IDEC KW2D Series User Manual page 58

Rfid reader
Hide thumbs Also See for KW2D Series:
Table of Contents

Advertisement

Chapter 4 KW RFID Configurator
(3) Connection Settings
Sets the connections to use for the KW2D Series RFID Reader. The port numbers used in Ethernet communication by the KW2D
Series RFID Reader and the assigned communication modes are as follows.
502
503
504
2101
2102
(4) Password Settings
Download Password
Upload Password
Manage the passwords appropriately so that third parties do not know them. If you forget the download password, use the
[Reset RFID Reader to factory settings] function in the KW RFID Configurator to reset the RFID reader. The project saved in the
KW2D Series RFID Reader will be deleted and the settings will be reset to the factory settings.
For details, see "[Reset RFID Reader to factory settings] Dialog Box" on page 4-13.
4-18
: "ModbusTCP Server" is the assigned communication mode.
To restrict access to the KW2D Series RFID Reader, select the [Restrict] check box, and then enter the IP
address from which access is allowed in the [Allow Access by IP Address] field.
: "ModbusTCP Server(Maintenance)" is the assigned communication mode.
To restrict access to the KW2D Series RFID Reader, select the [Restrict] check box, and then enter the IP
address from which access is allowed in the [Allow Access by IP Address] field.
Select "Unused" or "ModbusTCP Server(Maintenance)" for the communication mode.
If "ModbusTCP Server(Maintenance)" is selected, access to the KW2D Series RFID Reader can be
restricted. To restrict access to the KW2D Series RFID Reader, select the [Restrict] check box, and then
enter the IP address from which access is allowed in the [Allow Access by IP Address] field.
: "Maintenance Communication Server" is the assigned communication mode.
: Select "Unused" or "Maintenance Communication Server" for the communication mode.
: Select this check box to password protect downloading the project to the KW2D Series RFID Reader.
Download Password
Download Password(Confirm)
: Select this check box to password protect uploading the project from the KW2D Series RFID Reader.
Upload Password
Upload Password(Confirm)
KW2D Series RFID Reader User's Manual
KW9Y-B2163
: Enter the password. The entered characters are masked with *
(asterisks).
The length of the password is 8 to 16 characters. Only single-byte
alphanumeric characters and symbols can be used.
The password can be set only when the [Download Password]
check box is selected.
: Enter the same password that you entered in [Download
Password].
: Enter the password. The entered characters are masked with *
(asterisks).
The length of the password is 8 to 16 characters. Only single-byte
alphanumeric characters and symbols can be used.
The password can be set only when the [Upload Password]
check box is selected.
: Enter the same password that you entered in [Upload Password].

Advertisement