5.4 Motors

[A] Tray-up motor unit
(1) Remove the rear cover.
(2) Remove the harness from the 2 clamps.
(3) Disconnect 3 connectors.
(4) Remove 5 screws and take off the tray-up
motor unit.
Note: Tray-up motor unit is connected with the
copier with other harness. Do not disconnect
them and place the unit nearby the copier.
[B] PFP motor unit
(1) Disconnect 2 connectors.
(2) Remove 2 screws and take off the PFP motor.
(3) Remove one screw and take off the lever shaft
bracket.
(4) Remove 4 screws and take off the PFP motor
unit bracket.
Note: The positions to attach the
shift lever bracket and lever
shaft bracket differ according
to each model.
(5) Remove the clip and pull out the lever shaft.
(6) Take off the shift lever bracket. Remove the gears
and belt from the PFP motor unit bracket.
October 2000 © TOSHIBA TEC
Connector
Tray-up
motor unit
Lever shaft
bracket
DP4500/3500
(Lever position: HIGH)
Gears
5 - 3
Connector
(4) (4)
(3)
(2)
(4)
(4)
DP1600/2500
(Lever position: LOW)
Shift lever blacket
Clip
Lever shaft
KD-1009 DISASSEMBLY
Connector
Clamps
Connectors
Gear
Belt