123
TU_DEMOD
150101000218
LD_ERR
000000000000
BCM_ERR
000000000000
TCON_ERR
150101000504
P_ID_ERR
000000000000
BACKLIGHT ERR
000000000000
TEMP_ERR
150101000200
4KBE_ERR
000000000000
SW_ERR
000000000000
00414
00002
Error
timestamp for
last recorded
error
SELF DIAGNOSIS FUNCTION
000000000000
000000000000
000000000000
000000000000
150101000018
150101000018
150101000045
150101000045
150101000223
150101000105
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
150101000002
000000000000
000000000000
000000000000
000000000000
000000000000
[Home]Exit
Error
Error
timestamp for
timestamp
second last
for 3rd last
recorded error
recorded
error
Error count
<<
000
000
003
003
003
000
000
001
000
000
002
000
000
10