2-SPEED MOTORS — HIGH SPEED START SCHEMATIC
DIAGRAMS AND RECONNECTION INSTRUCTIONS FOR
CAPACITOR
NOTE:
Several different connections have been used in production. If the wiring on the
motor you are reconnecting does not match these diagrams contact A.O. Smith and
we will FAX or mail a connection for that model.
RECONNECTION FOR REMOTE SWITCH OPERATION
DISCONNECT PURPLE AND YELLOW
LEADS FROM HI-LOW SWITCH AND
CONNECT TOGETHER.
DISCONNECT BLACK TRACER LEAD
FROM HI-LOW SWITCH PERMANENT-
LY . TAPE UPEXPOSED END.
CONNECT POWER SUPPLY LINES TO
TERMINALBOARD
L2-L1
HIGH SPEED
L2-A
LOW SPEED
Level 2
REMOTE OPERATION
2-Speed with Hi - Low Switch
Mounted in External Box
START
YELLOW
SWITCH BOX
YELLOW
Pump Motors
BLACK
L 2
B
BLACK TRACER
A
PURPLE
L 1
COMMON