Handling Instruction - phytron LSS 26 Manual

In-vacuum stepper motors, cryo motors
Table of Contents

Advertisement

WARNING – Injury from touching the housing!
Stepper motors heat up during operation. The surface of the motor can be
heated over +100 °C.
-
The motor must be mounted in such way that proper dissipation of
the generated heat is ensured.
-
Wait until the stepper motor has completely cooled down.
-
Ensure measures for contact protection

1.3 Handling instruction

CAUTION – Possible damage!
i
The stepper motor's rotor is strongly magnetic. Metal or soft iron particles
penetrating through the large outgassing holes might damage motor func-
tion.
-
Metal particles must be kept away from the motor.
CAUTION – Possible damage!
i
Foreign substances, dirt or humidity penetrating through the outgassing
holes could seriously damage motor function or cause breakdown.
-
Do not touch the stepper motor with bare hands. Wear security
gloves
-
Handle the in-vacuum stepper motor/cryo stepper motor only in a
very clean environment!
MA 1203-A010 EN
7
phytron