Do not install on or behind ceiling beams if they
are thicker than 20 cm.
1d
Install at a distance of at least 50 cm from fluorescent light sources.
1e
Dining room
Living room
Installation sites for smoke detectors in single storey 2 bedroom flat.
Smoke detector for
minimum safety
50 cm
50 cm
Kitchen
Bedroom
Bedroom
Hallway
Smoke detector for added
safety
2.
Installation
2a
Protect device from dust caused by drilling.
2b
1
The installation lock
ensures that the device cannot be installed without
1
the battery. If the battery is correctly connected, the LED
approximately every 45 seconds. Carry out a test to ensure that it is
functioning correctly.