Menu Structure; Main Menu - Daikin EWWQ-G Operation Manual

Air and water cooled scroll chillers & heat pump
Table of Contents

Advertisement

EWWQ090G ÷ EWWQ720L - R410A - Water-cooled scroll chillers
EWLQ090G ÷ EWLQ720L - R410A - Condenser less
EWHQ100G ÷ EWHQ400G - R410A - Heat pump scroll chillers
EWAQ-G 075
- R410A - Air-cooled scroll chillers
EWAQ-
- R410A - Air-cooled scroll chillers
EWYQ-
- R410A - Air-cooled scroll heat pumps

4 Menu Structure

All settings are divided in different menus. Each menu collects in a single page other sub-menus,
settings or data related to a specific function (for example Power Conservation or Setup) or entity
(for example Unit or Circuit). In any of the following pages a grey box will indicate changeable
values and the defaults.

4.1 Main Menu

Setpoint/Sub-Menu
Enter Password
View/Set Unit
View/Set Circuit
Unit Status=
Off: Unit Loc/Rem Sw
Active Setpt=
Evap LWT=
Cond LWT=
Unit Capacity=
Chiller Enable=
Unit Mode=
Timers
Alarms
Commission Unit
Save and Restore
About Chiller
Operation Manual
28
Air and Water cooled scroll chillers & heat pump
Default
-
-
-
Auto
Off:
Ice Mode Tmr
Off:
All Cir Disabled
Off:
Unit Alarm
Off:
Keypad Disable
Off:
BAS Disable
Off:
Unit Loc/Rem Sw
Off:
Test Mode
Auto:
Wait For Load
Auto:
Evap Recirc (A/C only)
Auto
Water Recirc (W/C only)
Auto:
Wait For Flow
Auto:
Pumpdn
Auto:
Max Pull Limited
Auto:
Unit Cap Limit
Off:
Cfg Chg, Rst Ctrlr
7.0°C 
-
-273.1°C 
-
-273.1°C
-
0.0%
-
Enable
Enable-Disable
Cool
-
-
-
-
-
Range
Submenu to activate access levels
Submenu for unit data and settings
Submenu for circuit data and settings
Status of the Unit
Active setpoint and link to the
Setpoint page (see section 4.3.1.5 for
more details).
Evaporator
temperature
Temperatures page (see section 4.5
for more details).
Condenser
temperature
Temperatures page (W/C only).
Actual unit capacity.
Chiller
setting.
Actual unit mode and link to unit
available mode selection page (see
section 4.6 for more details).
Submenu
thermoregulation safety timers (see
section 4.7 for more details).
Submenu for alarms; same function
as Bell Button (see section 0 for more
details)
Submenu for the chiller configuration
(see section 0 for more details).
Submenu to the Save and Restore
page (see section
Application
section 0 for more details).
EWWQ - EWLQ - EWHQ
EWAQ - EWYQ
Air or Water cooled scroll chiller &
heat pump
D-EOMHW00107-15EN
Operation
Manual
Description
leaving
water
and
link
to
the
leaving
water
and
link
to
the
operation
enable/disable
compressors
and
Info
submenu
(see

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewlq-gEwhq-gEwaq-gEwyq-g

Table of Contents