Summary of Contents for CIAT DESTRATIFIER TPL 4000

  • Page 1 EN7512234-03 06 - 2019 I n s t r u c t i o n m a n u a l...
  • Page 2 H4000 HELIOTHERME EN-2...
  • Page 3: Table Of Contents

    CONTENTS 1 - RECEIPT OF THE UNIT ................................4 2 - HANDLING ....................................4 3 - TECHNICAL CHARACTERISTICS ............................5 3.1 - ROTOREX fan motor assembly ............................5 3.2 - CORROBLOC fan motor assembly ............................. 5 3.3 - HEE fan motor assembly (EC motor) ..........................6 4 - HEAT EXCHANGER ................................
  • Page 4: Receipt Of The Unit

    Thank you for purchasing a 4000 series HELIOTHERME or TPL. We hope that you will be completely satisfied with this CIAT air heater or destratifier unit. To ensure correct operation, all connections (electrical, hydraulic, etc.) must be made in accordance with industry practice and the regulations in force in the country of use. Your unit must be maintained as recommended in this manual.
  • Page 5: Technical Characteristics

    3 - TECHNICAL CHARACTERISTICS 3.1 - ROTOREX fan motor assembly 1 Ph/230 V AC motor Rotation Nom. Abs. Thermal cut- Model Motor Class Operating temp. speed current pressure H4350 1330 rpm 0.70 A 150W -40°C / +60°C SINGLE- H4400 / TPL4400 1400 rpm 1.30 A 300W...
  • Page 6: Hee Fan Motor Assembly (Ec Motor)

    3 - TECHNICAL CHARACTERISTICS 3.3 - HEE fan motor assembly (EC motor) Single-phase motor NOM. P. (W) Operating Model Motor ROTATION SPEED Protection CLASS I (A) temp. H4300 1500 rpm 0,80 TACH -25 °C/+55 °C H4350 1480 rpm 1,35 TACH -25 °C/+50 °C H4400 / TPL4400 1760 rpm...
  • Page 7: Heat Exchanger

    4 - HEAT EXCHANGER 4.1 - Low Pressure Water Coil Copper tube Aluminium honeycomb fins LP water coil H4300 H4350 H4400 H4450 H4500 H4630 H4630S Number of heating rows Number of cooling rows Coil capacity 0,68 1,18 1,66 0,96 1,59 2,28 1,38 2,27 3,22 2,18...
  • Page 8: Dimensions

    5 - DIMENSIONS 5.1 - H4000 Heliotherme Size H4300 H4350 H4400 H4450 H4500 H4630 H4630S 1050 1050 1 row Weight 2 rows (kg) 3 rows E* = HEE FMA 5.2 - TPL4000 Destratifier Size TPL40 TPL45 TPL50 TPL63 Weight E* = HEE FMA H4000 HELIOTHERME EN-8...
  • Page 9: Setup

    6 - SETUP 6.1 - H4000 Heliotherme Min: 0.15 m To ensure correct air diffusion and to comply with the EN 294  standard relating to safety zones, you are recommended to position HELIOTHERME units at a height of: - Between 2.5 and 4.5 metres when wall-mounted - Between 4.5 and 10 metres when ceiling-mounted. If the fan motor assembly is removed, also ensure that the rear of the unit is a sufficient distance from the wall to allow access: 6.2 - TPL4000 Destratifier...
  • Page 10: Ceiling-Mounted H4000 Heliotherme

    6 - SETUP Installation with wall-mounting kit + additional kit on IPN Wall-mounting kit Assembly procedure: Support tube H M8 x 50 screw Pre-assemble the clamping plates on the brackets using + serrated washer the Ø 8 mm serrated washers and the H M8 nuts (not tightened).
  • Page 11: Water Connections

    This is not covered by the CIAT warranty 7.2 - Connection to be welded (Heliotherme HP fluid) Ensure that the casing and the rubber caps are protected from the excessive heat produced during welding by using a damp cloth when welding between the HELIOTHERME and the supply pipes.
  • Page 12: Electrical Connections

    Before connecting the unit to the mains, ensure that the voltage matches that given on the unit's name plate (230 V - 50 Hz for single-phase and 400 V - 50 Hz for three-phase). The unit must be connected to earth. CIAT shall not be liable for incidents resulting from faulty or non-existent earthing. • H4000 Heliotherme and TPL4000 Destratifier: - Direct connection to AC Single-Phase and AC Three-Phase fan motor assembly...
  • Page 13: Powering Up

    9 - POWERING UP At system start-up: • Remove the bridge on the terminal block (see "Motor connection" diagram 7168208). • Ensure that the motor rotates in the right direction (see marking indicating the fan's normal direction of rotation). • Measure the current consumed by the motor: - If this is equal to or less than the current indicated on the unit's data plate, the installation is in good working order.
  • Page 14: Tests And Warranty

    Under no circumstances must the fitter carry out work on the motor. This will invalidate any future claims on the warranty. CIAT's  products  carry  the  CE  mark,  allowing  them  to  be  sold  throughout  the  European  Union.  This  mark  is  your ...
  • Page 15: Control Units

    You can view the operating status of your HELIOTHERME or DESTRATIFIER unit individually (fresh air or return air, motor fault, risk of frost etc.) Refer to the instruction manual supplied in the packaging of your Eco+ 3-PH BOX box for further information or contact your CIAT agent.
  • Page 16 Plug & Play solution • A remote on/off control is available as well as a two separate fault summaries. Possibility to communicate via ModBus, JBUS  or Bacnet IP. Networked solution Refer to the instruction manual supplied in the packaging of your HEE 1-PH BOX for further information or contact your CIAT agent. 3-speed HEE THERMOSTAT • Functions The HEE control includes a temperature selector (range from 10°C to 30°C) that maintains the room temperature at the selected value.
  • Page 17: Wall Bracket

    15 - WALL BRACKET Diagram 7192990 I BIS filter box 820.5 FRONT view Support supplied by CIAT Connection diameter Drain sleeve in COOLING mode, outer diameter 32 mm Model Connection diameter H4300 G 1/2" union H4350 G 3/4" union H4400 G 3/4" union H4450 G 1" union H4500 G 1"...
  • Page 18: Filter Box

    16 - FILTER BOX Assembly procedure: 1. Remove the galvanised mesh filter to facilitate handling. 2. Remove the 4 x M8 screws found at the ends of the heliotherme. 3. Fit the filter box in position on the unit. 4. Refit the 4 x M8 screws in their original positions to secure the filter box in place. 5.
  • Page 19: Diffuser On Door

    17 - DIFFUSER ON DOOR Assembly procedure: 1. Remove the double deflection grille fitted as standard on the Heliotherme if it is present 2. Remove the CBLX 4.85x14.5 screws (A) which secure the guard plate (B) on the diffuser (C) 3. Place the diffuser support against the Heliotherme and secure it using the CBLX screws supplied (D) 4. Refit the guard plate (B) and secure it with the CBLX screws (A) Diffuser on door Diffuser on door...
  • Page 20: Diffuser For Large Spaces

    18 - DIFFUSER FOR LARGE SPACES Assembly procedure: 1. Remove the double deflection grille fitted as standard on the Heliotherme if it is present 2. Remove the 6 CBLX 4.85x14.5 screws (A) which secure the grille (B) on the support (C) 3. Place the diffuser support against the Heliotherme and secure it using the CBLX screws supplied (D) 4. Refit the grille (B) and secure it with the CBLX screws (A) 5.
  • Page 21: Final Shutdown

    • At the end of its life, this equipment must be disassembled and contaminated fluids removed by professionals and processed  via approved channels for electrical and electronic equipment (WEEE). - In France, CIAT has formed a partnership with ECOLOGIC for the collection and recovery of professional waste governed  by European Directive WEEE 2012/19/EU. This partnership simplifies the mandatory administrative procedures and ensures that old equipment is recovered via an official, structured channel. In terms of renovation work in France (mainland and overseas), for every CIAT unit installed, our partner will collect and dismantle your existing equipment (see ...