2-Speed Motors Hi-Low Switch Reconnection - A.O. Smith ST1302 Manual

Pump motors
Table of Contents

Advertisement

Pump Motors
2-SPEED MOTORS — HIGH SPEED START SCHEMATIC
DIAGRAMS AND RECONNECTION INSTRUCTIONS FOR
REMOTE OPERATION
2-Speed with Hi - Low Switch
Mounted on Motor Canopy
BLACK
RED
START
CAPACITOR
RED
BLACK
HI
PURPLE
LOW
CANOPY SWITCH
YELLOW
YELLOW MUST BE CONNECTED
TO BOTTOM TERMINAL WITH
SWITCH IN POSITION SHOWN
NOTE:
Several different connections have been used in production. If the wiring on the
motor you are reconnecting does not match these diagrams contact A.O. Smith and
we will FAX or mail a connection for that model.
RECONNECTION FOR REMOTE SWITCH OPERATION
REMOVE BOTH YELLOW LEADS
FROM 'A' TERMINALAND CONNECT
TO TERMINALL1.
REMOVE BLACK LEAD FROM HI-LOW
SWITCH AND CONNECT IT TO
TERMINALA.
LEAVE SWITCH IN CANOPYAND
LEAVE PURPLE LEAD CONNECTED
TO SWITCH.
CONNECT POWER SUPPLY LINES TO
TERMINALBOARD
L2-L1
HIGH SPEED
L2-A
LOW SPEED
BEFORE REPLACING MOTOR
CANOPY, BE SURE ALLLEADS ARE
PROPERLY PLACED TO PREVENT
DAMAGE FROM GOVERNOR AND/OR
CANOPY.
Level 2
WHITE
LINE VOLTS
START
- X & Y CLOSED Z OPEN
RUN
- X & Y OPEN
HI-LOW SWITCH
YELLOW
Z CLOSED
PURPLE
A.O.Smith
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt1072

Table of Contents