Norsat ATOM Series Operator's Manual

Norsat ATOM Series Operator's Manual

Hide thumbs Also See for ATOM Series:
Table of Contents

Advertisement

Quick Links

ATOM Ku BUC/SSPA
Revision A
20W/25W/40W/50W
908239
ATOM Ku
BUC/SSPA
20W/25W/40W/50W
Operator Manual
Document Number: 908239
Revision A
Norsat International Inc.
110 – 4020 Viking Way
Richmond, British Columbia
Canada V6V 2L4
1
908239_rA - Operator Manual ATOM KU 20-
25-40-50W

Advertisement

Table of Contents
loading

Summary of Contents for Norsat ATOM Series

  • Page 1 ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 ATOM Ku BUC/SSPA 20W/25W/40W/50W Operator Manual Document Number: 908239 Revision A Norsat International Inc. 110 – 4020 Viking Way Richmond, British Columbia Canada V6V 2L4 908239_rA - Operator Manual ATOM KU 20- 25-40-50W...
  • Page 2 Norsat does not assume any liability arising out of the application or use of any product or circuit described herein. Norsat does not convey any license under its patent rights or the rights of others.
  • Page 3: Copyright Notice

    Copyright © 2016. Norsat International Inc. All rights reserved. All materials contained in this user guide are the property of Norsat International Inc. except as noted here below: All materials in this user guide are protected by United States and international copyright laws. The compilation of all content in this user guide is the exclusive property of Norsat.
  • Page 4 20W/25W/40W/50W 908239 Support Technical Support This manual provides engineers with information necessary to operate the applicable system. Technical Support is available from Norsat. Norsat International Inc. Attn: Technical Support 110 – 4020 Viking Way Richmond, BC Main: 1 (604) 821-2800 Support: 1 800 644 4562 sat.support@norsat.com...
  • Page 5 ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 REVISION HISTORY CO No. Reason For Change Reviewed Author Date yyyy/mm/dd 5521 Initial Release BPetrovic Florence Leung 2013/11/14 Add details on screw 5764 lengths for RF Output JGlassford Florence Leung 2014/04/29 and Ground Connection 5964 Update Address Florence Leung...
  • Page 6: Table Of Contents

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 TABLE OF CONTENTS COPYRIGHT NOTICE ..........................3 CHAPTER 1 INTRODUCTION ........................8 1.1 O ..........................8 ECTION VERVIEW BUC - Block Up Converter and Amplifier ......................8 SSPA – Solid State Power Amplifier ........................8 1.2 F ..........................
  • Page 7 ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 FIGURES Figure 2-1: J2 Connector Pin Out, Viewed Looking at SSPA/BUC from the Outside ..........13 Figure 2-2: Setup Serial Port ............................15 Figure 2-3: Command getident............................ 16 Figure 2-4: Command getstatus ..........................16 Figure 2-5: Command getfaults ...........................
  • Page 8: Chapter 1 Introduction

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Chapter 1 Introduction Section 1.1 VERVIEW This User’s Guide covers the following product lines: ATOMSKU020, ATOMSKU025, ATOMSKU040, ATOMSKU050 ATOMBKU020, ATOMBKU025, ATOMBKU040, ATOMBKU050 BUC - B LOCK ONVERTER AND MPLIFIER If this unit is a BUC, this unit converts IF to RF in the KU range for the frequencies specified in the original configuration of this unit and amplifies the power to the specified power.
  • Page 9: Section 1.2 Features

    Waveguide WR75 (default) Waveguide WR62 (Adaptors are available to convert output type to SMA, TNC, or N-Type connectors. Please contact Norsat for more information.) LECTRICAL NTERFACE M&C Connector – ten pin connector used to interface to a host computer. See...
  • Page 10: Section 1.3 Cautions And Warnings

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Section 1.3 AUTIONS AND ARNINGS CAUTION: Do not stand in front of waveguide during operation. Especially, do not look into the waveguide. CAUTION: Do not allow any items to fall into the unit from the waveguide opening. WARNING: DO NOT ALLOW EQUIPMENT TO BE IN STANDING WATER.
  • Page 11: Chapter 2 Installation And Interfaces

    Other arrangements are possible depending on the requirements of the application; please contact Norsat technical support for details. Please leave at least 1 inch of clearance around the fan air intakes.
  • Page 12: J1 - Input

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Section 2.3 J1 – I NPUT The IF input is a 50 ohm type-N connector. The input is to be applied here (950-1700 MHz for Extended Band; 950-1450 MHz for Regular Band). Also, the 10 MHz signal input is diplexed onto this line. Therefore, the IF signal and 10 MHz reference are both traveling on this line.
  • Page 13: Pin D: Shutdown (I.e. Mute Control)

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 The pin outs are given in Table 2-1 and shown in Figure 2-1. Table 2-1: J2 Pin Outs Connector Pin Function Description TX- (RS-485) Host computer TX- signal (signal into unit) TX+ (RS-485) Host computer TX+ signal (signal into unit) RX+ (RS-485) Host computer RX+ signal (signal out of unit)
  • Page 14: Pin G: Gnd

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Pin D is also configurable to be either active high or active low. When configured as active high, any voltage between 3.0 V and 5.0 V (relative to case ground) will mute the output. When configured as active low, any voltage between 0.0 V and 0.8 V (relative to case ground) will mute the output.
  • Page 15: Serial Port Software Interface

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Section 2.5 ERIAL OFTWARE NTERFACE Communications to and from the serial interface is character based. Use any standard “Terminal” program with setup parameters as shown in Figure 2-2. Figure 2-2: Setup Serial Port ONTROLLER ESPONSES The unit will only generate messages in response to a command.
  • Page 16: Message Definitions

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 ESSAGE EFINITIONS getident This command returns the part number, software revision and serial number of the unit. Figure 2-3: Command getident getstatus This command instructs the unit to respond with fault flag, forward power and temperature. Note: reverse power, “revpwr”, in the response is a future enhancement and is not currently supported.
  • Page 17: Figure 2-5: Command Getfaults

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 getfaults This command gets the status of the mute, over temperature and pll loss of lock. For mute, “0” indicates the unit is in an unmuted state. A “1” indicates a muted state. Note that a “1” does not necessarily indicate an error as the unit could have been commanded into a mute state (see “setmute”...
  • Page 18: Command Response

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 setmute This command sets the software mute state of the unit. If the command code is 1, the amplifier will be muted. If the command code is 0, the amplifier mute will be controlled as shown in Section Mute Logic.
  • Page 19: Mute Logic

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Each command response will have the following format: <CR><LF><msg><CR><LF> where msg is as described above and in the commands summary and example tables below. Note that a response is enveloped by leading and trailing <CR><LF> characters. Table 2-3: Commands Summary Command Param-Value...
  • Page 20: J3 - Dc Power

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Section 2.6 J3 – DC P OWER Units typically require 20V to 56V DC power. Refer to the specific configuration of the unit for the exact voltage range. Power is supplied through a four pin type cannon connector. Two pins are used to deliver the positive connection and two pins are used for the negative connection in order to reduce resistance.
  • Page 21: J3 Connector Pin Outs

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 J3 C ONNECTOR Figure 2-9: J3 Connector Pin Out, Viewed Looking at SSPA/BUC from the Outside 908239_rA - Operator Manual ATOM KU 20- 25-40-50W...
  • Page 22: J4 - Rf Output

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Table 2-4: J3 Connector Pin Out Name Ground or V- Ground or V- Positive voltage is applied to pins B and C (connected internally). Negative voltage is applied to pins A and D (connected internally). Pins A and D are connected internally to case ground.
  • Page 23: Emc Considerations

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Section 2.9 EMC C ONSIDERATIONS For optimal EMC performance the following are recommended: • Use a high quality DC cable that’s shielded, grounded at both ends and not longer than necessary for the application. •...
  • Page 24: Appendix A Mechanical Drawings

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Appendix A Mechanical Drawings – 20W RAWINGS Figure A- 1: 20W and 25W Interconnect Locations 908239_rA - Operator Manual ATOM KU 20- 25-40-50W...
  • Page 25: Figure A- 2: 20W And 25W Ku Sspa/Buc Assembly, Without Fans

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Figure A- 2: 20W and 25W KU SSPA/BUC Assembly, without Fans 908239_rA - Operator Manual ATOM KU 20- 25-40-50W...
  • Page 26: Figure A- 3: 20W And 25W Base Plate Mounting Locations

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Figure A- 3: 20W and 25W Base Plate Mounting Locations 908239_rA - Operator Manual ATOM KU 20- 25-40-50W...
  • Page 27: Drawings - 40W And 50W

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 – 40W RAWINGS Figure A- 4: 40W and 50W KU SSPA/BUC Assembly, with Fans 908239_rA - Operator Manual ATOM KU 20- 25-40-50W...
  • Page 28: Figure A- 5: 40W And 50W Ku Sspa/Buc Assembly, Without Fans

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Figure A- 5: 40W and 50W KU SSPA/BUC Assembly, without Fans 908239_rA - Operator Manual ATOM KU 20- 25-40-50W...
  • Page 29: Figure A- 6: 40W And 50W Ku Sspa/Buc Assembly, With Fans And Emc/Emi Filter Option

    ATOM Ku BUC/SSPA Revision A 20W/25W/40W/50W 908239 Figure A- 6: 40W and 50W KU SSPA/BUC Assembly, with Fans and EMC/EMI Filter Option 908239_rA - Operator Manual ATOM KU 20- 25-40-50W...
  • Page 30: Appendix B Acronyms And Abbreviations

    ATOM Ku BUC/SSPA Revision 1.4 20W/25W/40W/50W 908239 Appendix B Acronyms and Abbreviations The following is a list of acronyms and abbreviations referenced in this document. Acronym Definition Block Upconverter Amplifier Celsius Decibel-milliwatts Direct Current Electromagnetic Compatibility Electrostatic Discharge freq Frequency Gigahertz Ground Intermediate Frequency...

Table of Contents