contents 一.Familiar with the machine ......................错误!未定义书签。 二.Button part ..........................错误!未定义书签。 三.LCD icon display .......................... 错误!未定义书签。 四.Menu information ........................错误!未定义书签。 五.Introduction to common operations ..................错误!未定义书签。 1. Dual stage single / double guard switch ....................... 9 2. Frequency / channel mode switching ..................错误!未定义书签。 3.
Page 3
一. Familiar with the machine Waiting to add appearance and description 二. Button part PTT button (transmit button) The transfer button for transmitting and receiving, press this button when transmitting, and speak to the microphone; when receiving, release this button Side button 1 A.
C. SMS editing interface, move down Left shift key:P1 A. Move to the left. B. Under DTMF function, it means C code word (without any word code) C. SMS editing interface, move left Right shift key:P2 A. Move right. B.
Page 5
Current transmit power is high (H) or low (L) digital non-dual capacity direct mode Digital mode, dual capacity direct mode is on and works in time slot 1 Digital mode, dual capacity direct mode is on and works in time slot 2 CTDCS Analog and no CT/DCS setting Analog and CT setting...
Page 6
四. Menu info Press OK to enter the menu; press up, down, left, and right to select, press OK to confirm; press EXIT to return First level Second level Third level Option Setting description Remarks menu menu menu view contact Check contact name and number Contact The contact configuration number is 0-9, and...
Page 7
mode Delete all Yes: clear dialed call list, No: Do not delete Received private call,press OK to view/add Answered List… contact/delete, add to contact to enter Answered alias to store in contact list Yes: clear received call list, No: Do not Delete all delete Missed private call,press OK to view/add...
Page 8
There is a warning 10 seconds before transmission limit time. limit is reached, and it is time to prohibit transmitting. For 15~495S example, set 60 seconds and issue a warning for 10 seconds at the 50th second. If you continue to trasnmit, the transmit is prohibited at 60 seconds turn off VOX Do n’t press PTT when you turn it on, you...
Page 9
Both:Enable this tone for both digital and analog channels Options: off / on. No beep sound when the Key Beep close button is selected Always On Always On Backlight Always Off Always Off 5/10sec Time to automatically turn off the backlight Long press * to lock, then press OK and * Key Manual unlock...
Digital processing chip DSP software version DSP-version number Program Date Program last programmed date and time of radio Time Receiving frequency settings, press * to clear them all, press BACK Rx_Freq to delete them individually Transmission frequency setting, press * to clear all, press BACK to TX_Freq delete them individually Channel name settings, press * to clear all, press BACK to delete...
Note: Since the double wait mode is in the primary and secondary channel scanning by turns, the DTMF signaling system and auto scan do not work. 2. VFO / MR mode switch In the main interface, press P2 to switch between VFO mode and MR mode. There is no channel number display in VFO mode.
number input box and enter the other party's number) . Press PTT to initiate private call. The interface displays: the first line displays the call type: private call, the second line displays the contact alias, and the third line displays the private call number.
Initiate: In the digital mode, select private call contact (press OK to enter menu, select private call contact or main interface press # key to enter private call number), select “radio check”, press OK button to start, display “radio check success”when success, displays "radio check fail" when failed.After radio is successfully checked, you can call the other party by PTT.
codeword is a remote code or wake-up code. 6.2 PTTID Initiation: In analog mode, you can configure the DTMF online and offline codes through the host computer. The analog channel enables the online and offline codes. Each time the PTT is pressed, the online code is issued. 7.Sacn 7.1 switch 1:The upper computer configures the current channel to enable automatic scanning, switch to this channel for...
Page 15
This radio is NOT intended for use by the“General Population” in an uncontrolled environment. This radio has been tested and complies with the FCC RF exposure limits for“Occupational Use Only”.Inaddition, our TYT Electronics Co., Ltd. radio complies with the following Standards and Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for exposure to humans: ---IEEE Std.
Page 16
distance of 2.5cm must be maintained when held-to-face, and body-worn operations are restricted to the approve doriginal acessories. Cet EUT est conforme aux normes SAR pour les limites d’exposition contrôlée de la norme IC RSS-102 et a été testé conformément aux méthodes et procédures de mesure spécifiées dans les normes IEEE 1528 et IEC 62209.
Need help?
Do you have a question about the MD-750 and is the answer not in the manual?
Questions and answers