Cres Cor H137WSUA5DMFBC Operating And Maintenance Instructions Manual

Humidity holding hot cabinet

Advertisement

Quick Links

5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE'S PROGRAMMING REVISION J-08

ELECTRICAL SPECIFICATIONS:

Model No.
H137WSUA5DMFBC
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Volts
Watts
120
2000

HOW TO INSTALL UNIT:

1. Place cabinet on level floor, in a well ventilated area.
2. Unpack and install inner pan slides parts.
3. Plug cord end into proper wall outlet.
HOW TO CHANGE FROM °C TO °F (if needed)
1. Push the switch on; the light will come on.
2. Push and hold the "SET" button and the button in
the lower left hand corner together for 5 seconds.
You are now entered into the menu.
3. Scroll over the"Unit" and change it to "C" , then
scroll to the "END".
WARNING
Air is VERY HOT when door is opened.

FIRST TIME OPERATION:

NOTE: A new cabinet needs to "burn off"
manufacturing oils and excess adhesive
before its first use. Do NOT load food into
cabinet until this has been done!
1. Push the switch on; the light will come on.
NOTE: The letters "LOTPR" (Low Temperature)
will show on the control panel until it
reaches 80°F (26°C).
2. Push and hold knob for 5 seconds, then turn to
show 220°F. Push the knob to set the temperature.
Run the unit for one (1) hour.
3. Push the switch off the unit off and let cool.
4. Wipe the inside clean with detergent and hot water.
Insulated
Hot Cabinets
Rev. 2 (12/20)
Amps
Hertz
Phase
16.7
60
1
FL-2355-BC
Page 1 of 8
NEMA
5-20P

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H137WSUA5DMFBC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cres Cor H137WSUA5DMFBC

  • Page 1 220°F. Push the knob to set the temperature. Run the unit for one (1) hour. 3. Push the switch off the unit off and let cool. 4. Wipe the inside clean with detergent and hot water. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 2 NOTE: This cabinet operates with air temperature priority. Humidity will only start after cabinet is fully preheated. If cold or room temp water is used, humidity build-up time will be longer. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 3 (Stainless Steel) HARD WATER SPOTS 1. Swab or wipe with cloth. Vinegar and SCALE 2. Rinse and dry. *Mild detergents include soaps and non-abrasive cleaners. NOTE: Gaskets are removable for cleaning. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 4 NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures . Replacement of electrical components must be done by a qualified electrician. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 5 4a. Low water 4b. Air temperature set too high. 4c, Defective heater, relay or control. Controller (Thermostats) Error codes: err 00 - Temperature probe defective err 01 - Water fill time out Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 6 Door Handle 0911-111 Handle, Side Pull 0911-087 Casters, 5” 0569-306-K Casters, 5” w/brake 0569-306-BK Wire Angles (Stainless Steel) 0621-281-SS-K Pan Rack Insert Each (for -1834 Model) 1103-109 Clear Drip Pan 1017-058 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 7 5925 Heisley Road • Mentor, OH 44060-1833 OPERATING and MAINTENANCE INSTRUCTIONS Model: H137 series Humidity Holding Hot Cabinet BUC-EE’S PROGRAMMING REVISION J-08 WIRING DIAGRAM: L1 T1 A2(-) A1(+) L1 T1 A2(-) A1(+) Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 8 5925 Heisley Road • Mentor, OH 44060-1833 OPERATING and MAINTENANCE INSTRUCTIONS Model: H137 series Humidity Holding Hot Cabinet BUC-EE’S PROGRAMMING REVISION J-08 WIRING DIAGRAM: L1 T1 A2(-) A1(+) L1 T1 A2(-) A1(+) Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...