Honeywell KXP2290 Alignment Procedure page 7

Diversity mode s transponder
Hide thumbs Also See for KXP2290:

Advertisement

UUT Initial Set Up:
Use the Diagnostic Utility program to initialize the UUT to be Aligned.
1.
Double-click on the Icon of the previously installed Diagnostic Utility
program.
2.
Set +28 volt Power Supply to "ON" position.
3.
Set Test Panel Aircraft Power switch to "ON" position.
4.
Be sure the correct revision of Boot, Application and Firmware are
loaded. The Diagnostic Utility program will display this information.
5.
Set MODE S ADDRESS to "52525252" (Octal) or
"AAAAAA" (Hex)
6.
Set 4096 CODE to "7777"
7.
Set MAX AIR SPEED to "75-150"
8.
Set OPERATIONAL MODE to "Altitude"
9.
Set AIRBORN/GROUND to "Airborne"
10.
Set DIVERSITY to "Enable"
11.
CYCLE AIRCRAFT POWER
12.
Set SQUITTER to "Disable"
Honeywell International Inc.
KXP2290 Diversity Mode S Transponder
Alignment Procedure
HONEYWELL CONFIDENTIAL
001-05117-0010
Revision -