Advertisement

Quick Links

NO.10 Yanshan Road, Beilun,
Ningbo, Zhejiang, China.
www.refineindustry.com
sales@refineindustry.com
support@refineindustry.com
Refine Wh100
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Wh100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Refine Wh100

  • Page 1 NO.10 Yanshan Road, Beilun, Ningbo, Zhejiang, China. www.refineindustry.com sales@refineindustry.com support@refineindustry.com Refine Wh100 USER MANUAL...
  • Page 2 Specifications How it Works Installation Requirements Installation Electrical Requirements Water (Condensate) Removal Ducted Applications Unita Diagram Maintenance Dehumidifier Storage Troubleshooting Remote Control Instructions Spare Parts...
  • Page 3 Specifications Installation Location Capacity@80℉/60%RH: 120PintsPerDay Airflow @ 0.0” SP: 300CFM The good thing with this device is that its location is versatile. It can be installed in a Operating Temp. Range: 33-105°F variety of areas to ensure that the installer meets the client’s needs. But still, the following aspects should be considered: Operating Relative Humidity Range: 36%-90% COP: 2.8 L/kWh...
  • Page 4 Electrical Requirements Duct Adapter Installation • Screw in the 4 screws on each duct Normally, the CoAiro dehumidifier plugs into one major grounded outlet on a relatively 110 to adapter. 120 VAC 15 Amp circuit. In some cases the use of the GFCI (Ground Fault Circuit Interrupter) is advisable.
  • Page 5 Maintenance Troubleshooting **For more detailed instructions, visit www.unipdry.com** WARNING: Always unplug the unit before doing any maintenance. Symptom Cause Solution Cleaning the Machine Body Verify that both ends of the • Use a soft, damp cloth to clean the exterior of unit. Do not use any Poor Connection cord are plugged in soap or solvents...
  • Page 6 2.Up Button/ Down Button 4. Water Drainage Use the up and down arrows to • The Rfeine Wh100 has an integrated condensate pump.During normal operation, the adjust the humidity level. Rfeine Wh100 will automatically drain as required. • If you would like to store or move your unit, press the drain button to drain water from the 3.Mode...
  • Page 7 Spare Parts Display/Control Fan Components N-1210 Fan Motor N-100 Main Control Board N-1211 Complete Fan Assembly N-101 Display Board N-1205 Fan Capacitor N-102 RH/Temp. Sensor Filter + External Components Inernal Components N-1200 Prefilter N-1209 Compressor N-1201 MERV 8 N-1206 Compressor Capacitor N-1202 HEPA N-1208...

Table of Contents