Whenever BellaGlide is turned on; its energy level will automatically be reset to the lowest energy level.
Only one Energy Level indicator Light will be on.
To set the energy level, press the central Button repeatedly to increase the energy level. After reaching level
5, an additional press will bring the level back down to Level 1. The number of Energy Level indicator Lights
will coincide with the change in energy level.
4. Apply the TREATMENT SURFACE to the skin, making sure the skin is spread evenly and smoothly and
the TREATMENT SURFACE is in full contact with the skin. Make sure the Ready Indicator Light starts
blinking slowly.
5. Press the Pulse Trigger. The device will first determine the color of your skin.
If the color of the skin is light enough for safe application, the device will flash a pulse of light onto your
skin. You will see a bright flash of light and simultaneously hear a subtle pop sound, which is a normal
noise for the device. You may feel a mild sensation of warmth and tingling.
BellaGlide will immediately recharge for the next pulse. After a few seconds (depending on the set
energy level) the Ready Indicator Light will turn on again and start blinking.
If you see no light pulse, and the Ready Indicator Light blinks rapidly, this is now the SKIN COLOR
WARNING INDICATOR LIGHT alerting that your skin tone is too dark for safe application. Try using
the device on a different body part or contact Silk'n support.
6. Move the TREATMENT SURFACE to another area of skin.
Administer one pulse at a time at your chosen energy level. Use the pressure marks the device just made in
your skin to guide you for proper positioning of the next pulse, avoiding both gaps and overlaps between pulses.
BellaGlide can be applied in two ways: "Pulsing" and "Gliding".
PULSING
When Pulsing, administer one pulse at a time at your chosen energy level. Use
the pressure marks the device just made in your skin to guide you for proper
positioning of the next pulse, avoiding both gaps and overlaps between pulses.
Covering skin areas
Treatments should be administered in rows, starting at one end of each row and
progressing sequentially towards the other end. This technique allows better
control of skin coverage, and helps you avoid treating the same area more than
once or overlapping skin areas. Ideal body areas for BellaGlide use include the
underarms, bikini line, arms and legs and below the cheekbones.
7. Repeat the process starting again with Step 5.
Try to avoid overlapping pulses!
Do not treat the same area of skin more than once per hair removal session!