Kenwood KDC-MP333V Service Manual page 11

Hide thumbs Also See for KDC-MP333V:
Table of Contents

Advertisement

Special displays while all lights are on
When all lights are on with STANDBY source, if the following
keys are pressed, the following messages are displayed.
[1] key
Version is displayed (forwarding)
(Display) TYPE : x_ _ _ ("x" is displayed in hexadecimals)
→ 650M – 2.02 ("development ID" – "version")
→ all lights on →
∗ TYPE indicates µ-com destination, and shows real-time
condition of the destination terminal.
[3] key
Key pressed: Power ON time is displayed.
While Power ON time is displayed, press the key for more
than 2 seconds to clear the Power ON time.
(Display)
PON_0Hxx (00~50 is displayed for "xx". When less
than 1 hour, display by increment of 10
minutes.)
xxxxx (00001~10922 is displayed for "xxxxx")
[4] key
Key pressed: CD operation time is displayed.
While the CD operation time is displayed, press the key
for more than 2 seconds to clear CD operation time.
(Display)
CDT_0Hxx (00~50 is displayed for "xx". When less
than 1 hour, display by increment of 10
minutes.)
xxxxx (00001~10922 is displayed for "xxxxx")
[5] key
Key pressed: Number of CD EJECT time is displayed.
While the CD EJECT times is displayed, press the key for
more than 2 seconds to clear the number of CD EJECT
times.
(Display) EJCxxxxx
[6] key
Key pressed: Number of times PANEL is opened/closed
is displayed.
While the PANEL open/close count is displayed, press the
key for more than 2 seconds to clear the PANEL open/
close count.
(Display) PC_xxxxx
TEST MODE
[FM]
key
[AM]
key
[
key
[
key
MAX 10922 (hours)
[
key
CD information display mode
MAX 10922 (hours)
[AM]
key
MAX 65535 (times)
MAX 65535 (times)
KDC-MP333V/MP333VS
ROM correction version is displayed
(Display) _ _ _RD123
ROM_ERR_ (When E2PROM is not installed)
_ _ _R – – – – (When not written in)
_ _ _R ∗ ∗ ∗ ∗ (When data not matching)
IC10 adjustment status
"E2P_OK": Adjustment completed
"E2P_ER" : E2PROM values are still default (not determined)
"I2C_ER" : Cannot communication with IC10/E2PROM
∗ If "E2P_OK", Pin 41 (TUN FANC OUT) should be
output as "H".
]
AUDIO data initialization
(Display) AUD_INIT
]
Key pressed: Forced Power OFF data displayed.
While the forced power OFF data is displayed, press the
key for more than 2 seconds to clear the data.
(Display) POFF_ – – – (No Forced Power OFF)
PNL (Forced Power OFF because of
system µ-com and panel communication error)
]
Key pressed: CD information display mode ON/OFF
While in CD information display mode, press the key for
more than 2 seconds to clear all CD information.
∗ Please refer to the next table.
I2C communication condition display
(Display) I2C_OK_ _
NG
CD mechanism error log display
(switched by [
] / [
] keys)
(Display) MCERR1: x x ↔ MCERR2: x x ↔
MCERR3: x x ↔ MCERR1: x x ↔
("– –" or the error code is displayed for "xx")
CD loading error log display (switched by [
(Display) LDERR1: x x ↔ LDERR2: x x ↔
LDERR1: x x ↔
(Number of times is displayed for "xx")
] / [
] keys)
MAX 99 (times)
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdc-mp333vs

Table of Contents