Download Print this page

Samsung CS7202NBX/EIS Service Manual page 13

Chassis: sct12b

Advertisement

4-2-3 Test Pattern (Aging Mode)
1. This mode can be used during servicing, or for confirming that
the convergence and purity adjustments are correct.
2. Access the Test Pattern parameters by pressing a CHANNEL
keys ( , ) while the Service Mode is on. The cursor will move
to the test pattern. Press the VOLUME keys. On-screen display:
o RED
o GREEN
o BLUE
3. AGING Mode (Reference Only)
This pattern is used for pre-heating the CRT during
manufacturing--it is accessed in the factory by twice pressing the
"HIDDEN" key .
Even if the TV power is cut off, the Aging Mode is not cancelled,
The patterns are displayed at 5 sec intervals. The AGING mode
is cancelled by repressing the "HIDDEN" key.