Attention: In case of damages or wear it is necessary to change the whole
device including its actuator. Correct operation cannot be guaranteed when the device
is deformed or damaged.
- The installer is responsible for establishing the sequence of functional tests to which
the device is to be subjected before the machine is started up and during maintenance
intervals.
- The sequence of the functional tests can vary depending on the machine complexity
and circuit diagram, therefore the functional test sequence detailed below is to be
considered as minimal and not exhaustive.
- Perform the following sequence of checks before the machine is commissioned and
at least once a year (or after a prolonged shutdown):
1) Open the guard while the machine is moving. The machine must stop immediately.
The stopping time of the machine must be always shorter than the time required by the
operator for opening the guard and reaching the dangerous parts.
2) Try to start the machine while the guard is open. The machine must not start.
3) Check correct actuator to device alignment.
4) All external parts must be undamaged.
5) If the device is damaged, replace it completely.
6) The actuator must be securely locked to the door; make sure that none of the
machine operator's tools can be used to disconnect the actuator from the door.
- The device has been created for applications in dangerous environments, therefore
it has a limited service life. Although still functioning, after 20 years from the date
of manufacture the device must be replaced completely. The date of manufacture is
placed next to the product code (see paragraph MARKINGS).
6.5 Wiring
Attention: Check that the supply voltage is correct before powering the device.
In particular, make sure that the supply current does not exceed the values indicated
in the TEChNICAL DATA paragraph; high currents can cause safety device failures or
malfunctions.
The safety device may be used exclusively with resistive loads. The use of inductive
loads can lead to the loss of the safety function.
- Keep the charge within the values specified in the electrical operation categories.
- Only connect and disconnect the device when the power is off.
- Do not open the device for any reason.
- Discharge static electricity before handling the product by touching a metal mass
connected to earth. Any strong electrostatic discharge could damage the device.
- Power the safety sensor and the other devices connected to it from a single SELV
source and in accordance with the applicable standards.
- Always connect the protection fuse (or equivalent device) in series to the safety
electrical contacts.
- During and after the installation do not pull the electrical cables connected to the
device.
- For devices with integrated cable, the free end of the cable (if it does not have a
connector) must be properly connected inside a protected housing. The cable must be
adequately protected from cuts, impacts, abrasion, etc.
6.6 Additional prescriptions for safety applications with operator protection
functions
Provided that all previous requirements for the devices are fulfilled, for installations
with operator protection function additional requirements must be observed.
- The utilization implies knowledge of and compliance with following standards:
EN 60947-5-3, EN ISO 13849-1, EN 62061, EN 60204-1, EN ISO 14119,
EN ISO 12100.
6.7 Limits of use
- Use the device following the instructions, complying with its operation limits and the
standards in force.
- The devices have specific application limits (min. and max. ambient temperature,
mechanical endurance, IP protection degree, etc.). These limitations are met by the
device only if considered individually and not as combined with each other.
- The manufacturer's liability is to be excluded in the following cases:
1) Use not conforming to the intended purpose;
2) Failure to adhere to these instructions or regulations in force;
3) Fitting operations not carried out by qualified and authorized personnel;
4) Omission of functional tests.
- For the cases listed below, before proceeding with the installation contact our techni-
cal assistance service (see paragraph SUPPORT):
a) In nuclear power stations, trains, airplanes, cars, incinerators, medical devices or
any application where the safety of two or more persons depend on the correct opera-
tion of the device;
b) Applications not contemplated in this instruction manual.
7 MARKINGS
The outside of the device is provided with external marking positioned in a visible
place. Marking includes:
- Producer trademark
- Product code
- Batch number and date of manufacture. Example: A18 SR1-123456. The batch's first
letter refers to the month of manufacture (A=January, B=February, etc.). The second
and third letters refer to the year of manufacture (18 = 2018, 19 = 2019, etc...).
8 TECHNICAL DATA
8.1 Housing
housing made of glass fibre reinforced technopolymer, self-extinguishing.
Versions with integrated cable 4 x 0.34 mm
Protection degree:
8.2 General data
Assured operating distance S
:
ao
Assured release distance S
:
ar
or 6 x 0.25 mm
, M8 or M12 connector
2
2
IP67 acc. to EN 60529
IP69K acc. to ISO 20653
(Protect the cables from direct high-pressure and
high-temperature jets)
5 mm with actuator SM A01N
15 mm with actuator SM A01N
Repeat accuracy:
Switching frequency:
Distance between two sensors:
SIL level (SIL CL):
Performance Level (PL):
Safety category:
* By connecting a single dual channel sensor to a Pizzato safety module
Interlock, no contact, coded:
Coding level:
B10
per channel:
d
Mission time:
Ambient temperature:
Storage temperature:
Vibration resistance:
Shock resistance:
Pollution degree:
Screw tightening torque:
8.3 Electrical data
Rated insulation voltage U
:
i
Rated impulse withstand voltage U
Thermal current I
:
th
Maximum switching load:
Rated operating voltage U
:
e
Rated operating current I
:
e
Protection fuse:
Electrical endurance:
8.4 Compliance with standards
EN 60947-1:2007 + A1:2011 + A2:2014, EN 60947-5-1, EN 60947-5-2,
EN 60947-5-3:2013 (in combination with a safety module), EN ISO 14119:2013, EN
ISO 12100, EN ISO 13849-1:2015, EN ISO 13849-2, EN 62061:2005 + A1:2012 +
A2:2015, EN 60204-1, EN 60529, EN 61508-1:2010, EN 61508-2:2010,
EN 61508-4:2010, EN 50581, ISO 20653, UL 508, CSA 22.2 No.14
8.5 Compliance with directives
Machinery Directive 2006/42/CE, EMC Directive 2014/30/UE, RohS Directive
2011/65/UE.
9 SPECIAL VERSIONS ON REQUEST
Special versions of the device are available on request.
The special versions may differ substantially from the indications in this instruction
sheet.
The installer must ensure that he has received written information from the support
service regarding installation and use of the special version requested.
10 DISPOSAL
At the end of service life product must be disposed of properly, according to the
rules in force in the country in which the disposal takes place.
11 SUPPORT
The device can be used for safeguarding people's physical safety, therefore in case of
any doubt concerning installation or operation methods, always contact our technical
support service:
Pizzato Elettrica Srl
Via Torino, 1 - 36063 Marostica (VI) - Italy
Telephone +39.0424.470.930
E-mail tech@pizzato.com
www.pizzato.com
Our support service provides assistance in Italian and English

12 EC CONFORMITY DECLARATION

I, the undersigned, as a representative of the following manufacturer:
Pizzato Elettrica Srl, Via Torino, 1 - 36063 Marostica (VI) - Italy
hereby declare that the product is in conformity with whatever prescribed by the
2006/42/EC Machine Directive. The complete version of the present conformity
declaration is available on our website www.pizzato.com
Marco Pizzato
DISCLAIMER:
Subject to modifications without prior notice and errors excepted. The data given in this sheet
are accurately checked and refer to typical mass production values. The device descriptions and
its applications, the fields of application, the external control details, as well as information on
installation and operation, are provided to the best of our knowledge. This does not in any way mean
that the characteristics described may entail legal liabilities extending beyond the "General Terms of
Sale", as stated in the Pizzato Elettrica general catalogue. Customers/users are not absolved from
the obligation to read and understand our information and recommendations and pertinent technical
standards, before using the products for their own purposes. Taking into account the great variety of
applications and possible connections of the device, the examples and diagrams given in the present
manual are to be considered as merely descriptive; the user is deemed responsible for checking that
the specific application of the device complies with current standards. This document is a translation
of the original instructions. In case of discrepancy between the present sheet and the original copy,
the Italian version shall prevail. The present manual may not be reproduced, in whole or in part,
without the prior written permission by Pizzato Elettrica.
© 2018 Copyright Pizzato Elettrica. All rights reserved.
6/12
≤ 10%
up to 150 hz
minimum 50 mm
Up to SIL 3 acc. to EN 62061*
Up to PL e acc. to EN ISO 13849-1*
up to cat. 4 acc. to EN ISO 13849-1*
type 4 acc. to EN ISO 14119
low acc. to EN ISO 14119
20,000,000
(used with Pizzato safety modules)
400,000
(used with max load DC12: 24 V 0.25 A)
20 years
-25°C ... +80°C
-25°C ... +80°C
10 gn (10...150 hz) acc. to EN 60068-2-6
30 gn; 11 ms acc. to EN 60068-2-27
3
0.8 ... 2 Nm
120 Vac (with cable)
60 Vac / 75 Vdc (with M8 connector)
120 Vac (with M12 connector, 4-pole)
30 Vac / 36 Vdc (with M12 connector, 8-pole)
: 6 kV / 1.5 kV (with connector)
imp
0.25 A
6 W (resistive load)
24 Vac/dc
0.25 A (resistive load)
0.25 A type F
1 million operating cycles